Skip to main content
WireAndSun
Calculators
CEC PV Module

Trina Solar TSM-235PD0510 — CEC Solar Module Specifications

Manufacturer: Trina Solar Registry: CEC Verified Engineering Specification

Trina Solar TSM-235PD0510 is a 235.0 W STC (213.6 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.52% efficiency, 37.1 V Voc at 25 C, and 41.64 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
235.0 W
PTC Wattage
213.6 W
Voc @ 25C
37.1 V
Efficiency
14.52%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-235PD0510 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Trina Solar TSM-235PD0510 (Multi-c-Si) residential solar systems.

Trina Solar TSM-235PD0510 delivers 145.2 W/m2 (5.39 percentage points below 19.91% CEC median) and typical 90.9% PTC-to-STC thermal output (213.6 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (610 sq ft). At -4 F (-20 C), string voltage climbs to 42.94 V per unit, capping 600 V circuits at 13 panels. Compare specs directly with AXITEC AC-235P/156-60S (235.0 W).

Where Does Trina Solar TSM-235PD0510 Fall Across Listed CEC Models?

Comparison of Trina Solar TSM-235PD0510 (235.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-235PD0510 (235.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-23: 235.0 W

What Dataset Percentiles Define Trina Solar TSM-235PD0510?

Relative ranking of Trina Solar TSM-235PD0510 across nameplate watts, 90.9% PTC thermal ratio, and module aperture efficiency. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Trina Solar TSM-235PD0510 Engineering BenchmarksPercentile comparison of Trina Solar TSM-235PD0510 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage235.0 WPTC/STC Retention90.9%Module Efficiency14.52%

What Do the Dataset Ranks Show for Trina Solar TSM-235PD0510?

Summary of Trina Solar TSM-235PD0510 output rank, 8 kW array size (35 panels), efficiency rating, and 600 V string limit.

Rank #20,368 / 21,677

235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,376

14.52% Aperture Efficiency

Power density 145.2 W/m2 (5.39 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.64 V at -10 C (583.0 V string) and 42.94 V at -20 C (13 max).

8 kW Reference Array

35 Panels = 8,225 W STC

Occupies 56.6 m2 (610 sq ft) producing 7,476 W PTC; NEC 690.8 OCPD floor is 12.96 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.1 * (1 + (-0.35/100) * (-10 - 25)) = 41.64 V | OCPD = 1.56 * 8.31 = 12.96 A

Inputs from CEC Modules.csv for Trina Solar TSM-235PD0510: Voc=37.1 V, beta_Voc=-0.35%/C, Isc=8.31 A, STC=235.0 W, Area=1.618 m2.

Result: 14 panels max on 600 V (583.0 V); 35 panels for 8 kW (610 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-235PD0510?

Complete CEC test sheet for Trina Solar TSM-235PD0510 including Isc (8.31 A), Voc (37.1 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-235PD0510.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 235.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 213.6 W (90.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.31 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.1 V / 7.81 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.35 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.52% (1.618 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Trina Solar TSM-235PD0510 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Trina Solar TSM-235PD0510.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 26 6.11 kW 453 sq ft $1,529 $2,586
8 kW Class 35 8.22 kW 610 sq ft $2,057 $3,479
10 kW Class 43 10.11 kW 749 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Related Trina Solar power steps and black/silver trims consolidated into this Trina Solar TSM-235PD0510 series guide. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the Trina Solar TSM-235PD0510 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-225PD0510 225.0 W 202.1 W 36.9 V 29.4 V 13.9%
Trina Solar TSM-230PD0510 230.0 W 208.9 W 37.0 V 29.8 V 14.21%
Trina Solar TSM-235PD0510 235.0 W 213.6 W 37.1 V 30.1 V 14.52%
Trina Solar TSM-240PD0510 240.0 W 218.2 W 37.2 V 30.4 V 14.83%
Trina Solar TSM-245PD0510 245.0 W 222.9 W 37.3 V 30.7 V 15.14%

How Many Trina Solar TSM-235PD0510 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Trina Solar TSM-235PD0510 (37.1 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=37.1V and beta_Voc=-0.35%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.94 V 13 panels 558.2 V 23 panels
-10 C (14 F) 41.64 V 14 panels 583.0 V 24 panels
0 C (32 F) 40.35 V 14 panels 564.9 V 24 panels
25 C (77 F STC) 37.1 V 16 panels 593.6 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-235PD0510?

Four comparable CEC modules such as AXITEC AC-235P/156-60S (235.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-235P/156-60S
AXITEC
235.0 W Tie (0 W) 37.16 V 14.48% 90.0%
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q
Hanwha Qcells (Qidong) Co Ltd
235.0 W Tie (0 W) 37.0 V 14.54% 89.0%
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235QW
Hanwha Qcells (Qidong) Co Ltd
235.0 W Tie (0 W) 37.0 V 14.54% 89.0%
Centrosolar America DP60 235
Centrosolar America
235.0 W Tie (0 W) 36.98 V 14.33% 90.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-235PD0510?

Evaluate Trina Solar TSM-235PD0510 (235.0 W STC, 37.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-235PD0510 reaches 42.94 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 610 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (610 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-235PD0510 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-235PD0510 8 kW Residential Fit

Needs 35 modules (610 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-235P/156-60S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 213.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-235PD0510 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Trina Solar TSM-235PD0510 panels fit on a 600 V winter solar string?

At -10 C (14 F), Trina Solar TSM-235PD0510 cold Voc rises from 37.1 V to 41.64 V (beta_Voc -0.35%/C), capping a 600 V string at 14 panels (583.0 V).

How much roof area does an 8 kW array of Trina Solar TSM-235PD0510 need?

An 8 kW DC system uses 35 Trina Solar TSM-235PD0510 modules (8,225 W STC / 7,476 W PTC), covering roughly 610 sq ft and saving ~$2,057/yr at 18.54 c/kWh.

How does Trina Solar TSM-235PD0510 compare against AXITEC AC-235P/156-60S?

Trina Solar TSM-235PD0510 outputs 235.0 W STC (37.1 V Voc, rank #20,368 of 21,677), while AXITEC AC-235P/156-60S delivers 235.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.