Solaria Corporation Solaria PowerXT-395R-PM-AC is a 395.0 W STC (359.4 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 19.95% efficiency, 50.7 V Voc at 25 C, and 56.5 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 359.4 W
- Voc @ 25C
- 50.7 V
- Efficiency
- 19.95%
How Does Solaria Corporation Solaria PowerXT-395R-PM-AC Compare Against Peer CEC Listings?
How Solaria Corporation Solaria Corporation Solaria PowerXT-395R-PM-AC handles rooftop heat (359.4 W PTC), 8 kW sizing, and cold winter string voltage.
Solaria Corporation builds the Solaria Corporation Solaria PowerXT-395R-PM-AC (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 199.5 W/m2 (0.04 percentage points above 19.91% CEC median). Compared against BYD Company Limited BYD415MIK-36 (395.0 W), this model holds typical 91.0% PTC-to-STC thermal output (359.4 W real-world rating). Higher 50.7 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 15.26 A overcurrent floor served by a 20 A breaker.
Where Does Solaria Corporation Solaria PowerXT-395R-PM-AC Fall Across Listed CEC Models?
Where Solaria Corporation Solaria PowerXT-395R-PM-AC (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Solaria Corporation Solaria PowerXT-395R-PM-AC?
Percentile placement of Solaria Corporation Solaria PowerXT-395R-PM-AC across power density (199.5 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Solaria Corporation Solaria PowerXT-395R-PM-AC?
Four critical engineering numbers homeowners and solar installers check first when reviewing Solaria Corporation Solaria PowerXT-395R-PM-AC specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.95% Aperture Efficiency
Power density 199.5 W/m2 (0.04 percentage points above 19.91% CEC median). PTC/STC ratio: 91.0% (rank #16,685).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 56.5 V at -10 C (565.0 V string) and 58.16 V at -20 C (10 max).
21 Panels = 8,295 W STC
Occupies 41.6 m2 (448 sq ft) producing 7,547 W PTC; NEC 690.8 OCPD floor is 15.26 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 50.7 * (1 + (-0.327/100) * (-10 - 25)) = 56.5 V | OCPD = 1.56 * 9.78 = 15.26 A
Inputs from CEC Modules.csv for Solaria Corporation Solaria PowerXT-395R-PM-AC: Voc=50.7 V, beta_Voc=-0.327%/C, Isc=9.78 A, STC=395.0 W, Area=1.98 m2.
Result: 10 panels max on 600 V (565.0 V); 21 panels for 8 kW (448 sq ft).
What Are the Published CEC Specifications for Solaria Corporation Solaria PowerXT-395R-PM-AC?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Solaria Corporation Solaria PowerXT-395R-PM-AC.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 359.4 W (91.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 50.7 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.78 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.13 V / 9.38 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.327 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.95% (1.98 m2) | Array roof footprint density |
| Cell Count & Technology | 38 cells (Mono-c-Si) | Monofacial backsheet |
How Many Solaria Corporation Solaria PowerXT-395R-PM-AC Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Solaria Corporation Solaria PowerXT-395R-PM-AC (395.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 341 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 448 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 554 sq ft | $2,570 | $4,347 |
How Many Solaria Corporation Solaria PowerXT-395R-PM-AC Modules Fit in a Cold-Weather String?
Maximum series module counts for Solaria Corporation Solaria PowerXT-395R-PM-AC from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 58.16 V | 10 panels | 581.6 V | 17 panels |
| -10 C (14 F) | 56.5 V | 10 panels | 565.0 V | 17 panels |
| 0 C (32 F) | 54.84 V | 10 panels | 548.4 V | 18 panels |
| 25 C (77 F STC) | 50.7 V | 11 panels | 557.7 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Solaria Corporation Solaria PowerXT-395R-PM-AC?
Alternative CEC solar modules from competing brands near Solaria Corporation Solaria PowerXT-395R-PM-AC (395.0 W), including BYD Company Limited BYD415MIK-36.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| BYD Company Limited BYD415MIK-36 BYD Company Limited |
395.0 W | Tie (0 W) | 50.06 V | 19.65% | 93.9% |
| ELITE Solar ET-M672BH395GL ELITE Solar |
395.0 W | Tie (0 W) | 49.6 V | 19.36% | 93.2% |
| ELITE Solar ET-M672BH395WW ELITE Solar |
395.0 W | Tie (0 W) | 49.5 V | 19.85% | 93.3% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-BHC-395W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
395.0 W | Tie (0 W) | 48.7 V | 20.26% | 92.9% |
What Are the Design Limits and Best-Fit Uses for Solaria Corporation Solaria PowerXT-395R-PM-AC?
Evaluate Solaria Corporation Solaria PowerXT-395R-PM-AC (395.0 W STC, 50.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Solaria Corporation Solaria PowerXT-395R-PM-AC reaches 58.16 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 448 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (448 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Solaria Corporation Solaria PowerXT-395R-PM-AC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Solaria Corporation Solaria PowerXT-395R-PM-AC 8 kW Residential Fit
Needs 21 modules (448 sq ft) with a 20 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare BYD Company Limited BYD415MIK-36.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 359.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Solaria Corporation Solaria PowerXT-395R-PM-AC by Solaria Corporation grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Solaria Corporation Solaria PowerXT-395R-PM-AC?
Multiplying Solaria Corporation Solaria PowerXT-395R-PM-AC's 9.78 A short-circuit current by 1.56 equals 15.26 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Solaria Corporation Solaria PowerXT-395R-PM-AC pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 56.5 V cold Voc at 14 F and handles 9.78 A Isc; string inverters cap Solaria Corporation Solaria PowerXT-395R-PM-AC at 10 panels on 600 V.
Is Solaria Corporation Solaria PowerXT-395R-PM-AC eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Solaria Corporation Solaria PowerXT-395R-PM-AC rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)