Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-305PA1410 — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-305PA1410 is a 305.0 W STC (276.2 W PTC) Multi-c-Si solar module ranking #16,131 of 21,677 CEC listings (below all-CEC median; higher than 23.9% of peers). It delivers 15.88% efficiency, 45.2 V Voc at 25 C, and 50.25 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
305.0 W
PTC Wattage
276.2 W
Voc @ 25C
45.2 V
Efficiency
15.88%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-305PA1410 Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-305PA1410 handles rooftop heat (276.2 W PTC), 8 kW sizing, and cold winter string voltage.

Trina Solar builds the Trina Solar TSM-305PA1410 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 158.8 W/m2 (4.03 percentage points below 19.91% CEC median). Compared against Auxin Solar AXN6P612T305G (305.0 W), this model holds typical 90.6% PTC-to-STC thermal output (276.2 W real-world rating). Mid-range 45.2 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.76 A overcurrent floor served by a 15 A breaker.

Where Does Trina Solar TSM-305PA1410 Fall Across Listed CEC Models?

Where Trina Solar TSM-305PA1410 (305.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-305PA1410 (305.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-30: 305.0 W

What Dataset Percentiles Define Trina Solar TSM-305PA1410?

Percentile placement of Trina Solar TSM-305PA1410 across power density (158.8 W/m2), thermal retention, and nameplate STC wattage.

Trina Solar TSM-305PA1410 Engineering BenchmarksPercentile comparison of Trina Solar TSM-305PA1410 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage305.0 WPTC/STC Retention90.6%Module Efficiency15.88%

What Do the Dataset Ranks Show for Trina Solar TSM-305PA1410?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-305PA1410 specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #16,131 / 21,677

305.0 W STC · Higher Than 23.9%

305.0 W STC (-80.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,341

15.88% Aperture Efficiency

Power density 158.8 W/m2 (4.03 percentage points below 19.91% CEC median). PTC/STC ratio: 90.6% (rank #17,534).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.25 V at -10 C (552.8 V string) and 51.69 V at -20 C (11 max).

8 kW Reference Array

27 Panels = 8,235 W STC

Occupies 51.9 m2 (558 sq ft) producing 7,457 W PTC; NEC 690.8 OCPD floor is 13.76 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.2 * (1 + (-0.319/100) * (-10 - 25)) = 50.25 V | OCPD = 1.56 * 8.82 = 13.76 A

Inputs from CEC Modules.csv for Trina Solar TSM-305PA1410: Voc=45.2 V, beta_Voc=-0.319%/C, Isc=8.82 A, STC=305.0 W, Area=1.921 m2.

Result: 11 panels max on 600 V (552.8 V); 27 panels for 8 kW (558 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-305PA1410?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-305PA1410.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-305PA1410.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 305.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 276.2 W (90.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.82 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.7 V / 8.31 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.319 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.88% (1.921 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Trina Solar TSM-305PA1410 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-305PA1410 (305.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.1 kW 414 sq ft $1,527 $2,582
8 kW Class 27 8.23 kW 558 sq ft $2,060 $3,483
10 kW Class 33 10.06 kW 682 sq ft $2,518 $4,258

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-305PA1410 architecture. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Trina Solar TSM-305PA1410 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-300PA1410 300.0 W 271.5 W 45.1 V 36.6 V 15.62%
Trina Solar TSM-305PA1410 305.0 W 276.2 W 45.2 V 36.7 V 15.88%
Trina Solar TSM-310PA1410 310.0 W 280.8 W 45.3 V 36.8 V 16.14%

How Many Trina Solar TSM-305PA1410 Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-305PA1410 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.2V and beta_Voc=-0.319%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.69 V 11 panels 568.6 V 19 panels
-10 C (14 F) 50.25 V 11 panels 552.8 V 19 panels
0 C (32 F) 48.8 V 12 panels 585.6 V 20 panels
25 C (77 F STC) 45.2 V 13 panels 587.6 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-305PA1410?

Alternative CEC solar modules from competing brands near Trina Solar TSM-305PA1410 (305.0 W), including Auxin Solar AXN6P612T305G. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6P612T305G
Auxin Solar
305.0 W Tie (0 W) 45.0 V 15.63% 90.3%
Advance Power API-P310
Advance Power
310.0 W +5.0 W 45.22 V 15.89% 89.5%
Auxin Solar AXN6P612T310
Auxin Solar
310.0 W +5.0 W 45.22 V 15.89% 89.5%
Centrosolar America DP72 310
Centrosolar America
310.0 W +5.0 W 45.18 V 15.94% 90.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-305PA1410?

Evaluate Trina Solar TSM-305PA1410 (305.0 W STC, 45.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-305PA1410 reaches 51.69 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 27 panels for an 8 kW build require 558 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (558 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-305PA1410 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-305PA1410 8 kW Residential Fit

Needs 27 modules (558 sq ft) with a 15 A string OCPD, offsetting ~$2,060/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6P612T305G.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 276.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-305PA1410 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-305PA1410?

Multiplying Trina Solar TSM-305PA1410's 8.82 A short-circuit current by 1.56 equals 13.76 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Trina Solar TSM-305PA1410 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.25 V cold Voc at 14 F and handles 8.82 A Isc; string inverters cap Trina Solar TSM-305PA1410 at 11 panels on 600 V.

Is Trina Solar TSM-305PA1410 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-305PA1410 rely on utility bill offset (~$2,060/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.