Skip to main content
WireAndSun
Calculators
CEC PV Module

Star Solar Inc STAR-440W-m72HB — CEC Solar Module Specifications

Manufacturer: Star Solar Inc Registry: CEC Verified Engineering Specification

Star Solar Inc STAR-440W-m72HB is a 440.0 W STC (411.1 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 19.91% efficiency, 50.5 V Voc at 25 C, and 55.96 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
440.0 W
PTC Wattage
411.1 W
Voc @ 25C
50.5 V
Efficiency
19.91%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Star Solar Inc STAR-440W-m72HB Compare Against Peer CEC Listings?

Solar engineering breakdown for Star Solar Inc STAR-440W-m72HB: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Star Solar Inc and peers, Star Solar Inc STAR-440W-m72HB stands 30.0 W above the 410.0 W Mono-c-Si median and strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,542-$2,533/yr in baseline US bill offset. Higher 50.5 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does Star Solar Inc STAR-440W-m72HB Fall Across Listed CEC Models?

Distribution marker showing Star Solar Inc STAR-440W-m72HB (440.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Star Solar Inc STAR-440W-m72HB (440.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCStar Solar Inc STA: 440.0 W

What Dataset Percentiles Define Star Solar Inc STAR-440W-m72HB?

Dataset percentiles tracking Star Solar Inc STAR-440W-m72HB power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Star Solar Inc STAR-440W-m72HB Engineering BenchmarksPercentile comparison of Star Solar Inc STAR-440W-m72HB wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage440.0 WPTC/STC Retention93.4%Module Efficiency19.91%

What Do the Dataset Ranks Show for Star Solar Inc STAR-440W-m72HB?

Benchmark highlights for Star Solar Inc STAR-440W-m72HB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #6,418 / 21,677

Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,818

19.91% Aperture Efficiency

Power density 199.1 W/m2 (equal to 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.96 V at -10 C (559.6 V string) and 57.52 V at -20 C (10 max).

8 kW Reference Array

19 Panels = 8,360 W STC

Occupies 42.0 m2 (452 sq ft) producing 7,811 W PTC; NEC 690.8 OCPD floor is 17.69 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.5 * (1 + (-0.309/100) * (-10 - 25)) = 55.96 V | OCPD = 1.56 * 11.34 = 17.69 A

Inputs from CEC Modules.csv for Star Solar Inc STAR-440W-m72HB: Voc=50.5 V, beta_Voc=-0.309%/C, Isc=11.34 A, STC=440.0 W, Area=2.21 m2.

Result: 10 panels max on 600 V (559.6 V); 19 panels for 8 kW (452 sq ft).

What Are the Published CEC Specifications for Star Solar Inc STAR-440W-m72HB?

Official CEC datasheet figures for Star Solar Inc STAR-440W-m72HB (Mono-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Official California Energy Commission (NREL SAM) test parameters for Star Solar Inc STAR-440W-m72HB.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 440.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 411.1 W (93.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.34 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.81 V / 10.52 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.309 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.91% (2.21 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Star Solar Inc STAR-440W-m72HB Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Star Solar Inc STAR-440W-m72HB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.16 kW 333 sq ft $1,542 $2,607
8 kW Class 19 8.36 kW 452 sq ft $2,092 $3,538
10 kW Class 23 10.12 kW 547 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Star Solar Inc Series?

Consolidated Star Solar Inc wattage variants sharing the Star Solar Inc STAR-440W-m72HB mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the Star Solar Inc STAR-440W-m72HB wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Star Solar Inc STAR-435W-m72HB 435.0 W 406.3 W 50.35 V 41.66 V 19.68%
Star Solar Inc STAR-440W-m72HB 440.0 W 411.1 W 50.5 V 41.81 V 19.91%
Star Solar Inc STAR-445W-m72HB 445.0 W 415.9 W 50.58 V 41.96 V 20.14%

How Many Star Solar Inc STAR-440W-m72HB Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Star Solar Inc STAR-440W-m72HB (55.96 V at 14 F).

Computed from Voc=50.5V and beta_Voc=-0.309%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 57.52 V 10 panels 575.2 V 17 panels
-10 C (14 F) 55.96 V 10 panels 559.6 V 17 panels
0 C (32 F) 54.4 V 11 panels 598.4 V 18 panels
25 C (77 F STC) 50.5 V 11 panels 555.5 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Star Solar Inc STAR-440W-m72HB?

Competing CEC solar panels closest to Star Solar Inc STAR-440W-m72HB in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
440.0 W Tie (0 W) 49.6 V 20.75% 92.4%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-440W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
440.0 W Tie (0 W) 49.3 V 20.56% 92.6%
Apollo Renewables Inc Apollo-M672BH-440TW
Apollo Renewables Inc
440.0 W Tie (0 W) 49.2 V 20.47% 93.4%
Bluesun Solar CoLtd BSM440M-72HPH
Bluesun Solar CoLtd
440.0 W Tie (0 W) 49.2 V 20.28% 92.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Star Solar Inc STAR-440W-m72HB?

Evaluate Star Solar Inc STAR-440W-m72HB (440.0 W STC, 50.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Star Solar Inc STAR-440W-m72HB reaches 57.52 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 452 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (452 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Star Solar Inc STAR-440W-m72HB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Star Solar Inc STAR-440W-m72HB 8 kW Residential Fit

Needs 19 modules (452 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 411.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Star Solar Inc STAR-440W-m72HB by Star Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Star Solar Inc STAR-440W-m72HB?

Multiplying Star Solar Inc STAR-440W-m72HB's 11.34 A short-circuit current by 1.56 equals 17.69 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Star Solar Inc STAR-440W-m72HB pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 55.96 V cold Voc at 14 F and handles 11.34 A Isc; string inverters cap Star Solar Inc STAR-440W-m72HB at 10 panels on 600 V.

Is Star Solar Inc STAR-440W-m72HB eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Star Solar Inc STAR-440W-m72HB rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.