Solaria Corporation Solaria PowerXT-365R-AC is a 365.0 W STC (332.4 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 20.17% efficiency, 48.0 V Voc at 25 C, and 53.19 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 365.0 W
- PTC Wattage
- 332.4 W
- Voc @ 25C
- 48.0 V
- Efficiency
- 20.17%
How Does Solaria Corporation Solaria PowerXT-365R-AC Compare Against Peer CEC Listings?
Engineering position of Solaria Corporation Solaria PowerXT-365R-AC (365.0 W STC) vs. Caterpillar Inc PVC365MP03 across 5,889 CEC Mono-c-Si solar modules.
Built with 36 Mono-c-Si cells, Solaria Corporation Solaria PowerXT-365R-AC pairs typical 91.1% PTC-to-STC thermal output (332.4 W real-world rating) with 48.0 V nominal Voc. An 8 kW residential build (8,030 W DC, 7,313 W PTC) saves ~$2,010/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Caterpillar Inc PVC365MP03 offers a 365.0 W alternative.
Where Does Solaria Corporation Solaria PowerXT-365R-AC Fall Across Listed CEC Models?
Plots Solaria Corporation Solaria PowerXT-365R-AC at 365.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Solaria Corporation Solaria PowerXT-365R-AC?
Benchmarks Solaria Corporation Solaria PowerXT-365R-AC on STC wattage, thermal PTC/STC retention, and 20.17 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Solaria Corporation Solaria PowerXT-365R-AC?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Solaria Corporation Solaria PowerXT-365R-AC by Solaria Corporation.
365.0 W STC · Higher Than 42.9%
365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.17% Aperture Efficiency
Power density 201.7 W/m2 (0.26 percentage points above 19.91% CEC median). PTC/STC ratio: 91.1% (rank #16,462).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.19 V at -10 C (585.1 V string) and 54.67 V at -20 C (10 max).
22 Panels = 8,030 W STC
Occupies 39.8 m2 (429 sq ft) producing 7,313 W PTC; NEC 690.8 OCPD floor is 14.94 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.0 * (1 + (-0.309/100) * (-10 - 25)) = 53.19 V | OCPD = 1.56 * 9.58 = 14.94 A
Inputs from CEC Modules.csv for Solaria Corporation Solaria PowerXT-365R-AC: Voc=48.0 V, beta_Voc=-0.309%/C, Isc=9.58 A, STC=365.0 W, Area=1.81 m2.
Result: 11 panels max on 600 V (585.1 V); 22 panels for 8 kW (429 sq ft).
What Are the Published CEC Specifications for Solaria Corporation Solaria PowerXT-365R-AC?
Laboratory test ratings recorded for Solaria Corporation Solaria PowerXT-365R-AC (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 365.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 332.4 W (91.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.58 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.9 V / 9.16 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.309 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.17% (1.81 m2) | Array roof footprint density |
| Cell Count & Technology | 36 cells (Mono-c-Si) | Monofacial backsheet |
How Many Solaria Corporation Solaria PowerXT-365R-AC Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (429 sq ft at 8 kW), and estimated Year-1 electric bill offset for Solaria Corporation Solaria PowerXT-365R-AC.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.21 kW | 331 sq ft | $1,554 | $2,628 |
| 8 kW Class | 22 | 8.03 kW | 429 sq ft | $2,010 | $3,398 |
| 10 kW Class | 28 | 10.22 kW | 546 sq ft | $2,558 | $4,325 |
How Many Solaria Corporation Solaria PowerXT-365R-AC Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Solaria Corporation Solaria PowerXT-365R-AC (beta_Voc -0.309%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.67 V | 10 panels | 546.7 V | 18 panels |
| -10 C (14 F) | 53.19 V | 11 panels | 585.1 V | 18 panels |
| 0 C (32 F) | 51.71 V | 11 panels | 568.8 V | 19 panels |
| 25 C (77 F STC) | 48.0 V | 12 panels | 576.0 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Solaria Corporation Solaria PowerXT-365R-AC?
Closest cross-brand CEC competitors to Solaria Corporation Solaria PowerXT-365R-AC matched near 365.0 W STC and 48.0 V Voc, led by Caterpillar Inc PVC365MP03.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Caterpillar Inc PVC365MP03 Caterpillar Inc |
365.0 W | Tie (0 W) | 48.13 V | 19.41% | 93.4% |
| CertainTeed CT365M10-03 CertainTeed |
365.0 W | Tie (0 W) | 47.8 V | 18.98% | 91.6% |
| CertainTeed CT365M10-02 CertainTeed |
365.0 W | Tie (0 W) | 47.66 V | 19.39% | 91.9% |
| CertainTeed CT365M11-02 CertainTeed |
365.0 W | Tie (0 W) | 47.66 V | 19.39% | 91.4% |
What Are the Design Limits and Best-Fit Uses for Solaria Corporation Solaria PowerXT-365R-AC?
Evaluate Solaria Corporation Solaria PowerXT-365R-AC (365.0 W STC, 48.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Solaria Corporation Solaria PowerXT-365R-AC reaches 54.67 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 429 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (429 sq ft).
- 2026 tax credit baseline: cash residential installs of Solaria Corporation Solaria PowerXT-365R-AC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Solaria Corporation Solaria PowerXT-365R-AC 8 kW Residential Fit
Needs 22 modules (429 sq ft) with a 15 A string OCPD, offsetting ~$2,010/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Caterpillar Inc PVC365MP03.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 332.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Solaria Corporation Solaria PowerXT-365R-AC by Solaria Corporation grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Solaria Corporation Solaria PowerXT-365R-AC?
Multiplying Solaria Corporation Solaria PowerXT-365R-AC's 9.58 A short-circuit current by 1.56 equals 14.94 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Solaria Corporation Solaria PowerXT-365R-AC pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.19 V cold Voc at 14 F and handles 9.58 A Isc; string inverters cap Solaria Corporation Solaria PowerXT-365R-AC at 11 panels on 600 V.
Is Solaria Corporation Solaria PowerXT-365R-AC eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Solaria Corporation Solaria PowerXT-365R-AC rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)