Trina Solar TSM-300DE05A08(II) is a 300.0 W STC (270.6 W PTC) Multi-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 18.33% efficiency, 39.9 V Voc at 25 C, and 44.75 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 300.0 W
- PTC Wattage
- 270.6 W
- Voc @ 25C
- 39.9 V
- Efficiency
- 18.33%
How Does Trina Solar TSM-300DE05A08(II) Compare Against Peer CEC Listings?
Solar engineering breakdown for Trina Solar TSM-300DE05A08(II): PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 300.0 W STC and 270.6 W PTC, Trina Solar TSM-300DE05A08(II) sits -85.0 W vs all-CEC median (below all-CEC median; higher than 22.1% of peers) among 21,677 listed modules. Power density reaches 183.3 W/m2 (1.58 percentage points below 19.91% CEC median). Lower 39.9 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, whereas 1,000 V commercial inverters handle up to 22 panels in series. Alternative peer Enphase Energy Inc XACM-IQ7-LR6-60PB-300M rates 300.0 W.
Where Does Trina Solar TSM-300DE05A08(II) Fall Across Listed CEC Models?
Distribution marker showing Trina Solar TSM-300DE05A08(II) (300.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Trina Solar TSM-300DE05A08(II)?
Dataset percentiles tracking Trina Solar TSM-300DE05A08(II) power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Trina Solar TSM-300DE05A08(II)?
Benchmark highlights for Trina Solar TSM-300DE05A08(II) covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
300.0 W STC · Higher Than 22.1%
300.0 W STC (-85.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
18.33% Aperture Efficiency
Power density 183.3 W/m2 (1.58 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.75 V at -10 C (581.8 V string) and 46.13 V at -20 C (13 max).
27 Panels = 8,100 W STC
Occupies 44.2 m2 (476 sq ft) producing 7,306 W PTC; NEC 690.8 OCPD floor is 15.04 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.9 * (1 + (-0.347/100) * (-10 - 25)) = 44.75 V | OCPD = 1.56 * 9.64 = 15.04 A
Inputs from CEC Modules.csv for Trina Solar TSM-300DE05A08(II): Voc=39.9 V, beta_Voc=-0.347%/C, Isc=9.64 A, STC=300.0 W, Area=1.637 m2.
Result: 13 panels max on 600 V (581.8 V); 27 panels for 8 kW (476 sq ft).
What Are the Published CEC Specifications for Trina Solar TSM-300DE05A08(II)?
Official CEC datasheet figures for Trina Solar TSM-300DE05A08(II) (Multi-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 300.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 270.6 W (90.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.64 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.6 V / 9.19 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.347 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.33% (1.637 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many Trina Solar TSM-300DE05A08(II) Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Trina Solar TSM-300DE05A08(II) modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.0 kW | 352 sq ft | $1,502 | $2,539 |
| 8 kW Class | 27 | 8.1 kW | 476 sq ft | $2,027 | $3,428 |
| 10 kW Class | 34 | 10.2 kW | 599 sq ft | $2,553 | $4,317 |
How Many Trina Solar TSM-300DE05A08(II) Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Trina Solar TSM-300DE05A08(II) (44.75 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.13 V | 13 panels | 599.7 V | 21 panels |
| -10 C (14 F) | 44.75 V | 13 panels | 581.8 V | 22 panels |
| 0 C (32 F) | 43.36 V | 13 panels | 563.7 V | 23 panels |
| 25 C (77 F STC) | 39.9 V | 15 panels | 598.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-300DE05A08(II)?
Competing CEC solar panels closest to Trina Solar TSM-300DE05A08(II) in nameplate wattage and Voc, starting with Enphase Energy Inc XACM-IQ7-LR6-60PB-300M.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Enphase Energy Inc XACM-IQ7-LR6-60PB-300M Enphase Energy Inc |
300.0 W | Tie (0 W) | 40.1 V | 18.99% | 91.1% |
| FreeVolt PV-GRAF-60M6-300/M FreeVolt |
300.0 W | Tie (0 W) | 39.6 V | 18.29% | 91.1% |
| CertainTeed CT300M10-03 CertainTeed |
300.0 W | Tie (0 W) | 40.3 V | 18.55% | 92.4% |
| CertainTeed CT300M11-03 CertainTeed |
300.0 W | Tie (0 W) | 40.3 V | 18.68% | 92.1% |
What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-300DE05A08(II)?
Evaluate Trina Solar TSM-300DE05A08(II) (300.0 W STC, 39.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-300DE05A08(II) reaches 46.13 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 476 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (476 sq ft).
- 2026 tax credit baseline: cash residential installs of Trina Solar TSM-300DE05A08(II) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Trina Solar TSM-300DE05A08(II) 8 kW Residential Fit
Needs 27 modules (476 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Enphase Energy Inc XACM-IQ7-LR6-60PB-300M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 270.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Trina Solar TSM-300DE05A08(II) by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Trina Solar TSM-300DE05A08(II) panels fit on a 600 V winter solar string?
At -10 C (14 F), Trina Solar TSM-300DE05A08(II) cold Voc rises from 39.9 V to 44.75 V (beta_Voc -0.347%/C), capping a 600 V string at 13 panels (581.8 V).
How much roof area does an 8 kW array of Trina Solar TSM-300DE05A08(II) need?
An 8 kW DC system uses 27 Trina Solar TSM-300DE05A08(II) modules (8,100 W STC / 7,306 W PTC), covering roughly 476 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does Trina Solar TSM-300DE05A08(II) compare against Enphase Energy Inc XACM-IQ7-LR6-60PB-300M?
Trina Solar TSM-300DE05A08(II) outputs 300.0 W STC (39.9 V Voc, rank #16,498 of 21,677), while Enphase Energy Inc XACM-IQ7-LR6-60PB-300M delivers 300.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)