Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-255PA0518 — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-255PA0518 is a 255.0 W STC (232.2 W PTC) Multi-c-Si solar module ranking #19,421 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 15.76% efficiency, 37.7 V Voc at 25 C, and 42.32 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
255.0 W
PTC Wattage
232.2 W
Voc @ 25C
37.7 V
Efficiency
15.76%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-255PA0518 Compare Against Peer CEC Listings?

How Trina Solar Trina Solar TSM-255PA0518 handles rooftop heat (232.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Trina Solar TSM-255PA0518 exhibits 8.62 A short-circuit current, requiring a 13.45 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #19,421 of 21,677 (23.8 W below the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 51.8 m2 for an 8 kW system (40 panels for 10 kW). Lower 37.7 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does Trina Solar TSM-255PA0518 Fall Across Listed CEC Models?

Where Trina Solar TSM-255PA0518 (255.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-255PA0518 (255.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-25: 255.0 W

What Dataset Percentiles Define Trina Solar TSM-255PA0518?

Percentile placement of Trina Solar TSM-255PA0518 across power density (157.6 W/m2), thermal retention, and nameplate STC wattage.

Trina Solar TSM-255PA0518 Engineering BenchmarksPercentile comparison of Trina Solar TSM-255PA0518 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage255.0 WPTC/STC Retention91.1%Module Efficiency15.76%

What Do the Dataset Ranks Show for Trina Solar TSM-255PA0518?

Four critical engineering numbers homeowners and solar installers check first when reviewing Trina Solar TSM-255PA0518 specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #19,421 / 21,677

255.0 W STC · Higher Than 9.2%

255.0 W STC (-130.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,513

15.76% Aperture Efficiency

Power density 157.6 W/m2 (4.15 percentage points below 19.91% CEC median). PTC/STC ratio: 91.1% (rank #16,462).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.32 V at -10 C (592.5 V string) and 43.64 V at -20 C (13 max).

8 kW Reference Array

32 Panels = 8,160 W STC

Occupies 51.8 m2 (557 sq ft) producing 7,430 W PTC; NEC 690.8 OCPD floor is 13.45 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.7 * (1 + (-0.35/100) * (-10 - 25)) = 42.32 V | OCPD = 1.56 * 8.62 = 13.45 A

Inputs from CEC Modules.csv for Trina Solar TSM-255PA0518: Voc=37.7 V, beta_Voc=-0.35%/C, Isc=8.62 A, STC=255.0 W, Area=1.618 m2.

Result: 14 panels max on 600 V (592.5 V); 32 panels for 8 kW (557 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-255PA0518?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Trina Solar TSM-255PA0518.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-255PA0518.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 255.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 232.2 W (91.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.62 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 31.4 V / 8.12 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.35 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.76% (1.618 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Trina Solar TSM-255PA0518 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Trina Solar TSM-255PA0518 (255.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 24 6.12 kW 418 sq ft $1,532 $2,590
8 kW Class 32 8.16 kW 557 sq ft $2,042 $3,454
10 kW Class 40 10.2 kW 697 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

All closely matched Trina Solar wattages and cosmetic trims sharing the Trina Solar TSM-255PA0518 architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Trina Solar TSM-255PA0518 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-250PA0518 250.0 W 227.5 W 37.6 V 31.0 V 15.45%
Trina Solar TSM-255PA0518 255.0 W 232.2 W 37.7 V 31.4 V 15.76%
Trina Solar TSM-260PA0518 260.0 W 236.9 W 37.9 V 31.7 V 16.07%

How Many Trina Solar TSM-255PA0518 Modules Fit in a Cold-Weather String?

Maximum series module counts for Trina Solar TSM-255PA0518 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.7V and beta_Voc=-0.35%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.64 V 13 panels 567.3 V 22 panels
-10 C (14 F) 42.32 V 14 panels 592.5 V 23 panels
0 C (32 F) 41.0 V 14 panels 574.0 V 24 panels
25 C (77 F STC) 37.7 V 15 panels 565.5 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-255PA0518?

Alternative CEC solar modules from competing brands near Trina Solar TSM-255PA0518 (255.0 W), including GCL System Integration Technology Co Ltd GCL-P6/60255.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
GCL System Integration Technology Co Ltd GCL-P6/60255
GCL System Integration Technology Co Ltd
255.0 W Tie (0 W) 37.7 V 15.67% 90.4%
Advance Power API-M255
Advance Power
255.0 W Tie (0 W) 37.68 V 15.57% 89.5%
Eoplly New Energy Technology EP156P/60-255S AC
Eoplly New Energy Technology
255.0 W Tie (0 W) 37.68 V 15.6% 89.9%
Eoplly New Energy Technology EP156M/60-255 AC
Eoplly New Energy Technology
255.0 W Tie (0 W) 37.56 V 15.76% 89.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-255PA0518?

Evaluate Trina Solar TSM-255PA0518 (255.0 W STC, 37.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-255PA0518 reaches 43.64 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 32 panels for an 8 kW build require 557 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (557 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-255PA0518 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-255PA0518 8 kW Residential Fit

Needs 32 modules (557 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-P6/60255.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 232.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-255PA0518 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Trina Solar TSM-255PA0518 PTC wattage (232.2 W) lower than STC (255.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 232.2 W PTC (91.1% retention) across Trina Solar TSM-255PA0518's 1.618 m2 aperture.

Who should skip Trina Solar TSM-255PA0518 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 32 Trina Solar TSM-255PA0518 panels (557 sq ft) leave unusable roof gaps vs. GCL System Integration Technology Co Ltd GCL-P6/60255.

What is the 1,000 V commercial string limit for Trina Solar TSM-255PA0518?

On 1,000 V commercial inverters at -10 C (42.32 V cold Voc), Trina Solar TSM-255PA0518 fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Trina Solar TSM-255PA0518.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.