Skip to main content
WireAndSun
Calculators
CEC PV Module

Solaria Corporation Solaria PowerXT-355R-BD — CEC Solar Module Specifications

Manufacturer: Solaria Corporation Registry: CEC Verified Engineering Specification

Solaria Corporation Solaria PowerXT-355R-BD is a 355.0 W STC (323.0 W PTC) Mono-c-Si solar module ranking #12,724 of 21,677 CEC listings (below all-CEC median; higher than 39.9% of peers). It delivers 19.61% efficiency, 47.7 V Voc at 25 C, and 52.71 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
355.0 W
PTC Wattage
323.0 W
Voc @ 25C
47.7 V
Efficiency
19.61%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solaria Corporation Solaria PowerXT-355R-BD Compare Against Peer CEC Listings?

How Solaria Corporation Solaria Corporation Solaria PowerXT-355R-BD handles rooftop heat (323.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Solaria Corporation Solaria PowerXT-355R-BD exhibits 9.48 A short-circuit current, requiring a 14.79 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #12,724 of 21,677 (55.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 41.6 m2 for an 8 kW system (29 panels for 10 kW). Mid-range 47.7 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does Solaria Corporation Solaria PowerXT-355R-BD Fall Across Listed CEC Models?

Where Solaria Corporation Solaria PowerXT-355R-BD (355.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solaria Corporation Solaria PowerXT-355R-BD (355.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolaria Corporatio: 355.0 W

What Dataset Percentiles Define Solaria Corporation Solaria PowerXT-355R-BD?

Percentile placement of Solaria Corporation Solaria PowerXT-355R-BD across power density (196.1 W/m2), thermal retention, and nameplate STC wattage.

Solaria Corporation Solaria PowerXT-355R-BD Engineering BenchmarksPercentile comparison of Solaria Corporation Solaria PowerXT-355R-BD wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage355.0 WPTC/STC Retention91.0%Module Efficiency19.61%

What Do the Dataset Ranks Show for Solaria Corporation Solaria PowerXT-355R-BD?

Four critical engineering numbers homeowners and solar installers check first when reviewing Solaria Corporation Solaria PowerXT-355R-BD specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #12,724 / 21,677

355.0 W STC · Higher Than 39.9%

355.0 W STC (-30.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #11,817

19.61% Aperture Efficiency

Power density 196.1 W/m2 (0.30 percentage points below 19.91% CEC median). PTC/STC ratio: 91.0% (rank #16,685).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.71 V at -10 C (579.8 V string) and 54.14 V at -20 C (11 max).

8 kW Reference Array

23 Panels = 8,165 W STC

Occupies 41.6 m2 (448 sq ft) producing 7,429 W PTC; NEC 690.8 OCPD floor is 14.79 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.7 * (1 + (-0.3/100) * (-10 - 25)) = 52.71 V | OCPD = 1.56 * 9.48 = 14.79 A

Inputs from CEC Modules.csv for Solaria Corporation Solaria PowerXT-355R-BD: Voc=47.7 V, beta_Voc=-0.3%/C, Isc=9.48 A, STC=355.0 W, Area=1.81 m2.

Result: 11 panels max on 600 V (579.8 V); 23 panels for 8 kW (448 sq ft).

What Are the Published CEC Specifications for Solaria Corporation Solaria PowerXT-355R-BD?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Solaria Corporation Solaria PowerXT-355R-BD.

Official California Energy Commission (NREL SAM) test parameters for Solaria Corporation Solaria PowerXT-355R-BD.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 355.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 323.0 W (91.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.48 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.5 V / 8.99 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.3 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.61% (1.81 m2) Array roof footprint density
Cell Count & Technology 360 cells (Mono-c-Si) Monofacial backsheet

How Many Solaria Corporation Solaria PowerXT-355R-BD Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Solaria Corporation Solaria PowerXT-355R-BD (355.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.04 kW 331 sq ft $1,512 $2,556
8 kW Class 23 8.16 kW 448 sq ft $2,042 $3,454
10 kW Class 29 10.29 kW 565 sq ft $2,575 $4,355

Which Sibling Wattage & Trim Variants Belong to This Solaria Corporation Series?

All closely matched Solaria Corporation wattages and cosmetic trims sharing the Solaria Corporation Solaria PowerXT-355R-BD architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the Solaria Corporation Solaria PowerXT-355R-BD wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Solaria Corporation Solaria PowerXT-350R-BD 350.0 W 318.2 W 47.4 V 39.2 V 19.34%
Solaria Corporation Solaria PowerXT-355R-BD 355.0 W 323.0 W 47.7 V 39.5 V 19.61%

How Many Solaria Corporation Solaria PowerXT-355R-BD Modules Fit in a Cold-Weather String?

Maximum series module counts for Solaria Corporation Solaria PowerXT-355R-BD from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=47.7V and beta_Voc=-0.3%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.14 V 11 panels 595.5 V 18 panels
-10 C (14 F) 52.71 V 11 panels 579.8 V 18 panels
0 C (32 F) 51.28 V 11 panels 564.1 V 19 panels
25 C (77 F STC) 47.7 V 12 panels 572.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Solaria Corporation Solaria PowerXT-355R-BD?

Alternative CEC solar modules from competing brands near Solaria Corporation Solaria PowerXT-355R-BD (355.0 W), including Bluesun Solar Energy Tech CoLtd BSM355P-72.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Bluesun Solar Energy Tech CoLtd BSM355P-72
Bluesun Solar Energy Tech CoLtd
355.0 W Tie (0 W) 47.52 V 18.32% 91.6%
AXITEC AC-355M/156-72S
AXITEC
355.0 W Tie (0 W) 47.4 V 18.3% 91.5%
Boviet Solar Technology Co Ltd BVM6612P-355
Boviet Solar Technology Co Ltd
355.0 W Tie (0 W) 47.3 V 18.3% 92.6%
CertainTeed CT355M00-01
CertainTeed
355.0 W Tie (0 W) 47.3 V 19.61% 92.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solaria Corporation Solaria PowerXT-355R-BD?

Evaluate Solaria Corporation Solaria PowerXT-355R-BD (355.0 W STC, 47.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solaria Corporation Solaria PowerXT-355R-BD reaches 54.14 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 448 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (448 sq ft).
  • 2026 tax credit baseline: cash residential installs of Solaria Corporation Solaria PowerXT-355R-BD carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solaria Corporation Solaria PowerXT-355R-BD 8 kW Residential Fit

Needs 23 modules (448 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM355P-72.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 323.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solaria Corporation Solaria PowerXT-355R-BD by Solaria Corporation grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Solaria Corporation Solaria PowerXT-355R-BD PTC wattage (323.0 W) lower than STC (355.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 323.0 W PTC (91.0% retention) across Solaria Corporation Solaria PowerXT-355R-BD's 1.81 m2 aperture.

Who should skip Solaria Corporation Solaria PowerXT-355R-BD on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 23 Solaria Corporation Solaria PowerXT-355R-BD panels (448 sq ft) leave unusable roof gaps vs. Bluesun Solar Energy Tech CoLtd BSM355P-72.

What is the 1,000 V commercial string limit for Solaria Corporation Solaria PowerXT-355R-BD?

On 1,000 V commercial inverters at -10 C (52.71 V cold Voc), Solaria Corporation Solaria PowerXT-355R-BD fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Solaria Corporation Solaria PowerXT-355R-BD.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.