Trina Solar TSM-235PA0528 is a 235.0 W STC (213.6 W PTC) Multi-c-Si solar module ranking #20,368 of 21,677 CEC listings (below all-CEC median; higher than 5.4% of peers). It delivers 14.52% efficiency, 37.1 V Voc at 25 C, and 41.64 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
235.0 W
PTC Wattage
213.6 W
Voc @ 25C
37.1 V
Efficiency
14.52%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Trina Solar TSM-235PA0528 Compare Against Peer CEC Listings?

Engineering position of Trina Solar TSM-235PA0528 (235.0 W STC) vs. AXITEC AC-235P/156-60S across 1,407 CEC Multi-c-Si solar modules.

Built with 60 Multi-c-Si cells, Trina Solar TSM-235PA0528 pairs typical 90.9% PTC-to-STC thermal output (213.6 W real-world rating) with 37.1 V nominal Voc. An 8 kW residential build (8,225 W DC, 7,476 W PTC) saves ~$2,057/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer AXITEC AC-235P/156-60S offers a 235.0 W alternative.

Where Does Trina Solar TSM-235PA0528 Fall Across Listed CEC Models?

Plots Trina Solar TSM-235PA0528 at 235.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Trina Solar TSM-235PA0528 (235.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTrina Solar TSM-23: 235.0 W

What Dataset Percentiles Define Trina Solar TSM-235PA0528?

Benchmarks Trina Solar TSM-235PA0528 on STC wattage, thermal PTC/STC retention, and 14.52 aperture conversion efficiency against CEC peers.

Trina Solar TSM-235PA0528 Engineering BenchmarksPercentile comparison of Trina Solar TSM-235PA0528 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage235.0 WPTC/STC Retention90.9%Module Efficiency14.52%

What Do the Dataset Ranks Show for Trina Solar TSM-235PA0528?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Trina Solar TSM-235PA0528 by Trina Solar.

Rank #20,368 / 21,677

235.0 W STC · Higher Than 5.4%

235.0 W STC (-150.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,376

14.52% Aperture Efficiency

Power density 145.2 W/m2 (5.39 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 41.64 V at -10 C (583.0 V string) and 42.94 V at -20 C (13 max).

8 kW Reference Array

35 Panels = 8,225 W STC

Occupies 56.6 m2 (610 sq ft) producing 7,476 W PTC; NEC 690.8 OCPD floor is 12.96 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.1 * (1 + (-0.35/100) * (-10 - 25)) = 41.64 V | OCPD = 1.56 * 8.31 = 12.96 A

Inputs from CEC Modules.csv for Trina Solar TSM-235PA0528: Voc=37.1 V, beta_Voc=-0.35%/C, Isc=8.31 A, STC=235.0 W, Area=1.618 m2.

Result: 14 panels max on 600 V (583.0 V); 35 panels for 8 kW (610 sq ft).

What Are the Published CEC Specifications for Trina Solar TSM-235PA0528?

Laboratory test ratings recorded for Trina Solar TSM-235PA0528 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Trina Solar TSM-235PA0528.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 235.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 213.6 W (90.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.1 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.31 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.1 V / 7.81 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.35 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.52% (1.618 m2) Array roof footprint density
Cell Count & Technology 60 cells (Multi-c-Si) Monofacial backsheet

How Many Trina Solar TSM-235PA0528 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (610 sq ft at 8 kW), and estimated Year-1 electric bill offset for Trina Solar TSM-235PA0528.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 26 6.11 kW 453 sq ft $1,529 $2,586
8 kW Class 35 8.22 kW 610 sq ft $2,057 $3,479
10 kW Class 43 10.11 kW 749 sq ft $2,530 $4,279

Which Sibling Wattage & Trim Variants Belong to This Trina Solar Series?

Sibling wattage bins and frame colors grouped with Trina Solar TSM-235PA0528 under Trina Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the Trina Solar TSM-235PA0528 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Trina Solar TSM-225PA0528 225.0 W 202.1 W 36.9 V 29.4 V 13.9%
Trina Solar TSM-230PA0528 230.0 W 208.9 W 37.0 V 29.8 V 14.21%
Trina Solar TSM-235PA0528 235.0 W 213.6 W 37.1 V 30.1 V 14.52%
Trina Solar TSM-240PA0528 240.0 W 218.2 W 37.2 V 30.4 V 14.83%
Trina Solar TSM-245PA0528 245.0 W 222.9 W 37.3 V 30.7 V 15.14%

How Many Trina Solar TSM-235PA0528 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Trina Solar TSM-235PA0528 (beta_Voc -0.35%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=37.1V and beta_Voc=-0.35%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 42.94 V 13 panels 558.2 V 23 panels
-10 C (14 F) 41.64 V 14 panels 583.0 V 24 panels
0 C (32 F) 40.35 V 14 panels 564.9 V 24 panels
25 C (77 F STC) 37.1 V 16 panels 593.6 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to Trina Solar TSM-235PA0528?

Closest cross-brand CEC competitors to Trina Solar TSM-235PA0528 matched near 235.0 W STC and 37.1 V Voc, led by AXITEC AC-235P/156-60S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-235P/156-60S
AXITEC
235.0 W Tie (0 W) 37.16 V 14.48% 90.0%
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235Q
Hanwha Qcells (Qidong) Co Ltd
235.0 W Tie (0 W) 37.0 V 14.54% 89.0%
Hanwha Qcells (Qidong) Co Ltd HSL60P6-PB-3-235QW
Hanwha Qcells (Qidong) Co Ltd
235.0 W Tie (0 W) 37.0 V 14.54% 89.0%
Centrosolar America DP60 235
Centrosolar America
235.0 W Tie (0 W) 36.98 V 14.33% 90.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Trina Solar TSM-235PA0528?

Evaluate Trina Solar TSM-235PA0528 (235.0 W STC, 37.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Trina Solar TSM-235PA0528 reaches 42.94 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 610 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (610 sq ft).
  • 2026 tax credit baseline: cash residential installs of Trina Solar TSM-235PA0528 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Trina Solar TSM-235PA0528 8 kW Residential Fit

Needs 35 modules (610 sq ft) with a 15 A string OCPD, offsetting ~$2,057/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-235P/156-60S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 213.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Trina Solar TSM-235PA0528 by Trina Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Trina Solar TSM-235PA0528?

Multiplying Trina Solar TSM-235PA0528's 8.31 A short-circuit current by 1.56 equals 12.96 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Trina Solar TSM-235PA0528 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 41.64 V cold Voc at 14 F and handles 8.31 A Isc; string inverters cap Trina Solar TSM-235PA0528 at 14 panels on 600 V.

Is Trina Solar TSM-235PA0528 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Trina Solar TSM-235PA0528 rely on utility bill offset (~$2,057/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.