Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-370NE09RC05 — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-370NE09RC05 is a 370.0 W STC (347.3 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 18.69% efficiency, 47.1 V Voc at 25 C, and 51.25 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
370.0 W
PTC Wattage
347.3 W
Voc @ 25C
47.1 V
Efficiency
18.69%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-370NE09RC05 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Trina Solar TSM-370NE09RC05 (Mono-c-Si) residential solar systems.

Homeowners evaluating Trina Solar TSM-370NE09RC05 need 17 panels for 6 kW or 22 panels (469 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (469 sq ft). Under NEC 690.7(A), beta_Voc (-0.252%/C) pushes open-circuit voltage to 51.25 V at 14 F and 52.44 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Trina Solar TSM-370NE09RC05 Fall Across Listed CEC Models?

Comparison of Trina Solar TSM-370NE09RC05 (370.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-370NE09RC05 (370.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-37: 370.0 W

What Dataset Percentiles Define Trina Solar TSM-370NE09RC05?

Relative ranking of Trina Solar TSM-370NE09RC05 across nameplate watts, 93.9% PTC thermal ratio, and module aperture efficiency. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Trina Solar TSM-370NE09RC05 Engineering BenchmarksPercentile comparison of Trina Solar TSM-370NE09RC05 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage370.0 WPTC/STC Retention93.9%Module Efficiency18.69%

What Do the Dataset Ranks Show for Trina Solar TSM-370NE09RC05?

Summary of Trina Solar TSM-370NE09RC05 output rank, 8 kW array size (22 panels), efficiency rating, and 600 V string limit.

Rank #11,697 / 21,677

370.0 W STC · Higher Than 44.4%

370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,033

18.69% Aperture Efficiency

Power density 186.9 W/m2 (1.22 percentage points below 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.25 V at -10 C (563.8 V string) and 52.44 V at -20 C (11 max).

8 kW Reference Array

22 Panels = 8,140 W STC

Occupies 43.6 m2 (469 sq ft) producing 7,641 W PTC; NEC 690.8 OCPD floor is 15.74 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.1 * (1 + (-0.252/100) * (-10 - 25)) = 51.25 V | OCPD = 1.56 * 10.09 = 15.74 A

Inputs from CEC Modules.csv for Trina Solar TSM-370NE09RC05: Voc=47.1 V, beta_Voc=-0.252%/C, Isc=10.09 A, STC=370.0 W, Area=1.98 m2.

Result: 11 panels max on 600 V (563.8 V); 22 panels for 8 kW (469 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-370NE09RC05?

Complete CEC test sheet for Trina Solar TSM-370NE09RC05 including Isc (10.09 A), Voc (47.1 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-370NE09RC05.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 370.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 347.3 W (93.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.09 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.1 V / 9.47 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.252 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.69% (1.98 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-370NE09RC05 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Trina Solar TSM-370NE09RC05.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.29 kW 362 sq ft $1,574 $2,662
8 kW Class 22 8.14 kW 469 sq ft $2,037 $3,445
10 kW Class 28 10.36 kW 597 sq ft $2,593 $4,385

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Related Trina Solar power steps and black/silver trims consolidated into this Trina Solar TSM-370NE09RC05 series guide. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Sibling CEC listings grouped into the Trina Solar TSM-370NE09RC05 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-365NE09RC05 365.0 W 342.5 W 47.1 V 38.7 V 18.43%
Trina Solar TSM-370NE09RC05 370.0 W 347.3 W 47.1 V 39.1 V 18.69%

How Many Trina Solar TSM-370NE09RC05 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Trina Solar TSM-370NE09RC05 (47.1 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=47.1V and beta_Voc=-0.252%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.44 V 11 panels 576.8 V 19 panels
-10 C (14 F) 51.25 V 11 panels 563.8 V 19 panels
0 C (32 F) 50.07 V 11 panels 550.8 V 19 panels
25 C (77 F STC) 47.1 V 12 panels 565.2 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-370NE09RC05?

Four comparable CEC modules such as CertainTeed CT370M00-04 (370.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CT370M00-04
CertainTeed
370.0 W Tie (0 W) 47.9 V 19.66% 93.2%
Bluesun Solar Energy Tech CoLtd BSM370M-72
Bluesun Solar Energy Tech CoLtd
370.0 W Tie (0 W) 48.23 V 19.07% 91.9%
AXITEC AC-365MH/144S
AXITEC
365.0 W -5.0 W 47.21 V 18.4% 92.7%
AXITEC AC-365MH/144V
AXITEC
365.0 W -5.0 W 47.21 V 18.4% 92.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-370NE09RC05?

Evaluate Trina Solar TSM-370NE09RC05 (370.0 W STC, 47.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-370NE09RC05 reaches 52.44 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 469 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (469 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-370NE09RC05 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-370NE09RC05 8 kW Residential Fit

Needs 22 modules (469 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CertainTeed CT370M00-04.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 347.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-370NE09RC05 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Trina Solar TSM-370NE09RC05 PTC wattage (347.3 W) lower than STC (370.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 347.3 W PTC (93.9% retention) across Trina Solar TSM-370NE09RC05's 1.98 m2 aperture.

Who should skip Trina Solar TSM-370NE09RC05 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 22 Trina Solar TSM-370NE09RC05 panels (469 sq ft) leave unusable roof gaps vs. CertainTeed CT370M00-04.

What is the 1,000 V commercial string limit for Trina Solar TSM-370NE09RC05?

On 1,000 V commercial inverters at -10 C (51.25 V cold Voc), Trina Solar TSM-370NE09RC05 fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-370NE09RC05.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.