Manufacturer: Sunrise Solartech Registry: CEC Verified Engineering Specification

Sunrise Solartech SR-P672275 is a 275.0 W STC (244.1 W PTC) Multi-c-Si solar module ranking #18,259 of 21,677 CEC listings (below all-CEC median; higher than 14.3% of peers). It delivers 14.16% efficiency, 42.61 V Voc at 25 C, and 47.96 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
275.0 W
PTC Wattage
244.1 W
Voc @ 25C
42.61 V
Efficiency
14.16%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Sunrise Solartech SR-P672275 Compare Against Peer CEC Listings?

Solar engineering breakdown for Sunrise Solartech SR-P672275: PTC thermal retention, roof footprint, and cold Voc string bounds. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Across 1,407 Multi-c-Si listings from Sunrise Solartech and peers, Sunrise Solartech SR-P672275 stands 3.8 W below the 278.8 W Multi-c-Si median and typical 88.8% PTC-to-STC thermal output (244.1 W real-world rating). Sizing 6 kW (22 panels) to 10 kW (37 panels) yields $1,514-$2,548/yr in baseline US bill offset. Mid-range 42.61 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does Sunrise Solartech SR-P672275 Fall Across Listed CEC Models?

Distribution marker showing Sunrise Solartech SR-P672275 (275.0 W) relative to the 385.0 W all-CEC solar panel median. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Sunrise Solartech SR-P672275 (275.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSunrise Solartech : 275.0 W

What Dataset Percentiles Define Sunrise Solartech SR-P672275?

Dataset percentiles tracking Sunrise Solartech SR-P672275 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sunrise Solartech SR-P672275 Engineering BenchmarksPercentile comparison of Sunrise Solartech SR-P672275 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage275.0 WPTC/STC Retention88.8%Module Efficiency14.16%

What Do the Dataset Ranks Show for Sunrise Solartech SR-P672275?

Benchmark highlights for Sunrise Solartech SR-P672275 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #18,259 / 21,677

275.0 W STC · Higher Than 14.3%

275.0 W STC (-110.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,764

14.16% Aperture Efficiency

Power density 141.6 W/m2 (5.75 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 47.96 V at -10 C (575.5 V string) and 49.49 V at -20 C (12 max).

8 kW Reference Array

30 Panels = 8,250 W STC

Occupies 58.3 m2 (627 sq ft) producing 7,323 W PTC; NEC 690.8 OCPD floor is 13.45 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 42.61 * (1 + (-0.359/100) * (-10 - 25)) = 47.96 V | OCPD = 1.56 * 8.62 = 13.45 A

Inputs from CEC Modules.csv for Sunrise Solartech SR-P672275: Voc=42.61 V, beta_Voc=-0.359%/C, Isc=8.62 A, STC=275.0 W, Area=1.942 m2.

Result: 12 panels max on 600 V (575.5 V); 30 panels for 8 kW (627 sq ft).

What Are the Published CEC Specifications for Sunrise Solartech SR-P672275?

Official CEC datasheet figures for Sunrise Solartech SR-P672275 (Multi-c-Si) used in utility interconnection and permit reviews. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Official California Energy Commission (NREL SAM) test parameters for Sunrise Solartech SR-P672275.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 275.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 244.1 W (88.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 42.61 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.62 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.5 V / 7.98 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.359 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.16% (1.942 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Sunrise Solartech SR-P672275 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Sunrise Solartech SR-P672275 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.05 kW 460 sq ft $1,514 $2,561
8 kW Class 30 8.25 kW 627 sq ft $2,065 $3,492
10 kW Class 37 10.18 kW 773 sq ft $2,548 $4,308

How Many Sunrise Solartech SR-P672275 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Sunrise Solartech SR-P672275 (47.96 V at 14 F).

Computed from Voc=42.61V and beta_Voc=-0.359%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 49.49 V 12 panels 593.9 V 20 panels
-10 C (14 F) 47.96 V 12 panels 575.5 V 20 panels
0 C (32 F) 46.43 V 12 panels 557.2 V 21 panels
25 C (77 F STC) 42.61 V 14 panels 596.5 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to Sunrise Solartech SR-P672275?

Competing CEC solar panels closest to Sunrise Solartech SR-P672275 in nameplate wattage and Voc, starting with Anhui Rinengzhongtian Semiconductor Development QJM270-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Anhui Rinengzhongtian Semiconductor Development QJM270-72
Anhui Rinengzhongtian Semiconductor Development
270.0 W -5.0 W 43.67 V 13.92% 89.6%
Centrosolar America DP72 270
Centrosolar America
270.0 W -5.0 W 43.85 V 13.89% 88.4%
Anhui Rinengzhongtian Semiconductor Development QJP265-72
Anhui Rinengzhongtian Semiconductor Development
265.0 W -10.0 W 42.3 V 13.66% 89.1%
AXITEC AC-270P/156-72S
AXITEC
270.0 W -5.0 W 44.18 V 13.94% 89.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Sunrise Solartech SR-P672275?

Evaluate Sunrise Solartech SR-P672275 (275.0 W STC, 42.61 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Sunrise Solartech SR-P672275 reaches 49.49 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 30 panels for an 8 kW build require 627 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 30 panels (627 sq ft).
  • 2026 tax credit baseline: cash residential installs of Sunrise Solartech SR-P672275 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Sunrise Solartech SR-P672275 8 kW Residential Fit

Needs 30 modules (627 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare Anhui Rinengzhongtian Semiconductor Development QJM270-72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 244.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Sunrise Solartech SR-P672275 by Sunrise Solartech grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Sunrise Solartech SR-P672275?

Multiplying Sunrise Solartech SR-P672275's 8.62 A short-circuit current by 1.56 equals 13.45 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Sunrise Solartech SR-P672275 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 47.96 V cold Voc at 14 F and handles 8.62 A Isc; string inverters cap Sunrise Solartech SR-P672275 at 12 panels on 600 V.

Is Sunrise Solartech SR-P672275 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Sunrise Solartech SR-P672275 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.