SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL is a 395.0 W STC (369.0 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.36% efficiency, 36.9 V Voc at 25 C, and 40.41 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 395.0 W
- PTC Wattage
- 369.0 W
- Voc @ 25C
- 36.9 V
- Efficiency
- 20.36%
How Does SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL Compare Against Peer CEC Listings?
How SOLAR LONG PV-TECH(CAMBODIA)COLTD SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL handles rooftop heat (369.0 W PTC), 8 kW sizing, and cold winter string voltage.
SOLAR LONG PV-TECH(CAMBODIA)COLTD builds the SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 203.6 W/m2 (0.45 percentage points above 19.91% CEC median). Compared against BYD Company Limited BYD395MLK-27 (395.0 W), this model holds strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Lower 36.9 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.39 A overcurrent floor served by a 25 A breaker.
Where Does SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL Fall Across Listed CEC Models?
Where SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?
Percentile placement of SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL across power density (203.6 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?
Four critical engineering numbers homeowners and solar installers check first when reviewing SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL specifications.
Top 47.6% STC Output
395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.36% Aperture Efficiency
Power density 203.6 W/m2 (0.45 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 40.41 V at -10 C (565.7 V string) and 41.42 V at -20 C (14 max).
21 Panels = 8,295 W STC
Occupies 40.7 m2 (439 sq ft) producing 7,749 W PTC; NEC 690.8 OCPD floor is 21.39 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 36.9 * (1 + (-0.272/100) * (-10 - 25)) = 40.41 V | OCPD = 1.56 * 13.71 = 21.39 A
Inputs from CEC Modules.csv for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL: Voc=36.9 V, beta_Voc=-0.272%/C, Isc=13.71 A, STC=395.0 W, Area=1.94 m2.
Result: 14 panels max on 600 V (565.7 V); 21 panels for 8 kW (439 sq ft).
What Are the Published CEC Specifications for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 395.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 369.0 W (93.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 36.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.71 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 30.32 V / 13.03 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.272 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.36% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 36 cells (Mono-c-Si) | Monofacial backsheet |
How Many SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL (395.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.32 kW | 334 sq ft | $1,582 | $2,675 |
| 8 kW Class | 21 | 8.29 kW | 439 sq ft | $2,075 | $3,509 |
| 10 kW Class | 26 | 10.27 kW | 543 sq ft | $2,570 | $4,347 |
How Many SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL Modules Fit in a Cold-Weather String?
Maximum series module counts for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 41.42 V | 14 panels | 579.9 V | 24 panels |
| -10 C (14 F) | 40.41 V | 14 panels | 565.7 V | 24 panels |
| 0 C (32 F) | 39.41 V | 15 panels | 591.1 V | 25 panels |
| 25 C (77 F STC) | 36.9 V | 16 panels | 590.4 V | 27 panels |
Which Cross-Brand Solar Modules Compare Closest to SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?
Alternative CEC solar modules from competing brands near SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL (395.0 W), including BYD Company Limited BYD395MLK-27.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| BYD Company Limited BYD395MLK-27 BYD Company Limited |
395.0 W | Tie (0 W) | 36.9 V | 20.36% | 92.6% |
| Energate Energy Inc EG-108L395W Energate Energy Inc |
395.0 W | Tie (0 W) | 36.9 V | 20.36% | 93.6% |
| Energate Enerji retim San A EG-108L395W Energate Enerji retim San A |
395.0 W | Tie (0 W) | 36.9 V | 20.36% | 93.6% |
| ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108 ALTERNATIVE ENERGY (AE) SOLAR CO LTD |
395.0 W | Tie (0 W) | 36.94 V | 20.47% | 92.6% |
What Are the Design Limits and Best-Fit Uses for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?
Evaluate SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL (395.0 W STC, 36.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL reaches 41.42 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 21 panels for an 8 kW build require 439 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (439 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL 8 kW Residential Fit
Needs 21 modules (439 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare BYD Company Limited BYD395MLK-27.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 369.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL by SOLAR LONG PV-TECH(CAMBODIA)COLTD grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?
Multiplying SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL's 13.71 A short-circuit current by 1.56 equals 21.39 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 40.41 V cold Voc at 14 F and handles 13.71 A Isc; string inverters cap SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL at 14 panels on 600 V.
Is SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)