Topsun Co Ltd TOP CLASS 495 is a 495.0 W STC (439.6 W PTC) Mono-c-Si solar module ranking #4,591 of 21,677 CEC listings (top 21.5%; higher than 78.5% of peers). It delivers 19.11% efficiency, 64.05 V Voc at 25 C, and 67.75 V cold Voc at -10 C (8 panels max per 600 V string).
- STC Wattage
- 495.0 W
- PTC Wattage
- 439.6 W
- Voc @ 25C
- 64.05 V
- Efficiency
- 19.11%
How Does Topsun Co Ltd TOP CLASS 495 Compare Against Peer CEC Listings?
Solar engineering breakdown for Topsun Co Ltd TOP CLASS 495: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 495.0 W STC and 439.6 W PTC, Topsun Co Ltd TOP CLASS 495 sits +110.0 W vs all-CEC median (top 21.5%; higher than 78.5% of peers) among 21,677 listed modules. Power density reaches 191.1 W/m2 (0.80 percentage points below 19.91% CEC median). Higher 64.05 V open-circuit voltage caps 600 V residential strings at 8 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 14 panels in series. Alternative peer Heliene 96M475 rates 475.0 W.
Where Does Topsun Co Ltd TOP CLASS 495 Fall Across Listed CEC Models?
Distribution marker showing Topsun Co Ltd TOP CLASS 495 (495.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Topsun Co Ltd TOP CLASS 495?
Dataset percentiles tracking Topsun Co Ltd TOP CLASS 495 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Topsun Co Ltd TOP CLASS 495?
Benchmark highlights for Topsun Co Ltd TOP CLASS 495 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 21.5% STC Output
495.0 W STC (+110.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.11% Aperture Efficiency
Power density 191.1 W/m2 (0.80 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).
8 Panels Max @ -10 C (600 V)
Cold Voc reaches 67.75 V at -10 C (542.0 V string) and 68.81 V at -20 C (8 max).
17 Panels = 8,415 W STC
Occupies 44.0 m2 (474 sq ft) producing 7,473 W PTC; NEC 690.8 OCPD floor is 15.24 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 64.05 * (1 + (-0.165/100) * (-10 - 25)) = 67.75 V | OCPD = 1.56 * 9.77 = 15.24 A
Inputs from CEC Modules.csv for Topsun Co Ltd TOP CLASS 495: Voc=64.05 V, beta_Voc=-0.165%/C, Isc=9.77 A, STC=495.0 W, Area=2.59 m2.
Result: 8 panels max on 600 V (542.0 V); 17 panels for 8 kW (474 sq ft).
What Are the Published CEC Specifications for Topsun Co Ltd TOP CLASS 495?
Official CEC datasheet figures for Topsun Co Ltd TOP CLASS 495 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 495.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 439.6 W (88.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 64.05 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.77 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 53.28 V / 9.29 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.165 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.11% (2.59 m2) | Array roof footprint density |
| Cell Count & Technology | 50 cells (Mono-c-Si) | Monofacial backsheet |
How Many Topsun Co Ltd TOP CLASS 495 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Topsun Co Ltd TOP CLASS 495 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 13 | 6.43 kW | 362 sq ft | $1,609 | $2,721 |
| 8 kW Class | 17 | 8.41 kW | 474 sq ft | $2,105 | $3,559 |
| 10 kW Class | 21 | 10.39 kW | 585 sq ft | $2,601 | $4,397 |
How Many Topsun Co Ltd TOP CLASS 495 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Topsun Co Ltd TOP CLASS 495 (67.75 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 68.81 V | 8 panels | 550.5 V | 14 panels |
| -10 C (14 F) | 67.75 V | 8 panels | 542.0 V | 14 panels |
| 0 C (32 F) | 66.69 V | 8 panels | 533.5 V | 14 panels |
| 25 C (77 F STC) | 64.05 V | 9 panels | 576.4 V | 15 panels |
Which Cross-Brand Solar Modules Compare Closest to Topsun Co Ltd TOP CLASS 495?
Competing CEC solar panels closest to Topsun Co Ltd TOP CLASS 495 in nameplate wattage and Voc, starting with Heliene 96M475.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Heliene 96M475 Heliene |
475.0 W | -20.0 W | 62.39 V | 18.85% | 90.5% |
| Heliene 96M460 Heliene |
460.0 W | -35.0 W | 61.79 V | 18.25% | 90.4% |
| CSI Solar Co Ltd CS3Y-485MS CSI Solar Co Ltd |
485.0 W | -10.0 W | 53.1 V | 21.18% | 93.6% |
| CSI Solar Co Ltd CS3Y-480P CSI Solar Co Ltd |
480.0 W | -15.0 W | 52.8 V | 20.96% | 93.2% |
What Are the Design Limits and Best-Fit Uses for Topsun Co Ltd TOP CLASS 495?
Evaluate Topsun Co Ltd TOP CLASS 495 (495.0 W STC, 64.05 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Topsun Co Ltd TOP CLASS 495 reaches 68.81 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
- Footprint constraint: 17 panels for an 8 kW build require 474 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (474 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Topsun Co Ltd TOP CLASS 495 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Topsun Co Ltd TOP CLASS 495 8 kW Residential Fit
Needs 17 modules (474 sq ft) with a 20 A string OCPD, offsetting ~$2,105/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare Heliene 96M475.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 439.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Topsun Co Ltd TOP CLASS 495 by Topsun Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Topsun Co Ltd TOP CLASS 495 panels fit on a 600 V winter solar string?
At -10 C (14 F), Topsun Co Ltd TOP CLASS 495 cold Voc rises from 64.05 V to 67.75 V (beta_Voc -0.165%/C), capping a 600 V string at 8 panels (542.0 V).
How much roof area does an 8 kW array of Topsun Co Ltd TOP CLASS 495 need?
An 8 kW DC system uses 17 Topsun Co Ltd TOP CLASS 495 modules (8,415 W STC / 7,473 W PTC), covering roughly 474 sq ft and saving ~$2,105/yr at 18.54 c/kWh.
How does Topsun Co Ltd TOP CLASS 495 compare against Heliene 96M475?
Topsun Co Ltd TOP CLASS 495 outputs 495.0 W STC (64.05 V Voc, rank #4,591 of 21,677), while Heliene 96M475 delivers 475.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)