Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-330PD1418 — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-330PD1418 is a 330.0 W STC (301.4 W PTC) Multi-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 17.01% efficiency, 46.5 V Voc at 25 C, and 51.56 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
330.0 W
PTC Wattage
301.4 W
Voc @ 25C
46.5 V
Efficiency
17.01%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-330PD1418 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Trina Solar TSM-330PD1418 (Multi-c-Si) residential solar systems.

Homeowners evaluating Trina Solar TSM-330PD1418 need 19 panels for 6 kW or 25 panels (522 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft). Under NEC 690.7(A), beta_Voc (-0.311%/C) pushes open-circuit voltage to 51.56 V at 14 F and 53.01 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Trina Solar TSM-330PD1418 Fall Across Listed CEC Models?

Comparison of Trina Solar TSM-330PD1418 (330.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-330PD1418 (330.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-33: 330.0 W

What Dataset Percentiles Define Trina Solar TSM-330PD1418?

Relative ranking of Trina Solar TSM-330PD1418 across nameplate watts, 91.3% PTC thermal ratio, and module aperture efficiency. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Trina Solar TSM-330PD1418 Engineering BenchmarksPercentile comparison of Trina Solar TSM-330PD1418 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage330.0 WPTC/STC Retention91.3%Module Efficiency17.01%

What Do the Dataset Ranks Show for Trina Solar TSM-330PD1418?

Summary of Trina Solar TSM-330PD1418 output rank, 8 kW array size (25 panels), efficiency rating, and 600 V string limit.

Rank #14,165 / 21,677

330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,431

17.01% Aperture Efficiency

Power density 170.1 W/m2 (2.90 percentage points below 19.91% CEC median). PTC/STC ratio: 91.3% (rank #16,023).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.56 V at -10 C (567.2 V string) and 53.01 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,250 W STC

Occupies 48.5 m2 (522 sq ft) producing 7,535 W PTC; NEC 690.8 OCPD floor is 14.37 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.5 * (1 + (-0.311/100) * (-10 - 25)) = 51.56 V | OCPD = 1.56 * 9.21 = 14.37 A

Inputs from CEC Modules.csv for Trina Solar TSM-330PD1418: Voc=46.5 V, beta_Voc=-0.311%/C, Isc=9.21 A, STC=330.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (567.2 V); 25 panels for 8 kW (522 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-330PD1418?

Complete CEC test sheet for Trina Solar TSM-330PD1418 including Isc (9.21 A), Voc (46.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-330PD1418.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 330.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 301.4 W (91.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.21 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.8 V / 8.73 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.311 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.01% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Trina Solar TSM-330PD1418 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Trina Solar TSM-330PD1418.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.27 kW 397 sq ft $1,569 $2,654
8 kW Class 25 8.25 kW 522 sq ft $2,065 $3,492
10 kW Class 31 10.23 kW 647 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Related Trina Solar power steps and black/silver trims consolidated into this Trina Solar TSM-330PD1418 series guide. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the Trina Solar TSM-330PD1418 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-325PD1418 325.0 W 296.7 W 46.1 V 37.6 V 16.75%
Trina Solar TSM-330PD1418 330.0 W 301.4 W 46.5 V 37.8 V 17.01%

How Many Trina Solar TSM-330PD1418 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Trina Solar TSM-330PD1418 (46.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=46.5V and beta_Voc=-0.311%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.01 V 11 panels 583.1 V 18 panels
-10 C (14 F) 51.56 V 11 panels 567.2 V 19 panels
0 C (32 F) 50.12 V 11 panels 551.3 V 19 panels
25 C (77 F STC) 46.5 V 12 panels 558.0 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-330PD1418?

Four comparable CEC modules such as Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W (330.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
330.0 W Tie (0 W) 46.65 V 17.16% 91.3%
Centrosolar America EP72 330BW
Centrosolar America
330.0 W Tie (0 W) 46.65 V 17.16% 91.3%
Centrosolar America EP72 330SW
Centrosolar America
330.0 W Tie (0 W) 46.65 V 17.16% 91.3%
GCL System Integration Technology Co Ltd GCL-M6/72330
GCL System Integration Technology Co Ltd
330.0 W Tie (0 W) 46.2 V 17.01% 90.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-330PD1418?

Evaluate Trina Solar TSM-330PD1418 (330.0 W STC, 46.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-330PD1418 reaches 53.01 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-330PD1418 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-330PD1418 8 kW Residential Fit

Needs 25 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 301.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-330PD1418 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Trina Solar TSM-330PD1418 PTC wattage (301.4 W) lower than STC (330.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 301.4 W PTC (91.3% retention) across Trina Solar TSM-330PD1418's 1.94 m2 aperture.

Who should skip Trina Solar TSM-330PD1418 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 25 Trina Solar TSM-330PD1418 panels (522 sq ft) leave unusable roof gaps vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W.

What is the 1,000 V commercial string limit for Trina Solar TSM-330PD1418?

On 1,000 V commercial inverters at -10 C (51.56 V cold Voc), Trina Solar TSM-330PD1418 fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-330PD1418.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.