AXITEC AC-365MH/144S is a 365.0 W STC (338.4 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 18.4% efficiency, 47.21 V Voc at 25 C, and 51.75 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 365.0 W
- PTC Wattage
- 338.4 W
- Voc @ 25C
- 47.21 V
- Efficiency
- 18.4%
How Does AXITEC AC-365MH/144S Compare Against Peer CEC Listings?
Engineering position of AXITEC AC-365MH/144S (365.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612M-365-H across 5,889 CEC Mono-c-Si solar modules.
Ranking #12,044 across 21,677 CEC solar panels (below all-CEC median; higher than 42.9% of peers), AXITEC AC-365MH/144S operates as a compact residential or specialty off-grid module sitting 45.0 W below the 410.0 W Mono-c-Si median. Mid-range 47.21 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677), 22 panels occupy 470 sq ft and offset roughly $2,010/yr at average US rates (or $3,398/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does AXITEC AC-365MH/144S Fall Across Listed CEC Models?
Plots AXITEC AC-365MH/144S at 365.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define AXITEC AC-365MH/144S?
Benchmarks AXITEC AC-365MH/144S on STC wattage, thermal PTC/STC retention, and 18.4 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for AXITEC AC-365MH/144S?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for AXITEC AC-365MH/144S by AXITEC.
365.0 W STC · Higher Than 42.9%
365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.4% Aperture Efficiency
Power density 184.0 W/m2 (1.51 percentage points below 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.75 V at -10 C (569.2 V string) and 53.05 V at -20 C (11 max).
22 Panels = 8,030 W STC
Occupies 43.6 m2 (470 sq ft) producing 7,445 W PTC; NEC 690.8 OCPD floor is 15.24 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.21 * (1 + (-0.275/100) * (-10 - 25)) = 51.75 V | OCPD = 1.56 * 9.77 = 15.24 A
Inputs from CEC Modules.csv for AXITEC AC-365MH/144S: Voc=47.21 V, beta_Voc=-0.275%/C, Isc=9.77 A, STC=365.0 W, Area=1.984 m2.
Result: 11 panels max on 600 V (569.2 V); 22 panels for 8 kW (470 sq ft).
What Are the Published CEC Specifications for AXITEC AC-365MH/144S?
Laboratory test ratings recorded for AXITEC AC-365MH/144S (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 365.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 338.4 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.21 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.77 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.39 V / 9.27 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.275 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.4% (1.984 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-365MH/144S Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (470 sq ft at 8 kW), and estimated Year-1 electric bill offset for AXITEC AC-365MH/144S.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.21 kW | 363 sq ft | $1,554 | $2,628 |
| 8 kW Class | 22 | 8.03 kW | 470 sq ft | $2,010 | $3,398 |
| 10 kW Class | 28 | 10.22 kW | 598 sq ft | $2,558 | $4,325 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
Sibling wattage bins and frame colors grouped with AXITEC AC-365MH/144S under AXITEC to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-355MH/144S | 355.0 W | 328.9 W | 46.82 V | 39.01 V | 17.89% |
| AXITEC AC-360MH/144S | 360.0 W | 333.7 W | 47.01 V | 39.2 V | 18.15% |
| AXITEC AC-365MH/144S | 365.0 W | 338.4 W | 47.21 V | 39.39 V | 18.4% |
| AXITEC AC-370MH/144S | 370.0 W | 343.2 W | 47.4 V | 39.6 V | 18.65% |
How Many AXITEC AC-365MH/144S Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for AXITEC AC-365MH/144S (beta_Voc -0.275%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.05 V | 11 panels | 583.5 V | 18 panels |
| -10 C (14 F) | 51.75 V | 11 panels | 569.2 V | 19 panels |
| 0 C (32 F) | 50.46 V | 11 panels | 555.1 V | 19 panels |
| 25 C (77 F STC) | 47.21 V | 12 panels | 566.5 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-365MH/144S?
Closest cross-brand CEC competitors to AXITEC AC-365MH/144S matched near 365.0 W STC and 47.21 V Voc, led by Boviet Solar Technology Co Ltd BVM6612M-365-H.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6612M-365-H Boviet Solar Technology Co Ltd |
365.0 W | Tie (0 W) | 47.6 V | 18.81% | 93.0% |
| Boviet Solar Technology Co Ltd BVM6612M-W5-365-H Boviet Solar Technology Co Ltd |
365.0 W | Tie (0 W) | 47.6 V | 18.81% | 93.0% |
| CertainTeed CT365M10-02 CertainTeed |
365.0 W | Tie (0 W) | 47.66 V | 19.39% | 91.9% |
| CertainTeed CT365M11-02 CertainTeed |
365.0 W | Tie (0 W) | 47.66 V | 19.39% | 91.4% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-365MH/144S?
Evaluate AXITEC AC-365MH/144S (365.0 W STC, 47.21 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-365MH/144S reaches 53.05 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 470 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (470 sq ft).
- 2026 tax credit baseline: cash residential installs of AXITEC AC-365MH/144S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-365MH/144S 8 kW Residential Fit
Needs 22 modules (470 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-365-H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 338.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-365MH/144S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
How many AXITEC AC-365MH/144S panels fit on a 600 V winter solar string?
At -10 C (14 F), AXITEC AC-365MH/144S cold Voc rises from 47.21 V to 51.75 V (beta_Voc -0.275%/C), capping a 600 V string at 11 panels (569.2 V).
How much roof area does an 8 kW array of AXITEC AC-365MH/144S need?
An 8 kW DC system uses 22 AXITEC AC-365MH/144S modules (8,030 W STC / 7,445 W PTC), covering roughly 470 sq ft and saving ~$2,010/yr at 18.54 c/kWh.
How does AXITEC AC-365MH/144S compare against Boviet Solar Technology Co Ltd BVM6612M-365-H?
AXITEC AC-365MH/144S outputs 365.0 W STC (47.21 V Voc, rank #12,044 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-365-H delivers 365.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)