AXITEC AC-365MH/144S — CEC Solar Module Specifications

Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-365MH/144S is a 365.0 W STC (338.4 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 18.4% efficiency, 47.21 V Voc at 25 C, and 51.75 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
365.0 W
PTC Wattage
338.4 W
Voc @ 25C
47.21 V
Efficiency
18.4%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-365MH/144S Compare Against Peer CEC Listings?

Engineering position of AXITEC AC-365MH/144S (365.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612M-365-H across 5,889 CEC Mono-c-Si solar modules.

Ranking #12,044 across 21,677 CEC solar panels (below all-CEC median; higher than 42.9% of peers), AXITEC AC-365MH/144S operates as a compact residential or specialty off-grid module sitting 45.0 W below the 410.0 W Mono-c-Si median. Mid-range 47.21 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With strong 92.7% PTC-to-STC heat retention (#11,468 of 21,677), 22 panels occupy 470 sq ft and offset roughly $2,010/yr at average US rates (or $3,398/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does AXITEC AC-365MH/144S Fall Across Listed CEC Models?

Plots AXITEC AC-365MH/144S at 365.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-365MH/144S (365.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-365MH/14: 365.0 W

What Dataset Percentiles Define AXITEC AC-365MH/144S?

Benchmarks AXITEC AC-365MH/144S on STC wattage, thermal PTC/STC retention, and 18.4 aperture conversion efficiency against CEC peers.

AXITEC AC-365MH/144S Engineering BenchmarksPercentile comparison of AXITEC AC-365MH/144S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage365.0 WPTC/STC Retention92.7%Module Efficiency18.4%

What Do the Dataset Ranks Show for AXITEC AC-365MH/144S?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for AXITEC AC-365MH/144S by AXITEC.

Rank #12,044 / 21,677

365.0 W STC · Higher Than 42.9%

365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,501

18.4% Aperture Efficiency

Power density 184.0 W/m2 (1.51 percentage points below 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.75 V at -10 C (569.2 V string) and 53.05 V at -20 C (11 max).

8 kW Reference Array

22 Panels = 8,030 W STC

Occupies 43.6 m2 (470 sq ft) producing 7,445 W PTC; NEC 690.8 OCPD floor is 15.24 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.21 * (1 + (-0.275/100) * (-10 - 25)) = 51.75 V | OCPD = 1.56 * 9.77 = 15.24 A

Inputs from CEC Modules.csv for AXITEC AC-365MH/144S: Voc=47.21 V, beta_Voc=-0.275%/C, Isc=9.77 A, STC=365.0 W, Area=1.984 m2.

Result: 11 panels max on 600 V (569.2 V); 22 panels for 8 kW (470 sq ft).

What Are the Published CEC Specifications for AXITEC AC-365MH/144S?

Laboratory test ratings recorded for AXITEC AC-365MH/144S (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-365MH/144S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 365.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 338.4 W (92.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.21 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.77 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.39 V / 9.27 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.275 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.4% (1.984 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many AXITEC AC-365MH/144S Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (470 sq ft at 8 kW), and estimated Year-1 electric bill offset for AXITEC AC-365MH/144S.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.21 kW 363 sq ft $1,554 $2,628
8 kW Class 22 8.03 kW 470 sq ft $2,010 $3,398
10 kW Class 28 10.22 kW 598 sq ft $2,558 $4,325

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

Sibling wattage bins and frame colors grouped with AXITEC AC-365MH/144S under AXITEC to prevent duplicate spec pages.

Sibling CEC listings grouped into the AXITEC AC-365MH/144S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-355MH/144S 355.0 W 328.9 W 46.82 V 39.01 V 17.89%
AXITEC AC-360MH/144S 360.0 W 333.7 W 47.01 V 39.2 V 18.15%
AXITEC AC-365MH/144S 365.0 W 338.4 W 47.21 V 39.39 V 18.4%
AXITEC AC-370MH/144S 370.0 W 343.2 W 47.4 V 39.6 V 18.65%

How Many AXITEC AC-365MH/144S Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for AXITEC AC-365MH/144S (beta_Voc -0.275%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=47.21V and beta_Voc=-0.275%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.05 V 11 panels 583.5 V 18 panels
-10 C (14 F) 51.75 V 11 panels 569.2 V 19 panels
0 C (32 F) 50.46 V 11 panels 555.1 V 19 panels
25 C (77 F STC) 47.21 V 12 panels 566.5 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-365MH/144S?

Closest cross-brand CEC competitors to AXITEC AC-365MH/144S matched near 365.0 W STC and 47.21 V Voc, led by Boviet Solar Technology Co Ltd BVM6612M-365-H.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-365-H
Boviet Solar Technology Co Ltd
365.0 W Tie (0 W) 47.6 V 18.81% 93.0%
Boviet Solar Technology Co Ltd BVM6612M-W5-365-H
Boviet Solar Technology Co Ltd
365.0 W Tie (0 W) 47.6 V 18.81% 93.0%
CertainTeed CT365M10-02
CertainTeed
365.0 W Tie (0 W) 47.66 V 19.39% 91.9%
CertainTeed CT365M11-02
CertainTeed
365.0 W Tie (0 W) 47.66 V 19.39% 91.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-365MH/144S?

Evaluate AXITEC AC-365MH/144S (365.0 W STC, 47.21 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-365MH/144S reaches 53.05 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 470 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (470 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-365MH/144S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-365MH/144S 8 kW Residential Fit

Needs 22 modules (470 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-365-H.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 338.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-365MH/144S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

How many AXITEC AC-365MH/144S panels fit on a 600 V winter solar string?

At -10 C (14 F), AXITEC AC-365MH/144S cold Voc rises from 47.21 V to 51.75 V (beta_Voc -0.275%/C), capping a 600 V string at 11 panels (569.2 V).

How much roof area does an 8 kW array of AXITEC AC-365MH/144S need?

An 8 kW DC system uses 22 AXITEC AC-365MH/144S modules (8,030 W STC / 7,445 W PTC), covering roughly 470 sq ft and saving ~$2,010/yr at 18.54 c/kWh.

How does AXITEC AC-365MH/144S compare against Boviet Solar Technology Co Ltd BVM6612M-365-H?

AXITEC AC-365MH/144S outputs 365.0 W STC (47.21 V Voc, rank #12,044 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-365-H delivers 365.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.