Skip to main content
WireAndSun
Calculators
CEC PV Module

SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL — CEC Solar Module Specifications

Manufacturer: SOLAR LONG PV-TECH(CAMBODIA)COLTD Registry: CEC Verified Engineering Specification

SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL is a 410.0 W STC (383.4 W PTC) Mono-c-Si solar module ranking #8,539 of 21,677 CEC listings (top 41.3%; higher than 58.7% of peers). It delivers 21.13% efficiency, 37.14 V Voc at 25 C, and 40.68 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
410.0 W
PTC Wattage
383.4 W
Voc @ 25C
37.14 V
Efficiency
21.13%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL Compare Against Peer CEC Listings?

How SOLAR LONG PV-TECH(CAMBODIA)COLTD SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL handles rooftop heat (383.4 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL exhibits 13.92 A short-circuit current, requiring a 21.72 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #8,539 of 21,677 (equal to the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 38.8 m2 for an 8 kW system (25 panels for 10 kW). Lower 37.14 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.

Where Does SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL Fall Across Listed CEC Models?

Where SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL (410.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL (410.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSOLAR LONG PV-TECH: 410.0 W

What Dataset Percentiles Define SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL?

Percentile placement of SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL across power density (211.3 W/m2), thermal retention, and nameplate STC wattage.

SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL Engineering BenchmarksPercentile comparison of SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage410.0 WPTC/STC Retention93.5%Module Efficiency21.13%

What Do the Dataset Ranks Show for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL?

Four critical engineering numbers homeowners and solar installers check first when reviewing SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL specifications.

Rank #8,539 / 21,677

Top 41.3% STC Output

410.0 W STC (+25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,767

21.13% Aperture Efficiency

Power density 211.3 W/m2 (1.22 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.68 V at -10 C (569.5 V string) and 41.69 V at -20 C (14 max).

8 kW Reference Array

20 Panels = 8,200 W STC

Occupies 38.8 m2 (418 sq ft) producing 7,668 W PTC; NEC 690.8 OCPD floor is 21.72 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 37.14 * (1 + (-0.272/100) * (-10 - 25)) = 40.68 V | OCPD = 1.56 * 13.92 = 21.72 A

Inputs from CEC Modules.csv for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL: Voc=37.14 V, beta_Voc=-0.272%/C, Isc=13.92 A, STC=410.0 W, Area=1.94 m2.

Result: 14 panels max on 600 V (569.5 V); 20 panels for 8 kW (418 sq ft).

What Are the Published CEC Specifications for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL.

Official California Energy Commission (NREL SAM) test parameters for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 410.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 383.4 W (93.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 37.14 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.92 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.62 V / 13.39 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.272 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.13% (1.94 m2) Array roof footprint density
Cell Count & Technology 36 cells (Mono-c-Si) Monofacial backsheet

How Many SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL (410.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.15 kW 313 sq ft $1,539 $2,603
8 kW Class 20 8.2 kW 418 sq ft $2,052 $3,470
10 kW Class 25 10.25 kW 522 sq ft $2,565 $4,338

Which Sibling Wattage & Trim Variants Belong to This SOLAR LONG PV-TECH(CAMBODIA)COLTD Series?

All closely matched SOLAR LONG PV-TECH(CAMBODIA)COLTD wattages and cosmetic trims sharing the SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL architecture.

Sibling CEC listings grouped into the SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SOLAR LONG PV-TECH(CAMBODIA)COLTD SL400ML-54H-VTL 400.0 W 373.8 W 36.98 V 30.42 V 20.62%
SOLAR LONG PV-TECH(CAMBODIA)COLTD SL405ML-54H-VTL 405.0 W 378.6 W 37.06 V 30.52 V 20.88%
SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL 410.0 W 383.4 W 37.14 V 30.62 V 21.13%
SOLAR LONG PV-TECH(CAMBODIA)COLTD SL415ML-54H-VTL 415.0 W 388.2 W 37.31 V 30.79 V 21.39%

How Many SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL Modules Fit in a Cold-Weather String?

Maximum series module counts for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=37.14V and beta_Voc=-0.272%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.69 V 14 panels 583.7 V 23 panels
-10 C (14 F) 40.68 V 14 panels 569.5 V 24 panels
0 C (32 F) 39.67 V 15 panels 595.1 V 25 panels
25 C (77 F STC) 37.14 V 16 panels 594.2 V 26 panels

Which Cross-Brand Solar Modules Compare Closest to SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL?

Alternative CEC solar modules from competing brands near SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL (410.0 W), including BYD Company Limited BYD410MLK-27.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
BYD Company Limited BYD410MLK-27
BYD Company Limited
410.0 W Tie (0 W) 37.14 V 21.13% 92.7%
CSI Solar Co Ltd CS6R-410MS-HL {Wht}
CSI Solar Co Ltd
410.0 W Tie (0 W) 37.2 V 21.03% 94.2%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE410MD-108
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
410.0 W Tie (0 W) 37.23 V 21.24% 92.7%
Dehui Solar Power (Vietnam) CoLtd DH-M154W 410W
Dehui Solar Power (Vietnam) CoLtd
410.0 W Tie (0 W) 37.23 V 21.24% 92.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL?

Evaluate SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL (410.0 W STC, 37.14 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL reaches 41.69 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 418 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (418 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL 8 kW Residential Fit

Needs 20 modules (418 sq ft) with a 25 A string OCPD, offsetting ~$2,052/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare BYD Company Limited BYD410MLK-27.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 383.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL by SOLAR LONG PV-TECH(CAMBODIA)COLTD grounded in CEC test data and NEC 690.7/690.8 limits.

Why is SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL PTC wattage (383.4 W) lower than STC (410.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 383.4 W PTC (93.5% retention) across SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL's 1.94 m2 aperture.

Who should skip SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 20 SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL panels (418 sq ft) leave unusable roof gaps vs. BYD Company Limited BYD410MLK-27.

What is the 1,000 V commercial string limit for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL?

On 1,000 V commercial inverters at -10 C (40.68 V cold Voc), SOLAR LONG PV-TECH(CAMBODIA)COLTD SL410ML-54H-VTL fits up to 24 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.