Trina Solar TSM-310PD1408 is a 310.0 W STC (280.8 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 16.14% efficiency, 45.3 V Voc at 25 C, and 50.36 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 280.8 W
- Voc @ 25C
- 45.3 V
- Efficiency
- 16.14%
How Does Trina Solar TSM-310PD1408 Compare Against Peer CEC Listings?
Solar engineering breakdown for Trina Solar TSM-310PD1408: PTC thermal retention, roof footprint, and cold Voc string bounds. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
Across 1,407 Multi-c-Si listings from Trina Solar and peers, Trina Solar TSM-310PD1408 stands 31.2 W above the 278.8 W Multi-c-Si median and typical 90.6% PTC-to-STC thermal output (280.8 W real-world rating). Sizing 6 kW (20 panels) to 10 kW (33 panels) yields $1,552-$2,560/yr in baseline US bill offset. Mid-range 45.3 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does Trina Solar TSM-310PD1408 Fall Across Listed CEC Models?
Distribution marker showing Trina Solar TSM-310PD1408 (310.0 W) relative to the 385.0 W all-CEC solar panel median. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Dataset Percentiles Define Trina Solar TSM-310PD1408?
Dataset percentiles tracking Trina Solar TSM-310PD1408 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Do the Dataset Ranks Show for Trina Solar TSM-310PD1408?
Benchmark highlights for Trina Solar TSM-310PD1408 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.14% Aperture Efficiency
Power density 161.4 W/m2 (3.77 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.36 V at -10 C (554.0 V string) and 51.8 V at -20 C (11 max).
26 Panels = 8,060 W STC
Occupies 49.9 m2 (538 sq ft) producing 7,301 W PTC; NEC 690.8 OCPD floor is 13.95 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.3 * (1 + (-0.319/100) * (-10 - 25)) = 50.36 V | OCPD = 1.56 * 8.94 = 13.95 A
Inputs from CEC Modules.csv for Trina Solar TSM-310PD1408: Voc=45.3 V, beta_Voc=-0.319%/C, Isc=8.94 A, STC=310.0 W, Area=1.921 m2.
Result: 11 panels max on 600 V (554.0 V); 26 panels for 8 kW (538 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-310PD1408?
Official CEC datasheet figures for Trina Solar TSM-310PD1408 (Multi-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 280.8 W (90.6% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.94 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.8 V / 8.42 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.319 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.14% (1.921 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-310PD1408 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Trina Solar TSM-310PD1408 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 414 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 538 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 682 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?
Consolidated Trina Solar wattage variants sharing the Trina Solar TSM-310PD1408 mechanical and cell layout. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Trina Solar TSM-300PD1408 | 300.0 W | 271.5 W | 45.1 V | 36.6 V | 15.62% |
| Trina Solar TSM-305PD1408 | 305.0 W | 276.2 W | 45.2 V | 36.7 V | 15.88% |
| Trina Solar TSM-310PD1408 | 310.0 W | 280.8 W | 45.3 V | 36.8 V | 16.14% |
| Trina Solar TSM-315PD1408 | 315.0 W | 289.5 W | 45.6 V | 37.05 V | 16.4% |
| Trina Solar TSM-320PD1408 | 320.0 W | 292.0 W | 45.8 V | 37.1 V | 16.49% |
How Many Trina Solar TSM-310PD1408 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Trina Solar TSM-310PD1408 (50.36 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.8 V | 11 panels | 569.8 V | 19 panels |
| -10 C (14 F) | 50.36 V | 11 panels | 554.0 V | 19 panels |
| 0 C (32 F) | 48.91 V | 12 panels | 586.9 V | 20 panels |
| 25 C (77 F STC) | 45.3 V | 13 panels | 588.9 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-310PD1408?
Competing CEC solar panels closest to Trina Solar TSM-310PD1408 in nameplate wattage and Voc, starting with Advance Power API-P310.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advance Power API-P310 Advance Power |
310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| Auxin Solar AXN6P612T310 Auxin Solar |
310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| Chinaland Solar Energy HSE310-72M Chinaland Solar Energy |
310.0 W | Tie (0 W) | 45.4 V | 16.06% | 90.3% |
| GCL System Integration Technology Co Ltd GCL-P6/72310 GCL System Integration Technology Co Ltd |
310.0 W | Tie (0 W) | 45.4 V | 15.98% | 90.5% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-310PD1408?
Evaluate Trina Solar TSM-310PD1408 (310.0 W STC, 45.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-310PD1408 reaches 51.8 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 538 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (538 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-310PD1408 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-310PD1408 8 kW Residential Fit
Needs 26 modules (538 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-P310.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 280.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-310PD1408 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-310PD1408?
Multiplying Trina Solar TSM-310PD1408's 8.94 A short-circuit current by 1.56 equals 13.95 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Trina Solar TSM-310PD1408 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 50.36 V cold Voc at 14 F and handles 8.94 A Isc; string inverters cap Trina Solar TSM-310PD1408 at 11 panels on 600 V.
Is Trina Solar TSM-310PD1408 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-310PD1408 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)