Skip to main content
WireAndSun
Calculators
CEC PV Module

Solarbest Energy-Tech (Zhejiang) SE-M230(156) — CEC Solar Module Specifications

Manufacturer: Solarbest Energy-Tech (Zhejiang) Registry: CEC Verified Engineering Specification

Solarbest Energy-Tech (Zhejiang) SE-M230(156) is a 230.0 W STC (206.4 W PTC) Mono-c-Si solar module ranking #20,522 of 21,677 CEC listings (below all-CEC median; higher than 4.7% of peers). It delivers 14.05% efficiency, 36.57 V Voc at 25 C, and 42.12 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
230.0 W
PTC Wattage
206.4 W
Voc @ 25C
36.57 V
Efficiency
14.05%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Solarbest Energy-Tech (Zhejiang) SE-M230(156) Compare Against Peer CEC Listings?

How Solarbest Energy-Tech (Zhejiang) Solarbest Energy-Tech (Zhejiang) SE-M230(156) handles rooftop heat (206.4 W PTC), 8 kW sizing, and cold winter string voltage.

Solarbest Energy-Tech (Zhejiang) builds the Solarbest Energy-Tech (Zhejiang) SE-M230(156) (Mono-c-Si) as a compact residential or specialty off-grid module delivering 140.5 W/m2 (5.86 percentage points below 19.91% CEC median). Compared against Gintung Energy ASEC-230G6S (230.0 W), this model holds typical 89.7% PTC-to-STC thermal output (206.4 W real-world rating). Lower 36.57 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 13.46 A overcurrent floor served by a 15 A breaker.

Where Does Solarbest Energy-Tech (Zhejiang) SE-M230(156) Fall Across Listed CEC Models?

Where Solarbest Energy-Tech (Zhejiang) SE-M230(156) (230.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Solarbest Energy-Tech (Zhejiang) SE-M230(156) (230.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSolarbest Energy-T: 230.0 W

What Dataset Percentiles Define Solarbest Energy-Tech (Zhejiang) SE-M230(156)?

Percentile placement of Solarbest Energy-Tech (Zhejiang) SE-M230(156) across power density (140.5 W/m2), thermal retention, and nameplate STC wattage.

Solarbest Energy-Tech (Zhejiang) SE-M230(156) Engineering BenchmarksPercentile comparison of Solarbest Energy-Tech (Zhejiang) SE-M230(156) wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage230.0 WPTC/STC Retention89.7%Module Efficiency14.05%

What Do the Dataset Ranks Show for Solarbest Energy-Tech (Zhejiang) SE-M230(156)?

Four critical engineering numbers homeowners and solar installers check first when reviewing Solarbest Energy-Tech (Zhejiang) SE-M230(156) specifications.

Rank #20,522 / 21,677

230.0 W STC · Higher Than 4.7%

230.0 W STC (-155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #20,865

14.05% Aperture Efficiency

Power density 140.5 W/m2 (5.86 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 42.12 V at -10 C (589.7 V string) and 43.71 V at -20 C (13 max).

8 kW Reference Array

35 Panels = 8,050 W STC

Occupies 57.3 m2 (617 sq ft) producing 7,224 W PTC; NEC 690.8 OCPD floor is 13.46 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.57 * (1 + (-0.434/100) * (-10 - 25)) = 42.12 V | OCPD = 1.56 * 8.63 = 13.46 A

Inputs from CEC Modules.csv for Solarbest Energy-Tech (Zhejiang) SE-M230(156): Voc=36.57 V, beta_Voc=-0.434%/C, Isc=8.63 A, STC=230.0 W, Area=1.637 m2.

Result: 14 panels max on 600 V (589.7 V); 35 panels for 8 kW (617 sq ft).

What Are the Published CEC Specifications for Solarbest Energy-Tech (Zhejiang) SE-M230(156)?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Solarbest Energy-Tech (Zhejiang) SE-M230(156).

Official California Energy Commission (NREL SAM) test parameters for Solarbest Energy-Tech (Zhejiang) SE-M230(156).
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 230.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 206.4 W (89.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.57 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.63 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.08 V / 7.65 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.434 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.05% (1.637 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Solarbest Energy-Tech (Zhejiang) SE-M230(156) Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Solarbest Energy-Tech (Zhejiang) SE-M230(156) (230.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 27 6.21 kW 476 sq ft $1,554 $2,628
8 kW Class 35 8.05 kW 617 sq ft $2,015 $3,407
10 kW Class 44 10.12 kW 775 sq ft $2,533 $4,283

How Many Solarbest Energy-Tech (Zhejiang) SE-M230(156) Modules Fit in a Cold-Weather String?

Maximum series module counts for Solarbest Energy-Tech (Zhejiang) SE-M230(156) from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=36.57V and beta_Voc=-0.434%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 43.71 V 13 panels 568.2 V 22 panels
-10 C (14 F) 42.12 V 14 panels 589.7 V 23 panels
0 C (32 F) 40.54 V 14 panels 567.6 V 24 panels
25 C (77 F STC) 36.57 V 16 panels 585.1 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to Solarbest Energy-Tech (Zhejiang) SE-M230(156)?

Alternative CEC solar modules from competing brands near Solarbest Energy-Tech (Zhejiang) SE-M230(156) (230.0 W), including Gintung Energy ASEC-230G6S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Gintung Energy ASEC-230G6S
Gintung Energy
230.0 W Tie (0 W) 36.75 V 14.28% 89.7%
Grape Solar GS-P-230-CS
Grape Solar
230.0 W Tie (0 W) 36.8 V 14.3% 91.7%
Gintung Energy ASEC-230G6M
Gintung Energy
230.0 W Tie (0 W) 36.87 V 14.28% 89.4%
Anji Dasol Solar Energy Science & Technology DS-A4-230
Anji Dasol Solar Energy Science & Technology
230.0 W Tie (0 W) 36.9 V 13.97% 87.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Solarbest Energy-Tech (Zhejiang) SE-M230(156)?

Evaluate Solarbest Energy-Tech (Zhejiang) SE-M230(156) (230.0 W STC, 36.57 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Solarbest Energy-Tech (Zhejiang) SE-M230(156) reaches 43.71 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 35 panels for an 8 kW build require 617 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 35 panels (617 sq ft).
  • 2026 tax credit baseline: cash residential installs of Solarbest Energy-Tech (Zhejiang) SE-M230(156) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Solarbest Energy-Tech (Zhejiang) SE-M230(156) 8 kW Residential Fit

Needs 35 modules (617 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare Gintung Energy ASEC-230G6S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 206.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Solarbest Energy-Tech (Zhejiang) SE-M230(156) by Solarbest Energy-Tech (Zhejiang) grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Solarbest Energy-Tech (Zhejiang) SE-M230(156)?

Multiplying Solarbest Energy-Tech (Zhejiang) SE-M230(156)'s 8.63 A short-circuit current by 1.56 equals 13.46 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Solarbest Energy-Tech (Zhejiang) SE-M230(156) pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 42.12 V cold Voc at 14 F and handles 8.63 A Isc; string inverters cap Solarbest Energy-Tech (Zhejiang) SE-M230(156) at 14 panels on 600 V.

Is Solarbest Energy-Tech (Zhejiang) SE-M230(156) eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Solarbest Energy-Tech (Zhejiang) SE-M230(156) rely on utility bill offset (~$2,015/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.