Trina Solar TSM-335PE14A — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-335PE14A is a 335.0 W STC (307.4 W PTC) Multi-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 17.45% efficiency, 46.0 V Voc at 25 C, and 50.56 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
335.0 W
PTC Wattage
307.4 W
Voc @ 25C
46.0 V
Efficiency
17.45%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-335PE14A Compare Against Peer CEC Listings?

Engineering position of Trina Solar TSM-335PE14A (335.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612P-335 across 1,407 CEC Multi-c-Si solar modules.

Ranking #13,844 across 21,677 CEC solar panels (below all-CEC median; higher than 34.7% of peers), Trina Solar TSM-335PE14A operates as a compact residential or specialty off-grid module sitting 56.2 W above the 278.8 W Multi-c-Si median. Mid-range 46.0 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With strong 91.8% PTC-to-STC heat retention (#14,745 of 21,677), 24 panels occupy 496 sq ft and offset roughly $2,012/yr at average US rates (or $3,403/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Trina Solar TSM-335PE14A Fall Across Listed CEC Models?

Plots Trina Solar TSM-335PE14A at 335.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-335PE14A (335.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-33: 335.0 W

What Dataset Percentiles Define Trina Solar TSM-335PE14A?

Benchmarks Trina Solar TSM-335PE14A on STC wattage, thermal PTC/STC retention, and 17.45 aperture conversion efficiency against CEC peers.

Trina Solar TSM-335PE14A Engineering BenchmarksPercentile comparison of Trina Solar TSM-335PE14A wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage335.0 WPTC/STC Retention91.8%Module Efficiency17.45%

What Do the Dataset Ranks Show for Trina Solar TSM-335PE14A?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Trina Solar TSM-335PE14A by Trina Solar.

Rank #13,844 / 21,677

335.0 W STC · Higher Than 34.7%

335.0 W STC (-50.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #15,846

17.45% Aperture Efficiency

Power density 174.5 W/m2 (2.46 percentage points below 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.56 V at -10 C (556.2 V string) and 51.86 V at -20 C (11 max).

8 kW Reference Array

24 Panels = 8,040 W STC

Occupies 46.1 m2 (496 sq ft) producing 7,378 W PTC; NEC 690.8 OCPD floor is 14.59 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.0 * (1 + (-0.283/100) * (-10 - 25)) = 50.56 V | OCPD = 1.56 * 9.35 = 14.59 A

Inputs from CEC Modules.csv for Trina Solar TSM-335PE14A: Voc=46.0 V, beta_Voc=-0.283%/C, Isc=9.35 A, STC=335.0 W, Area=1.92 m2.

Result: 11 panels max on 600 V (556.2 V); 24 panels for 8 kW (496 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-335PE14A?

Laboratory test ratings recorded for Trina Solar TSM-335PE14A (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-335PE14A.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 335.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 307.4 W (91.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.35 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.6 V / 8.91 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.283 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.45% (1.92 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Trina Solar TSM-335PE14A Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (496 sq ft at 8 kW), and estimated Year-1 electric bill offset for Trina Solar TSM-335PE14A.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.03 kW 372 sq ft $1,509 $2,552
8 kW Class 24 8.04 kW 496 sq ft $2,012 $3,403
10 kW Class 30 10.05 kW 620 sq ft $2,515 $4,253

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Sibling wattage bins and frame colors grouped with Trina Solar TSM-335PE14A under Trina Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the Trina Solar TSM-335PE14A wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-325PE14A 325.0 W 296.7 W 46.1 V 37.6 V 16.75%
Trina Solar TSM-330PE14A 330.0 W 301.4 W 46.5 V 37.8 V 17.01%
Trina Solar TSM-335PE14A 335.0 W 307.4 W 46.0 V 37.6 V 17.45%
Trina Solar TSM-340PE14A 340.0 W 312.1 W 46.4 V 37.8 V 17.71%

How Many Trina Solar TSM-335PE14A Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Trina Solar TSM-335PE14A (beta_Voc -0.283%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=46.0V and beta_Voc=-0.283%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.86 V 11 panels 570.5 V 19 panels
-10 C (14 F) 50.56 V 11 panels 556.2 V 19 panels
0 C (32 F) 49.25 V 12 panels 591.0 V 20 panels
25 C (77 F STC) 46.0 V 13 panels 598.0 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-335PE14A?

Closest cross-brand CEC competitors to Trina Solar TSM-335PE14A matched near 335.0 W STC and 46.0 V Voc, led by Boviet Solar Technology Co Ltd BVM6612P-335.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612P-335
Boviet Solar Technology Co Ltd
335.0 W Tie (0 W) 46.1 V 17.27% 92.5%
AXITEC AC-335P/156-72S
AXITEC
335.0 W Tie (0 W) 46.2 V 17.26% 91.0%
CSI Solar Co Ltd CS6U-335P
CSI Solar Co Ltd
335.0 W Tie (0 W) 45.8 V 19.25% 92.4%
Flextronics FXS-335BB-SAD1W
Flextronics
335.0 W Tie (0 W) 46.2 V 17.13% 91.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-335PE14A?

Evaluate Trina Solar TSM-335PE14A (335.0 W STC, 46.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-335PE14A reaches 51.86 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 496 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (496 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-335PE14A carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-335PE14A 8 kW Residential Fit

Needs 24 modules (496 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612P-335.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 307.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-335PE14A by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Trina Solar TSM-335PE14A panels fit on a 600 V winter solar string?

At -10 C (14 F), Trina Solar TSM-335PE14A cold Voc rises from 46.0 V to 50.56 V (beta_Voc -0.283%/C), capping a 600 V string at 11 panels (556.2 V).

How much roof area does an 8 kW array of Trina Solar TSM-335PE14A need?

An 8 kW DC system uses 24 Trina Solar TSM-335PE14A modules (8,040 W STC / 7,378 W PTC), covering roughly 496 sq ft and saving ~$2,012/yr at 18.54 c/kWh.

How does Trina Solar TSM-335PE14A compare against Boviet Solar Technology Co Ltd BVM6612P-335?

Trina Solar TSM-335PE14A outputs 335.0 W STC (46.0 V Voc, rank #13,844 of 21,677), while Boviet Solar Technology Co Ltd BVM6612P-335 delivers 335.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.