Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-330PEG14 — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-330PEG14 is a 330.0 W STC (302.6 W PTC) Multi-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 16.82% efficiency, 45.8 V Voc at 25 C, and 50.93 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
330.0 W
PTC Wattage
302.6 W
Voc @ 25C
45.8 V
Efficiency
16.82%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-330PEG14 Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-330PEG14 handles rooftop heat (302.6 W PTC), 8 kW sizing, and cold winter string voltage.

Trina Solar builds the Trina Solar TSM-330PEG14 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 168.2 W/m2 (3.09 percentage points below 19.91% CEC median). Compared against Centrosolar America DP72 330 (330.0 W), this model holds strong 91.7% PTC-to-STC heat retention (#15,053 of 21,677). Mid-range 45.8 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 14.52 A overcurrent floor served by a 15 A breaker.

Where Does Trina Solar TSM-330PEG14 Fall Across Listed CEC Models?

Where Trina Solar TSM-330PEG14 (330.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-330PEG14 (330.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-33: 330.0 W

What Dataset Percentiles Define Trina Solar TSM-330PEG14?

Percentile placement of Trina Solar TSM-330PEG14 across power density (168.2 W/m2), thermal retention, and nameplate STC wattage.

Trina Solar TSM-330PEG14 Engineering BenchmarksPercentile comparison of Trina Solar TSM-330PEG14 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage330.0 WPTC/STC Retention91.7%Module Efficiency16.82%

What Do the Dataset Ranks Show for Trina Solar TSM-330PEG14?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-330PEG14 specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #14,165 / 21,677

330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,751

16.82% Aperture Efficiency

Power density 168.2 W/m2 (3.09 percentage points below 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.93 V at -10 C (560.2 V string) and 52.4 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,250 W STC

Occupies 49.0 m2 (528 sq ft) producing 7,565 W PTC; NEC 690.8 OCPD floor is 14.52 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.8 * (1 + (-0.32/100) * (-10 - 25)) = 50.93 V | OCPD = 1.56 * 9.31 = 14.52 A

Inputs from CEC Modules.csv for Trina Solar TSM-330PEG14: Voc=45.8 V, beta_Voc=-0.32%/C, Isc=9.31 A, STC=330.0 W, Area=1.962 m2.

Result: 11 panels max on 600 V (560.2 V); 25 panels for 8 kW (528 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-330PEG14?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-330PEG14.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-330PEG14.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 330.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 302.6 W (91.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.31 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.6 V / 8.78 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.32 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.82% (1.962 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Trina Solar TSM-330PEG14 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-330PEG14 (330.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.27 kW 401 sq ft $1,569 $2,654
8 kW Class 25 8.25 kW 528 sq ft $2,065 $3,492
10 kW Class 31 10.23 kW 655 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-330PEG14 architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Trina Solar TSM-330PEG14 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-325PEG14 325.0 W 295.0 W 46.1 V 37.4 V 16.56%
Trina Solar TSM-330PEG14 330.0 W 302.6 W 45.8 V 37.6 V 16.82%
Trina Solar TSM-335PEG14 335.0 W 307.3 W 46.0 V 37.8 V 17.07%

How Many Trina Solar TSM-330PEG14 Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-330PEG14 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.8V and beta_Voc=-0.32%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.4 V 11 panels 576.4 V 19 panels
-10 C (14 F) 50.93 V 11 panels 560.2 V 19 panels
0 C (32 F) 49.46 V 12 panels 593.5 V 20 panels
25 C (77 F STC) 45.8 V 13 panels 595.4 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-330PEG14?

Alternative CEC solar modules from competing brands near Trina Solar TSM-330PEG14 (330.0 W), including Centrosolar America DP72 330.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America DP72 330
Centrosolar America
330.0 W Tie (0 W) 45.8 V 16.97% 90.4%
AXITEC AC-330P/72S
AXITEC
330.0 W Tie (0 W) 45.97 V 17.1% 92.3%
AXITEC AC-330P/72V
AXITEC
330.0 W Tie (0 W) 45.97 V 17.1% 92.3%
CSI Solar Co Ltd CS6X-330P
CSI Solar Co Ltd
330.0 W Tie (0 W) 45.6 V 17.36% 91.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-330PEG14?

Evaluate Trina Solar TSM-330PEG14 (330.0 W STC, 45.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-330PEG14 reaches 52.4 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 528 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (528 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-330PEG14 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-330PEG14 8 kW Residential Fit

Needs 25 modules (528 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America DP72 330.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 302.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-330PEG14 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-330PEG14?

Multiplying Trina Solar TSM-330PEG14's 9.31 A short-circuit current by 1.56 equals 14.52 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Trina Solar TSM-330PEG14 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.93 V cold Voc at 14 F and handles 9.31 A Isc; string inverters cap Trina Solar TSM-330PEG14 at 11 panels on 600 V.

Is Trina Solar TSM-330PEG14 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-330PEG14 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.