Solarbine S6T AC is a 255.0 W STC (229.6 W PTC) Mono-c-Si solar module ranking #19,421 of 21,677 CEC listings (below all-CEC median; higher than 9.2% of peers). It delivers 15.33% efficiency, 37.5 V Voc at 25 C, and 42.41 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 255.0 W
- PTC Wattage
- 229.6 W
- Voc @ 25C
- 37.5 V
- Efficiency
- 15.33%
How Does Solarbine S6T AC Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Solarbine S6T AC (Mono-c-Si) residential solar systems.
Homeowners evaluating Solarbine S6T AC need 24 panels for 6 kW or 32 panels (573 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (573 sq ft). Under NEC 690.7(A), beta_Voc (-0.374%/C) pushes open-circuit voltage to 42.41 V at 14 F and 43.81 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Solarbine S6T AC Fall Across Listed CEC Models?
Comparison of Solarbine S6T AC (255.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
What Dataset Percentiles Define Solarbine S6T AC?
Relative ranking of Solarbine S6T AC across nameplate watts, 90.0% PTC thermal ratio, and module aperture efficiency. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
What Do the Dataset Ranks Show for Solarbine S6T AC?
Summary of Solarbine S6T AC output rank, 8 kW array size (32 panels), efficiency rating, and 600 V string limit.
255.0 W STC · Higher Than 9.2%
255.0 W STC (-130.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
15.33% Aperture Efficiency
Power density 153.3 W/m2 (4.58 percentage points below 19.91% CEC median). PTC/STC ratio: 90.0% (rank #18,995).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.41 V at -10 C (593.7 V string) and 43.81 V at -20 C (13 max).
32 Panels = 8,160 W STC
Occupies 53.2 m2 (573 sq ft) producing 7,347 W PTC; NEC 690.8 OCPD floor is 13.82 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 37.5 * (1 + (-0.374/100) * (-10 - 25)) = 42.41 V | OCPD = 1.56 * 8.86 = 13.82 A
Inputs from CEC Modules.csv for Solarbine S6T AC: Voc=37.5 V, beta_Voc=-0.374%/C, Isc=8.86 A, STC=255.0 W, Area=1.663 m2.
Result: 14 panels max on 600 V (593.7 V); 32 panels for 8 kW (573 sq ft).
What Are the Published CEC Specifications for Solarbine S6T AC?
Complete CEC test sheet for Solarbine S6T AC including Isc (8.86 A), Voc (37.5 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 255.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 229.6 W (90.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 37.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.86 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.65 V / 8.32 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.374 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.33% (1.663 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many Solarbine S6T AC Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Solarbine S6T AC.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 24 | 6.12 kW | 430 sq ft | $1,532 | $2,590 |
| 8 kW Class | 32 | 8.16 kW | 573 sq ft | $2,042 | $3,454 |
| 10 kW Class | 40 | 10.2 kW | 716 sq ft | $2,553 | $4,317 |
How Many Solarbine S6T AC Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Solarbine S6T AC (37.5 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.81 V | 13 panels | 569.5 V | 22 panels |
| -10 C (14 F) | 42.41 V | 14 panels | 593.7 V | 23 panels |
| 0 C (32 F) | 41.01 V | 14 panels | 574.1 V | 24 panels |
| 25 C (77 F STC) | 37.5 V | 16 panels | 600.0 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Solarbine S6T AC?
Four comparable CEC modules such as Advance Power API-P255 (255.0 W) for side-by-side solar quote checks. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Advance Power API-P255 Advance Power |
255.0 W | Tie (0 W) | 37.5 V | 15.57% | 89.4% |
| Auxin Solar AXN6P610T255 Auxin Solar |
255.0 W | Tie (0 W) | 37.5 V | 15.57% | 89.4% |
| Eoplly New Energy Technology EP156M/60-255 AC Eoplly New Energy Technology |
255.0 W | Tie (0 W) | 37.56 V | 15.76% | 89.9% |
| Eoplly New Energy Technology EP156M/60-255S AC Eoplly New Energy Technology |
255.0 W | Tie (0 W) | 37.56 V | 15.76% | 89.9% |
What Are the Design Limits and Best-Fit Uses for Solarbine S6T AC?
Evaluate Solarbine S6T AC (255.0 W STC, 37.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Solarbine S6T AC reaches 43.81 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 32 panels for an 8 kW build require 573 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 32 panels (573 sq ft).
- 2026 tax credit baseline: cash residential installs of Solarbine S6T AC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Solarbine S6T AC 8 kW Residential Fit
Needs 32 modules (573 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Advance Power API-P255.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 229.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Solarbine S6T AC by Solarbine grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Solarbine S6T AC PTC wattage (229.6 W) lower than STC (255.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 229.6 W PTC (90.0% retention) across Solarbine S6T AC's 1.663 m2 aperture.
Who should skip Solarbine S6T AC on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 32 Solarbine S6T AC panels (573 sq ft) leave unusable roof gaps vs. Advance Power API-P255.
What is the 1,000 V commercial string limit for Solarbine S6T AC?
On 1,000 V commercial inverters at -10 C (42.41 V cold Voc), Solarbine S6T AC fits up to 23 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Solarbine S6T AC.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)