Skip to main content
WireAndSun
Calculators
CEC PV Module

Topsun Co Ltd TOP CLASS 495 — CEC Solar Module Specifications

Manufacturer: Topsun Co Ltd Registry: CEC Verified Engineering Specification

Topsun Co Ltd TOP CLASS 495 is a 495.0 W STC (439.6 W PTC) Mono-c-Si solar module ranking #4,591 of 21,677 CEC listings (top 21.5%; higher than 78.5% of peers). It delivers 19.11% efficiency, 64.05 V Voc at 25 C, and 67.75 V cold Voc at -10 C (8 panels max per 600 V string).

STC Wattage
495.0 W
PTC Wattage
439.6 W
Voc @ 25C
64.05 V
Efficiency
19.11%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Topsun Co Ltd TOP CLASS 495 Compare Against Peer CEC Listings?

Solar engineering breakdown for Topsun Co Ltd TOP CLASS 495: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 495.0 W STC and 439.6 W PTC, Topsun Co Ltd TOP CLASS 495 sits +110.0 W vs all-CEC median (top 21.5%; higher than 78.5% of peers) among 21,677 listed modules. Power density reaches 191.1 W/m2 (0.80 percentage points below 19.91% CEC median). Higher 64.05 V open-circuit voltage caps 600 V residential strings at 8 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 14 panels in series. Alternative peer Heliene 96M475 rates 475.0 W.

Where Does Topsun Co Ltd TOP CLASS 495 Fall Across Listed CEC Models?

Distribution marker showing Topsun Co Ltd TOP CLASS 495 (495.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Topsun Co Ltd TOP CLASS 495 (495.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCTopsun Co Ltd TOP : 495.0 W

What Dataset Percentiles Define Topsun Co Ltd TOP CLASS 495?

Dataset percentiles tracking Topsun Co Ltd TOP CLASS 495 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Topsun Co Ltd TOP CLASS 495 Engineering BenchmarksPercentile comparison of Topsun Co Ltd TOP CLASS 495 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage495.0 WPTC/STC Retention88.8%Module Efficiency19.11%

What Do the Dataset Ranks Show for Topsun Co Ltd TOP CLASS 495?

Benchmark highlights for Topsun Co Ltd TOP CLASS 495 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #4,591 / 21,677

Top 21.5% STC Output

495.0 W STC (+110.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,188

19.11% Aperture Efficiency

Power density 191.1 W/m2 (0.80 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).

NEC 690.7 Limit

8 Panels Max @ -10 C (600 V)

Cold Voc reaches 67.75 V at -10 C (542.0 V string) and 68.81 V at -20 C (8 max).

8 kW Reference Array

17 Panels = 8,415 W STC

Occupies 44.0 m2 (474 sq ft) producing 7,473 W PTC; NEC 690.8 OCPD floor is 15.24 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 64.05 * (1 + (-0.165/100) * (-10 - 25)) = 67.75 V | OCPD = 1.56 * 9.77 = 15.24 A

Inputs from CEC Modules.csv for Topsun Co Ltd TOP CLASS 495: Voc=64.05 V, beta_Voc=-0.165%/C, Isc=9.77 A, STC=495.0 W, Area=2.59 m2.

Result: 8 panels max on 600 V (542.0 V); 17 panels for 8 kW (474 sq ft).

What Are the Published CEC Specifications for Topsun Co Ltd TOP CLASS 495?

Official CEC datasheet figures for Topsun Co Ltd TOP CLASS 495 (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Topsun Co Ltd TOP CLASS 495.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 495.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 439.6 W (88.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 64.05 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.77 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 53.28 V / 9.29 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.165 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.11% (2.59 m2) Array roof footprint density
Cell Count & Technology 50 cells (Mono-c-Si) Monofacial backsheet

How Many Topsun Co Ltd TOP CLASS 495 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Topsun Co Ltd TOP CLASS 495 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 13 6.43 kW 362 sq ft $1,609 $2,721
8 kW Class 17 8.41 kW 474 sq ft $2,105 $3,559
10 kW Class 21 10.39 kW 585 sq ft $2,601 $4,397

How Many Topsun Co Ltd TOP CLASS 495 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Topsun Co Ltd TOP CLASS 495 (67.75 V at 14 F).

Computed from Voc=64.05V and beta_Voc=-0.165%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 68.81 V 8 panels 550.5 V 14 panels
-10 C (14 F) 67.75 V 8 panels 542.0 V 14 panels
0 C (32 F) 66.69 V 8 panels 533.5 V 14 panels
25 C (77 F STC) 64.05 V 9 panels 576.4 V 15 panels

Which Cross-Brand Solar Modules Compare Closest to Topsun Co Ltd TOP CLASS 495?

Competing CEC solar panels closest to Topsun Co Ltd TOP CLASS 495 in nameplate wattage and Voc, starting with Heliene 96M475.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Heliene 96M475
Heliene
475.0 W -20.0 W 62.39 V 18.85% 90.5%
Heliene 96M460
Heliene
460.0 W -35.0 W 61.79 V 18.25% 90.4%
CSI Solar Co Ltd CS3Y-485MS
CSI Solar Co Ltd
485.0 W -10.0 W 53.1 V 21.18% 93.6%
CSI Solar Co Ltd CS3Y-480P
CSI Solar Co Ltd
480.0 W -15.0 W 52.8 V 20.96% 93.2%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Topsun Co Ltd TOP CLASS 495?

Evaluate Topsun Co Ltd TOP CLASS 495 (495.0 W STC, 64.05 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Topsun Co Ltd TOP CLASS 495 reaches 68.81 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 17 panels for an 8 kW build require 474 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 17 panels (474 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Topsun Co Ltd TOP CLASS 495 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Topsun Co Ltd TOP CLASS 495 8 kW Residential Fit

Needs 17 modules (474 sq ft) with a 20 A string OCPD, offsetting ~$2,105/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare Heliene 96M475.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 439.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Topsun Co Ltd TOP CLASS 495 by Topsun Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Topsun Co Ltd TOP CLASS 495 panels fit on a 600 V winter solar string?

At -10 C (14 F), Topsun Co Ltd TOP CLASS 495 cold Voc rises from 64.05 V to 67.75 V (beta_Voc -0.165%/C), capping a 600 V string at 8 panels (542.0 V).

How much roof area does an 8 kW array of Topsun Co Ltd TOP CLASS 495 need?

An 8 kW DC system uses 17 Topsun Co Ltd TOP CLASS 495 modules (8,415 W STC / 7,473 W PTC), covering roughly 474 sq ft and saving ~$2,105/yr at 18.54 c/kWh.

How does Topsun Co Ltd TOP CLASS 495 compare against Heliene 96M475?

Topsun Co Ltd TOP CLASS 495 outputs 495.0 W STC (64.05 V Voc, rank #4,591 of 21,677), while Heliene 96M475 delivers 475.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.