Star Solar Inc STAR-445W-m72HBi — CEC Solar Module Specifications

Manufacturer: Star Solar Inc Registry: CEC Verified Engineering Specification

Star Solar Inc STAR-445W-m72HBi is a 445.0 W STC (416.2 W PTC) Mono-c-Si solar module ranking #6,028 of 21,677 CEC listings (top 29.6%; higher than 70.4% of peers). It delivers 20.14% efficiency, 50.58 V Voc at 25 C, and 55.8 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
445.0 W
PTC Wattage
416.2 W
Voc @ 25C
50.58 V
Efficiency
20.14%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Star Solar Inc STAR-445W-m72HBi Compare Against Peer CEC Listings?

How Star Solar Inc Star Solar Inc STAR-445W-m72HBi handles rooftop heat (416.2 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Star Solar Inc STAR-445W-m72HBi exhibits 11.37 A short-circuit current, requiring a 17.74 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #6,028 of 21,677 (35.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 39.8 m2 for an 8 kW system (23 panels for 10 kW). Higher 50.58 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does Star Solar Inc STAR-445W-m72HBi Fall Across Listed CEC Models?

Where Star Solar Inc STAR-445W-m72HBi (445.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Star Solar Inc STAR-445W-m72HBi (445.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCStar Solar Inc STA: 445.0 W

What Dataset Percentiles Define Star Solar Inc STAR-445W-m72HBi?

Percentile placement of Star Solar Inc STAR-445W-m72HBi across power density (201.4 W/m2), thermal retention, and nameplate STC wattage.

Star Solar Inc STAR-445W-m72HBi Engineering BenchmarksPercentile comparison of Star Solar Inc STAR-445W-m72HBi wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage445.0 WPTC/STC Retention93.5%Module Efficiency20.14%

What Do the Dataset Ranks Show for Star Solar Inc STAR-445W-m72HBi?

Four critical engineering numbers homeowners and solar installers check first when reviewing Star Solar Inc STAR-445W-m72HBi specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #6,028 / 21,677

Top 29.6% STC Output

445.0 W STC (+60.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,983

20.14% Aperture Efficiency

Power density 201.4 W/m2 (0.23 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.8 V at -10 C (558.0 V string) and 57.29 V at -20 C (10 max).

8 kW Reference Array

18 Panels = 8,010 W STC

Occupies 39.8 m2 (428 sq ft) producing 7,492 W PTC; NEC 690.8 OCPD floor is 17.74 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.58 * (1 + (-0.295/100) * (-10 - 25)) = 55.8 V | OCPD = 1.56 * 11.37 = 17.74 A

Inputs from CEC Modules.csv for Star Solar Inc STAR-445W-m72HBi: Voc=50.58 V, beta_Voc=-0.295%/C, Isc=11.37 A, STC=445.0 W, Area=2.21 m2.

Result: 10 panels max on 600 V (558.0 V); 18 panels for 8 kW (428 sq ft).

What Are the Published CEC Specifications for Star Solar Inc STAR-445W-m72HBi?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Star Solar Inc STAR-445W-m72HBi.

Official California Energy Commission (NREL SAM) test parameters for Star Solar Inc STAR-445W-m72HBi.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 445.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 416.2 W (93.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.58 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.37 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.96 V / 10.61 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.295 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.14% (2.21 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Star Solar Inc STAR-445W-m72HBi Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Star Solar Inc STAR-445W-m72HBi (445.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.23 kW 333 sq ft $1,559 $2,637
8 kW Class 18 8.01 kW 428 sq ft $2,005 $3,390
10 kW Class 23 10.23 kW 547 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Star Solar Inc Series?

All closely matched Star Solar Inc wattages and cosmetic trims sharing the Star Solar Inc STAR-445W-m72HBi architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the Star Solar Inc STAR-445W-m72HBi wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Star Solar Inc STAR-440W-m72HBi 440.0 W 411.4 W 50.5 V 41.81 V 19.91%
Star Solar Inc STAR-445W-m72HBi 445.0 W 416.2 W 50.58 V 41.96 V 20.14%

How Many Star Solar Inc STAR-445W-m72HBi Modules Fit in a Cold-Weather String?

Maximum series module counts for Star Solar Inc STAR-445W-m72HBi from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=50.58V and beta_Voc=-0.295%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 57.29 V 10 panels 572.9 V 17 panels
-10 C (14 F) 55.8 V 10 panels 558.0 V 17 panels
0 C (32 F) 54.31 V 11 panels 597.4 V 18 panels
25 C (77 F STC) 50.58 V 11 panels 556.4 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Star Solar Inc STAR-445W-m72HBi?

Alternative CEC solar modules from competing brands near Star Solar Inc STAR-445W-m72HBi (445.0 W), including Bright Spot Solar LLC BRIGHTSPOT-445W-m72HBi.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bright Spot Solar LLC BRIGHTSPOT-445W-m72HBi
Bright Spot Solar LLC
445.0 W Tie (0 W) 50.6 V 20.14% 93.5%
Bluesun Solar CoLtd BSM440M-72HBD
Bluesun Solar CoLtd
440.0 W -5.0 W 50.0 V 20.28% 92.7%
CSI Solar Co Ltd CS3Y-440PB-AG
CSI Solar Co Ltd
440.0 W -5.0 W 51.2 V 19.13% 93.7%
Aptos Solar Technology LLC DNA-144-BF26-435W
Aptos Solar Technology LLC
435.0 W -10.0 W 49.38 V 20.71% 92.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Star Solar Inc STAR-445W-m72HBi?

Evaluate Star Solar Inc STAR-445W-m72HBi (445.0 W STC, 50.58 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Star Solar Inc STAR-445W-m72HBi reaches 57.29 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 428 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (428 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Star Solar Inc STAR-445W-m72HBi carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Star Solar Inc STAR-445W-m72HBi 8 kW Residential Fit

Needs 18 modules (428 sq ft) with a 20 A string OCPD, offsetting ~$2,005/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Bright Spot Solar LLC BRIGHTSPOT-445W-m72HBi.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 416.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Star Solar Inc STAR-445W-m72HBi by Star Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Star Solar Inc STAR-445W-m72HBi PTC wattage (416.2 W) lower than STC (445.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 416.2 W PTC (93.5% retention) across Star Solar Inc STAR-445W-m72HBi's 2.21 m2 aperture.

Who should skip Star Solar Inc STAR-445W-m72HBi on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 Star Solar Inc STAR-445W-m72HBi panels (428 sq ft) leave unusable roof gaps vs. Bright Spot Solar LLC BRIGHTSPOT-445W-m72HBi.

What is the 1,000 V commercial string limit for Star Solar Inc STAR-445W-m72HBi?

On 1,000 V commercial inverters at -10 C (55.8 V cold Voc), Star Solar Inc STAR-445W-m72HBi fits up to 17 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Star Solar Inc STAR-445W-m72HBi.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.