AXITEC AC-365MH/144V is a 365.0 W STC (338.4 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 18.4% efficiency, 47.21 V Voc at 25 C, and 51.75 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 365.0 W
- PTC Wattage
- 338.4 W
- Voc @ 25C
- 47.21 V
- Efficiency
- 18.4%
How Does AXITEC AC-365MH/144V Compare Against Peer CEC Listings?
Solar engineering breakdown for AXITEC AC-365MH/144V: PTC thermal retention, roof footprint, and cold Voc string bounds. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Measured at 365.0 W STC and 338.4 W PTC, AXITEC AC-365MH/144V sits -20.0 W vs all-CEC median (below all-CEC median; higher than 42.9% of peers) among 21,677 listed modules. Power density reaches 184.0 W/m2 (1.51 percentage points below 19.91% CEC median). Mid-range 47.21 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer Boviet Solar Technology Co Ltd BVM6612M-365-H rates 365.0 W.
Where Does AXITEC AC-365MH/144V Fall Across Listed CEC Models?
Distribution marker showing AXITEC AC-365MH/144V (365.0 W) relative to the 385.0 W all-CEC solar panel median. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
What Dataset Percentiles Define AXITEC AC-365MH/144V?
Dataset percentiles tracking AXITEC AC-365MH/144V power output, thermal retention ratio, and aperture efficiency against 21,677 models. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
What Do the Dataset Ranks Show for AXITEC AC-365MH/144V?
Benchmark highlights for AXITEC AC-365MH/144V covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
365.0 W STC · Higher Than 42.9%
365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.4% Aperture Efficiency
Power density 184.0 W/m2 (1.51 percentage points below 19.91% CEC median). PTC/STC ratio: 92.7% (rank #11,468).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.75 V at -10 C (569.2 V string) and 53.05 V at -20 C (11 max).
22 Panels = 8,030 W STC
Occupies 43.6 m2 (470 sq ft) producing 7,445 W PTC; NEC 690.8 OCPD floor is 15.24 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.21 * (1 + (-0.275/100) * (-10 - 25)) = 51.75 V | OCPD = 1.56 * 9.77 = 15.24 A
Inputs from CEC Modules.csv for AXITEC AC-365MH/144V: Voc=47.21 V, beta_Voc=-0.275%/C, Isc=9.77 A, STC=365.0 W, Area=1.984 m2.
Result: 11 panels max on 600 V (569.2 V); 22 panels for 8 kW (470 sq ft).
What Are the Published CEC Specifications for AXITEC AC-365MH/144V?
Official CEC datasheet figures for AXITEC AC-365MH/144V (Mono-c-Si) used in utility interconnection and permit reviews. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 365.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 338.4 W (92.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.21 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.77 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.39 V / 9.27 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.275 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.4% (1.984 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-365MH/144V Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many AXITEC AC-365MH/144V modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.21 kW | 363 sq ft | $1,554 | $2,628 |
| 8 kW Class | 22 | 8.03 kW | 470 sq ft | $2,010 | $3,398 |
| 10 kW Class | 28 | 10.22 kW | 598 sq ft | $2,558 | $4,325 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
Consolidated AXITEC wattage variants sharing the AXITEC AC-365MH/144V mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-355MH/144V | 355.0 W | 328.9 W | 46.82 V | 39.01 V | 17.89% |
| AXITEC AC-360MH/144V | 360.0 W | 333.7 W | 47.01 V | 39.2 V | 18.15% |
| AXITEC AC-365MH/144V | 365.0 W | 338.4 W | 47.21 V | 39.39 V | 18.4% |
| AXITEC AC-370MH/144V | 370.0 W | 343.2 W | 47.4 V | 39.6 V | 18.65% |
How Many AXITEC AC-365MH/144V Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on AXITEC AC-365MH/144V (51.75 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.05 V | 11 panels | 583.5 V | 18 panels |
| -10 C (14 F) | 51.75 V | 11 panels | 569.2 V | 19 panels |
| 0 C (32 F) | 50.46 V | 11 panels | 555.1 V | 19 panels |
| 25 C (77 F STC) | 47.21 V | 12 panels | 566.5 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-365MH/144V?
Competing CEC solar panels closest to AXITEC AC-365MH/144V in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6612M-365-H.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6612M-365-H Boviet Solar Technology Co Ltd |
365.0 W | Tie (0 W) | 47.6 V | 18.81% | 93.0% |
| Boviet Solar Technology Co Ltd BVM6612M-W5-365-H Boviet Solar Technology Co Ltd |
365.0 W | Tie (0 W) | 47.6 V | 18.81% | 93.0% |
| CertainTeed CT365M10-02 CertainTeed |
365.0 W | Tie (0 W) | 47.66 V | 19.39% | 91.9% |
| CertainTeed CT365M11-02 CertainTeed |
365.0 W | Tie (0 W) | 47.66 V | 19.39% | 91.4% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-365MH/144V?
Evaluate AXITEC AC-365MH/144V (365.0 W STC, 47.21 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-365MH/144V reaches 53.05 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 470 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (470 sq ft).
- 2026 tax credit baseline: cash residential installs of AXITEC AC-365MH/144V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-365MH/144V 8 kW Residential Fit
Needs 22 modules (470 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-365-H.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 338.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-365MH/144V by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
How many AXITEC AC-365MH/144V panels fit on a 600 V winter solar string?
At -10 C (14 F), AXITEC AC-365MH/144V cold Voc rises from 47.21 V to 51.75 V (beta_Voc -0.275%/C), capping a 600 V string at 11 panels (569.2 V).
How much roof area does an 8 kW array of AXITEC AC-365MH/144V need?
An 8 kW DC system uses 22 AXITEC AC-365MH/144V modules (8,030 W STC / 7,445 W PTC), covering roughly 470 sq ft and saving ~$2,010/yr at 18.54 c/kWh.
How does AXITEC AC-365MH/144V compare against Boviet Solar Technology Co Ltd BVM6612M-365-H?
AXITEC AC-365MH/144V outputs 365.0 W STC (47.21 V Voc, rank #12,044 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-365-H delivers 365.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)