Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-330PEG1440 — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-330PEG1440 is a 330.0 W STC (299.7 W PTC) Multi-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 16.82% efficiency, 46.2 V Voc at 25 C, and 51.07 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
330.0 W
PTC Wattage
299.7 W
Voc @ 25C
46.2 V
Efficiency
16.82%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-330PEG1440 Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-330PEG1440 handles rooftop heat (299.7 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Trina Solar TSM-330PEG1440 exhibits 9.23 A short-circuit current, requiring a 14.4 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #14,165 of 21,677 (51.2 W above the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 49.0 m2 for an 8 kW system (31 panels for 10 kW). Mid-range 46.2 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does Trina Solar TSM-330PEG1440 Fall Across Listed CEC Models?

Where Trina Solar TSM-330PEG1440 (330.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-330PEG1440 (330.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-33: 330.0 W

What Dataset Percentiles Define Trina Solar TSM-330PEG1440?

Percentile placement of Trina Solar TSM-330PEG1440 across power density (168.2 W/m2), thermal retention, and nameplate STC wattage.

Trina Solar TSM-330PEG1440 Engineering BenchmarksPercentile comparison of Trina Solar TSM-330PEG1440 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage330.0 WPTC/STC Retention90.8%Module Efficiency16.82%

What Do the Dataset Ranks Show for Trina Solar TSM-330PEG1440?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-330PEG1440 specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #14,165 / 21,677

330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,751

16.82% Aperture Efficiency

Power density 168.2 W/m2 (3.09 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.07 V at -10 C (561.8 V string) and 52.46 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,250 W STC

Occupies 49.0 m2 (528 sq ft) producing 7,492 W PTC; NEC 690.8 OCPD floor is 14.4 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.2 * (1 + (-0.301/100) * (-10 - 25)) = 51.07 V | OCPD = 1.56 * 9.23 = 14.4 A

Inputs from CEC Modules.csv for Trina Solar TSM-330PEG1440: Voc=46.2 V, beta_Voc=-0.301%/C, Isc=9.23 A, STC=330.0 W, Area=1.962 m2.

Result: 11 panels max on 600 V (561.8 V); 25 panels for 8 kW (528 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-330PEG1440?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-330PEG1440.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-330PEG1440.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 330.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 299.7 W (90.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.23 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.6 V / 8.78 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.301 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.82% (1.962 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Trina Solar TSM-330PEG1440 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-330PEG1440 (330.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.27 kW 401 sq ft $1,569 $2,654
8 kW Class 25 8.25 kW 528 sq ft $2,065 $3,492
10 kW Class 31 10.23 kW 655 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-330PEG1440 architecture. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the Trina Solar TSM-330PEG1440 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-325PEG1440 325.0 W 295.0 W 46.1 V 37.4 V 16.56%
Trina Solar TSM-330PEG1440 330.0 W 299.7 W 46.2 V 37.6 V 16.82%
Trina Solar TSM-335PEG1440 335.0 W 307.3 W 46.0 V 37.8 V 17.07%

How Many Trina Solar TSM-330PEG1440 Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-330PEG1440 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=46.2V and beta_Voc=-0.301%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.46 V 11 panels 577.1 V 19 panels
-10 C (14 F) 51.07 V 11 panels 561.8 V 19 panels
0 C (32 F) 49.68 V 12 panels 596.2 V 20 panels
25 C (77 F STC) 46.2 V 12 panels 554.4 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-330PEG1440?

Alternative CEC solar modules from competing brands near Trina Solar TSM-330PEG1440 (330.0 W), including GCL System Integration Technology Co Ltd GCL-M6/72330.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-M6/72330
GCL System Integration Technology Co Ltd
330.0 W Tie (0 W) 46.2 V 17.01% 90.4%
GCL System Integration Technology Co Ltd GCL-P6/72330
GCL System Integration Technology Co Ltd
330.0 W Tie (0 W) 46.2 V 17.01% 90.7%
Centrosolar America TM7 330SW
Centrosolar America
330.0 W Tie (0 W) 46.1 V 16.92% 91.0%
Centrosolar America TM7S 330SW
Centrosolar America
330.0 W Tie (0 W) 46.1 V 16.92% 91.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-330PEG1440?

Evaluate Trina Solar TSM-330PEG1440 (330.0 W STC, 46.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-330PEG1440 reaches 52.46 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 528 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (528 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-330PEG1440 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-330PEG1440 8 kW Residential Fit

Needs 25 modules (528 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/72330.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 299.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-330PEG1440 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Trina Solar TSM-330PEG1440 PTC wattage (299.7 W) lower than STC (330.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 299.7 W PTC (90.8% retention) across Trina Solar TSM-330PEG1440's 1.962 m2 aperture.

Who should skip Trina Solar TSM-330PEG1440 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 25 Trina Solar TSM-330PEG1440 panels (528 sq ft) leave unusable roof gaps vs. GCL System Integration Technology Co Ltd GCL-M6/72330.

What is the 1,000 V commercial string limit for Trina Solar TSM-330PEG1440?

On 1,000 V commercial inverters at -10 C (51.07 V cold Voc), Trina Solar TSM-330PEG1440 fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-330PEG1440.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.