Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-305DD05A15(II) — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-305DD05A15(II) is a 305.0 W STC (278.4 W PTC) Mono-c-Si solar module ranking #16,131 of 21,677 CEC listings (below all-CEC median; higher than 23.9% of peers). It delivers 18.83% efficiency, 40.0 V Voc at 25 C, and 44.44 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
305.0 W
PTC Wattage
278.4 W
Voc @ 25C
40.0 V
Efficiency
18.83%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-305DD05A15(II) Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-305DD05A15(II) handles rooftop heat (278.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Trina Solar TSM-305DD05A15(II) exhibits 9.85 A short-circuit current, requiring a 15.37 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #16,131 of 21,677 (105.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 43.7 m2 for an 8 kW system (33 panels for 10 kW). Mid-range 40.0 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does Trina Solar TSM-305DD05A15(II) Fall Across Listed CEC Models?

Where Trina Solar TSM-305DD05A15(II) (305.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-305DD05A15(II) (305.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-30: 305.0 W

What Dataset Percentiles Define Trina Solar TSM-305DD05A15(II)?

Percentile placement of Trina Solar TSM-305DD05A15(II) across power density (188.3 W/m2), thermal retention, and nameplate STC wattage.

Trina Solar TSM-305DD05A15(II) Engineering BenchmarksPercentile comparison of Trina Solar TSM-305DD05A15(II) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage305.0 WPTC/STC Retention91.3%Module Efficiency18.83%

What Do the Dataset Ranks Show for Trina Solar TSM-305DD05A15(II)?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-305DD05A15(II) specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #16,131 / 21,677

305.0 W STC · Higher Than 23.9%

305.0 W STC (-80.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,772

18.83% Aperture Efficiency

Power density 188.3 W/m2 (1.08 percentage points below 19.91% CEC median). PTC/STC ratio: 91.3% (rank #16,023).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.44 V at -10 C (577.7 V string) and 45.71 V at -20 C (13 max).

8 kW Reference Array

27 Panels = 8,235 W STC

Occupies 43.7 m2 (471 sq ft) producing 7,517 W PTC; NEC 690.8 OCPD floor is 15.37 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.0 * (1 + (-0.317/100) * (-10 - 25)) = 44.44 V | OCPD = 1.56 * 9.85 = 15.37 A

Inputs from CEC Modules.csv for Trina Solar TSM-305DD05A15(II): Voc=40.0 V, beta_Voc=-0.317%/C, Isc=9.85 A, STC=305.0 W, Area=1.62 m2.

Result: 13 panels max on 600 V (577.7 V); 27 panels for 8 kW (471 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-305DD05A15(II)?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-305DD05A15(II).

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-305DD05A15(II).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 305.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 278.4 W (91.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.0 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.85 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 32.9 V / 9.28 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.317 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.83% (1.62 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Trina Solar TSM-305DD05A15(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-305DD05A15(II) (305.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.1 kW 349 sq ft $1,527 $2,582
8 kW Class 27 8.23 kW 471 sq ft $2,060 $3,483
10 kW Class 33 10.06 kW 575 sq ft $2,518 $4,258

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-305DD05A15(II) architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the Trina Solar TSM-305DD05A15(II) wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-300DD05A15(II) 300.0 W 273.7 W 39.8 V 32.6 V 18.52%
Trina Solar TSM-305DD05A15(II) 305.0 W 278.4 W 40.0 V 32.9 V 18.83%

How Many Trina Solar TSM-305DD05A15(II) Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-305DD05A15(II) from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.0V and beta_Voc=-0.317%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.71 V 13 panels 594.2 V 21 panels
-10 C (14 F) 44.44 V 13 panels 577.7 V 22 panels
0 C (32 F) 43.17 V 13 panels 561.2 V 23 panels
25 C (77 F STC) 40.0 V 15 panels 600.0 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-305DD05A15(II)?

Alternative CEC solar modules from competing brands near Trina Solar TSM-305DD05A15(II) (305.0 W), including DuCal Solar Technology LLC DST305M-60.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DuCal Solar Technology LLC DST305M-60
DuCal Solar Technology LLC
305.0 W Tie (0 W) 40.0 V 18.75% 90.3%
AXITEC AC-305M/60S
AXITEC
305.0 W Tie (0 W) 39.81 V 18.75% 91.2%
AXITEC AC-305M/60V
AXITEC
305.0 W Tie (0 W) 39.81 V 18.75% 91.2%
Enphase Energy Inc XACM-IQ7-LR6-60PB-305M
Enphase Energy Inc
305.0 W Tie (0 W) 40.2 V 19.3% 91.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-305DD05A15(II)?

Evaluate Trina Solar TSM-305DD05A15(II) (305.0 W STC, 40.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-305DD05A15(II) reaches 45.71 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 27 panels for an 8 kW build require 471 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (471 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-305DD05A15(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-305DD05A15(II) 8 kW Residential Fit

Needs 27 modules (471 sq ft) with a 20 A string OCPD, offsetting ~$2,060/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare DuCal Solar Technology LLC DST305M-60.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 278.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-305DD05A15(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Trina Solar TSM-305DD05A15(II) PTC wattage (278.4 W) lower than STC (305.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 278.4 W PTC (91.3% retention) across Trina Solar TSM-305DD05A15(II)'s 1.62 m2 aperture.

Who should skip Trina Solar TSM-305DD05A15(II) on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 27 Trina Solar TSM-305DD05A15(II) panels (471 sq ft) leave unusable roof gaps vs. DuCal Solar Technology LLC DST305M-60.

What is the 1,000 V commercial string limit for Trina Solar TSM-305DD05A15(II)?

On 1,000 V commercial inverters at -10 C (44.44 V cold Voc), Trina Solar TSM-305DD05A15(II) fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-305DD05A15(II).

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.