CSI Solar Co Ltd CS6U-335P is a 335.0 W STC (309.6 W PTC) Multi-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 19.25% efficiency, 45.8 V Voc at 25 C, and 50.8 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 335.0 W
- PTC Wattage
- 309.6 W
- Voc @ 25C
- 45.8 V
- Efficiency
- 19.25%
How Does CSI Solar Co Ltd CS6U-335P Compare Against Peer CEC Listings?
Solar engineering breakdown for CSI Solar Co Ltd CS6U-335P: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 335.0 W STC and 309.6 W PTC, CSI Solar Co Ltd CS6U-335P sits -50.0 W vs all-CEC median (below all-CEC median; higher than 34.7% of peers) among 21,677 listed modules. Power density reaches 192.5 W/m2 (0.66 percentage points below 19.91% CEC median). Mid-range 45.8 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer Boviet Solar Technology Co Ltd BVM6612P-335 rates 335.0 W.
Where Does CSI Solar Co Ltd CS6U-335P Fall Across Listed CEC Models?
Distribution marker showing CSI Solar Co Ltd CS6U-335P (335.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define CSI Solar Co Ltd CS6U-335P?
Dataset percentiles tracking CSI Solar Co Ltd CS6U-335P power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS6U-335P?
Benchmark highlights for CSI Solar Co Ltd CS6U-335P covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
335.0 W STC · Higher Than 34.7%
335.0 W STC (-50.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
19.25% Aperture Efficiency
Power density 192.5 W/m2 (0.66 percentage points below 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.8 V at -10 C (558.8 V string) and 52.23 V at -20 C (11 max).
24 Panels = 8,040 W STC
Occupies 41.8 m2 (450 sq ft) producing 7,430 W PTC; NEC 690.8 OCPD floor is 14.88 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.8 * (1 + (-0.312/100) * (-10 - 25)) = 50.8 V | OCPD = 1.56 * 9.54 = 14.88 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS6U-335P: Voc=45.8 V, beta_Voc=-0.312%/C, Isc=9.54 A, STC=335.0 W, Area=1.74 m2.
Result: 11 panels max on 600 V (558.8 V); 24 panels for 8 kW (450 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS6U-335P?
Official CEC datasheet figures for CSI Solar Co Ltd CS6U-335P (Multi-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 335.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 309.6 W (92.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.54 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.4 V / 8.96 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.312 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.25% (1.74 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many CSI Solar Co Ltd CS6U-335P Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many CSI Solar Co Ltd CS6U-335P modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.03 kW | 337 sq ft | $1,509 | $2,552 |
| 8 kW Class | 24 | 8.04 kW | 450 sq ft | $2,012 | $3,403 |
| 10 kW Class | 30 | 10.05 kW | 562 sq ft | $2,515 | $4,253 |
Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?
Consolidated CSI Solar Co Ltd wattage variants sharing the CSI Solar Co Ltd CS6U-335P mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS6U-325P | 325.0 W | 300.1 W | 45.5 V | 37.0 V | 18.68% |
| CSI Solar Co Ltd CS6U-330P | 330.0 W | 304.9 W | 45.6 V | 37.2 V | 18.97% |
| CSI Solar Co Ltd CS6U-335P | 335.0 W | 309.6 W | 45.8 V | 37.4 V | 19.25% |
| CSI Solar Co Ltd CS6U-340P | 340.0 W | 314.4 W | 45.9 V | 37.6 V | 19.54% |
How Many CSI Solar Co Ltd CS6U-335P Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on CSI Solar Co Ltd CS6U-335P (50.8 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.23 V | 11 panels | 574.5 V | 19 panels |
| -10 C (14 F) | 50.8 V | 11 panels | 558.8 V | 19 panels |
| 0 C (32 F) | 49.37 V | 12 panels | 592.4 V | 20 panels |
| 25 C (77 F STC) | 45.8 V | 13 panels | 595.4 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS6U-335P?
Competing CEC solar panels closest to CSI Solar Co Ltd CS6U-335P in nameplate wattage and Voc, starting with Boviet Solar Technology Co Ltd BVM6612P-335.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Boviet Solar Technology Co Ltd BVM6612P-335 Boviet Solar Technology Co Ltd |
335.0 W | Tie (0 W) | 46.1 V | 17.27% | 92.5% |
| AXITEC AC-335P/156-72S AXITEC |
335.0 W | Tie (0 W) | 46.2 V | 17.26% | 91.0% |
| Flextronics FXS-335BB-SAD1W Flextronics |
335.0 W | Tie (0 W) | 46.2 V | 17.13% | 91.2% |
| Boviet Solar Technology Co Ltd BVM6612M-335 Boviet Solar Technology Co Ltd |
335.0 W | Tie (0 W) | 46.4 V | 17.27% | 91.7% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS6U-335P?
Evaluate CSI Solar Co Ltd CS6U-335P (335.0 W STC, 45.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS6U-335P reaches 52.23 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 450 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (450 sq ft).
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS6U-335P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS6U-335P 8 kW Residential Fit
Needs 24 modules (450 sq ft) with a 15 A string OCPD, offsetting ~$2,012/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612P-335.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 309.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS6U-335P by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many CSI Solar Co Ltd CS6U-335P panels fit on a 600 V winter solar string?
At -10 C (14 F), CSI Solar Co Ltd CS6U-335P cold Voc rises from 45.8 V to 50.8 V (beta_Voc -0.312%/C), capping a 600 V string at 11 panels (558.8 V).
How much roof area does an 8 kW array of CSI Solar Co Ltd CS6U-335P need?
An 8 kW DC system uses 24 CSI Solar Co Ltd CS6U-335P modules (8,040 W STC / 7,430 W PTC), covering roughly 450 sq ft and saving ~$2,012/yr at 18.54 c/kWh.
How does CSI Solar Co Ltd CS6U-335P compare against Boviet Solar Technology Co Ltd BVM6612P-335?
CSI Solar Co Ltd CS6U-335P outputs 335.0 W STC (45.8 V Voc, rank #13,844 of 21,677), while Boviet Solar Technology Co Ltd BVM6612P-335 delivers 335.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)