SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL is a 540.0 W STC (503.0 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 21.6% efficiency, 49.72 V Voc at 25 C, and 54.78 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 540.0 W
- PTC Wattage
- 503.0 W
- Voc @ 25C
- 49.72 V
- Efficiency
- 21.6%
How Does SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL Compare Against Peer CEC Listings?
Solar engineering breakdown for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from SOLAR LONG PV-TECH(CAMBODIA)COLTD and peers, SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL stands 130.0 W above the 410.0 W Mono-c-Si median and strong 93.1% PTC-to-STC heat retention (#9,420 of 21,677). Sizing 6 kW (12 panels) to 10 kW (19 panels) yields $1,622-$2,568/yr in baseline US bill offset. Higher 49.72 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL Fall Across Listed CEC Models?
Distribution marker showing SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL (540.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL?
Dataset percentiles tracking SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL?
Benchmark highlights for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 16.3% STC Output
540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.6% Aperture Efficiency
Power density 216.0 W/m2 (1.69 percentage points above 19.91% CEC median). PTC/STC ratio: 93.1% (rank #9,420).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.78 V at -10 C (547.8 V string) and 56.23 V at -20 C (10 max).
15 Panels = 8,100 W STC
Occupies 37.5 m2 (404 sq ft) producing 7,545 W PTC; NEC 690.8 OCPD floor is 21.11 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.72 * (1 + (-0.291/100) * (-10 - 25)) = 54.78 V | OCPD = 1.56 * 13.53 = 21.11 A
Inputs from CEC Modules.csv for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL: Voc=49.72 V, beta_Voc=-0.291%/C, Isc=13.53 A, STC=540.0 W, Area=2.5 m2.
Result: 10 panels max on 600 V (547.8 V); 15 panels for 8 kW (404 sq ft).
What Are the Published CEC Specifications for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL?
Official CEC datasheet figures for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 540.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 503.0 W (93.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.72 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.53 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.05 V / 12.84 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.291 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.6% (2.5 m2) | Array roof footprint density |
| Cell Count & Technology | 48 cells (Mono-c-Si) | Bifacial glass-glass |
How Many SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.48 kW | 323 sq ft | $1,622 | $2,742 |
| 8 kW Class | 15 | 8.1 kW | 404 sq ft | $2,027 | $3,428 |
| 10 kW Class | 19 | 10.26 kW | 511 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This SOLAR LONG PV-TECH(CAMBODIA)COLTD Series?
Consolidated SOLAR LONG PV-TECH(CAMBODIA)COLTD wattage variants sharing the SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| SOLAR LONG PV-TECH(CAMBODIA)COLTD SL535MLBT-72H-VTL | 535.0 W | 498.2 W | 49.42 V | 41.83 V | 21.4% |
| SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL | 540.0 W | 503.0 W | 49.72 V | 42.05 V | 21.6% |
| SOLAR LONG PV-TECH(CAMBODIA)COLTD SL545MLBT-72H-VTL | 545.0 W | 507.8 W | 50.02 V | 42.27 V | 21.8% |
How Many SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL (54.78 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.23 V | 10 panels | 562.3 V | 17 panels |
| -10 C (14 F) | 54.78 V | 10 panels | 547.8 V | 18 panels |
| 0 C (32 F) | 53.34 V | 11 panels | 586.7 V | 18 panels |
| 25 C (77 F STC) | 49.72 V | 12 panels | 596.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL?
Competing CEC solar panels closest to SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL in nameplate wattage and Voc, starting with Convalt Manufacturing LLC CVLT540-144BMH.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Convalt Manufacturing LLC CVLT540-144BMH Convalt Manufacturing LLC |
540.0 W | Tie (0 W) | 49.65 V | 21.26% | 92.6% |
| Convalt Manufacturing LLC CVLT540-144BMH-DG Convalt Manufacturing LLC |
540.0 W | Tie (0 W) | 49.65 V | 20.93% | 93.4% |
| ASTORIOS Holding Inc ASTR144BDG-540W-US ASTORIOS Holding Inc |
540.0 W | Tie (0 W) | 49.8 V | 20.93% | 93.6% |
| Energy America LLC EA-ZLK7-SHDB144-540/M Energy America LLC |
540.0 W | Tie (0 W) | 49.8 V | 20.93% | 93.6% |
What Are the Design Limits and Best-Fit Uses for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL?
Evaluate SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL (540.0 W STC, 49.72 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL reaches 56.23 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 404 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL 8 kW Residential Fit
Needs 15 modules (404 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Convalt Manufacturing LLC CVLT540-144BMH.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 503.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL by SOLAR LONG PV-TECH(CAMBODIA)COLTD grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL?
Multiplying SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL's 13.53 A short-circuit current by 1.56 equals 21.11 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.78 V cold Voc at 14 F and handles 13.53 A Isc; string inverters cap SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL at 10 panels on 600 V.
Is SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SOLAR LONG PV-TECH(CAMBODIA)COLTD SL540MLBT-72H-VTL rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)