Trina Solar TSM-310PD1410 is a 310.0 W STC (280.8 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 16.14% efficiency, 45.3 V Voc at 25 C, and 50.36 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
310.0 W
PTC Wattage
280.8 W
Voc @ 25C
45.3 V
Efficiency
16.14%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-310PD1410 Compare Against Peer CEC Listings?

Engineering position of Trina Solar TSM-310PD1410 (310.0 W STC) vs. Advance Power API-P310 across 1,407 CEC Multi-c-Si solar modules.

Ranking #15,760 across 21,677 CEC solar panels (below all-CEC median; higher than 25.6% of peers), Trina Solar TSM-310PD1410 operates as a compact residential or specialty off-grid module sitting 31.2 W above the 278.8 W Multi-c-Si median. Mid-range 45.3 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With typical 90.6% PTC-to-STC thermal output (280.8 W real-world rating), 26 panels occupy 538 sq ft and offset roughly $2,017/yr at average US rates (or $3,411/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Trina Solar TSM-310PD1410 Fall Across Listed CEC Models?

Plots Trina Solar TSM-310PD1410 at 310.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-310PD1410 (310.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-31: 310.0 W

What Dataset Percentiles Define Trina Solar TSM-310PD1410?

Benchmarks Trina Solar TSM-310PD1410 on STC wattage, thermal PTC/STC retention, and 16.14 aperture conversion efficiency against CEC peers.

Trina Solar TSM-310PD1410 Engineering BenchmarksPercentile comparison of Trina Solar TSM-310PD1410 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage310.0 WPTC/STC Retention90.6%Module Efficiency16.14%

What Do the Dataset Ranks Show for Trina Solar TSM-310PD1410?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Trina Solar TSM-310PD1410 by Trina Solar.

Rank #15,760 / 21,677

310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #17,936

16.14% Aperture Efficiency

Power density 161.4 W/m2 (3.77 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.36 V at -10 C (554.0 V string) and 51.8 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,060 W STC

Occupies 49.9 m2 (538 sq ft) producing 7,301 W PTC; NEC 690.8 OCPD floor is 13.95 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.3 * (1 + (-0.319/100) * (-10 - 25)) = 50.36 V | OCPD = 1.56 * 8.94 = 13.95 A

Inputs from CEC Modules.csv for Trina Solar TSM-310PD1410: Voc=45.3 V, beta_Voc=-0.319%/C, Isc=8.94 A, STC=310.0 W, Area=1.921 m2.

Result: 11 panels max on 600 V (554.0 V); 26 panels for 8 kW (538 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-310PD1410?

Laboratory test ratings recorded for Trina Solar TSM-310PD1410 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-310PD1410.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 310.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 280.8 W (90.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.3 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.94 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.8 V / 8.42 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.319 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.14% (1.921 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Trina Solar TSM-310PD1410 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (538 sq ft at 8 kW), and estimated Year-1 electric bill offset for Trina Solar TSM-310PD1410.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.2 kW 414 sq ft $1,552 $2,624
8 kW Class 26 8.06 kW 538 sq ft $2,017 $3,411
10 kW Class 33 10.23 kW 682 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Sibling wattage bins and frame colors grouped with Trina Solar TSM-310PD1410 under Trina Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the Trina Solar TSM-310PD1410 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-300PD1410 300.0 W 271.5 W 45.1 V 36.6 V 15.62%
Trina Solar TSM-305PD1410 305.0 W 276.2 W 45.2 V 36.7 V 15.88%
Trina Solar TSM-310PD1410 310.0 W 280.8 W 45.3 V 36.8 V 16.14%
Trina Solar TSM-315PD1410 315.0 W 289.5 W 45.6 V 37.05 V 16.4%
Trina Solar TSM-320PD1410 320.0 W 292.0 W 45.8 V 37.1 V 16.49%

How Many Trina Solar TSM-310PD1410 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Trina Solar TSM-310PD1410 (beta_Voc -0.319%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=45.3V and beta_Voc=-0.319%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.8 V 11 panels 569.8 V 19 panels
-10 C (14 F) 50.36 V 11 panels 554.0 V 19 panels
0 C (32 F) 48.91 V 12 panels 586.9 V 20 panels
25 C (77 F STC) 45.3 V 13 panels 588.9 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-310PD1410?

Closest cross-brand CEC competitors to Trina Solar TSM-310PD1410 matched near 310.0 W STC and 45.3 V Voc, led by Advance Power API-P310.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Advance Power API-P310
Advance Power
310.0 W Tie (0 W) 45.22 V 15.89% 89.5%
Auxin Solar AXN6P612T310
Auxin Solar
310.0 W Tie (0 W) 45.22 V 15.89% 89.5%
Chinaland Solar Energy HSE310-72M
Chinaland Solar Energy
310.0 W Tie (0 W) 45.4 V 16.06% 90.3%
GCL System Integration Technology Co Ltd GCL-P6/72310
GCL System Integration Technology Co Ltd
310.0 W Tie (0 W) 45.4 V 15.98% 90.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-310PD1410?

Evaluate Trina Solar TSM-310PD1410 (310.0 W STC, 45.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-310PD1410 reaches 51.8 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 538 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (538 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-310PD1410 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-310PD1410 8 kW Residential Fit

Needs 26 modules (538 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-P310.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 280.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-310PD1410 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Trina Solar TSM-310PD1410 panels fit on a 600 V winter solar string?

At -10 C (14 F), Trina Solar TSM-310PD1410 cold Voc rises from 45.3 V to 50.36 V (beta_Voc -0.319%/C), capping a 600 V string at 11 panels (554.0 V).

How much roof area does an 8 kW array of Trina Solar TSM-310PD1410 need?

An 8 kW DC system uses 26 Trina Solar TSM-310PD1410 modules (8,060 W STC / 7,301 W PTC), covering roughly 538 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

How does Trina Solar TSM-310PD1410 compare against Advance Power API-P310?

Trina Solar TSM-310PD1410 outputs 310.0 W STC (45.3 V Voc, rank #15,760 of 21,677), while Advance Power API-P310 delivers 310.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.