Skip to main content
WireAndSun
Calculators
CEC PV Module

SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL — CEC Solar Module Specifications

Manufacturer: SOLAR LONG PV-TECH(CAMBODIA)COLTD Registry: CEC Verified Engineering Specification

SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL is a 395.0 W STC (369.0 W PTC) Mono-c-Si solar module ranking #9,869 of 21,677 CEC listings (top 47.6%; higher than 52.4% of peers). It delivers 20.36% efficiency, 36.9 V Voc at 25 C, and 40.41 V cold Voc at -10 C (14 panels max per 600 V string).

STC Wattage
395.0 W
PTC Wattage
369.0 W
Voc @ 25C
36.9 V
Efficiency
20.36%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL Compare Against Peer CEC Listings?

How SOLAR LONG PV-TECH(CAMBODIA)COLTD SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL handles rooftop heat (369.0 W PTC), 8 kW sizing, and cold winter string voltage.

SOLAR LONG PV-TECH(CAMBODIA)COLTD builds the SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 203.6 W/m2 (0.45 percentage points above 19.91% CEC median). Compared against BYD Company Limited BYD395MLK-27 (395.0 W), this model holds strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Lower 36.9 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 21.39 A overcurrent floor served by a 25 A breaker.

Where Does SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL Fall Across Listed CEC Models?

Where SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL (395.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL (395.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSOLAR LONG PV-TECH: 395.0 W

What Dataset Percentiles Define SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?

Percentile placement of SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL across power density (203.6 W/m2), thermal retention, and nameplate STC wattage.

SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL Engineering BenchmarksPercentile comparison of SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage395.0 WPTC/STC Retention93.4%Module Efficiency20.36%

What Do the Dataset Ranks Show for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?

Four critical engineering numbers homeowners and solar installers check first when reviewing SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL specifications.

Rank #9,869 / 21,677

Top 47.6% STC Output

395.0 W STC (+10.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,064

20.36% Aperture Efficiency

Power density 203.6 W/m2 (0.45 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

14 Panels Max @ -10 C (600 V)

Cold Voc reaches 40.41 V at -10 C (565.7 V string) and 41.42 V at -20 C (14 max).

8 kW Reference Array

21 Panels = 8,295 W STC

Occupies 40.7 m2 (439 sq ft) producing 7,749 W PTC; NEC 690.8 OCPD floor is 21.39 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 36.9 * (1 + (-0.272/100) * (-10 - 25)) = 40.41 V | OCPD = 1.56 * 13.71 = 21.39 A

Inputs from CEC Modules.csv for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL: Voc=36.9 V, beta_Voc=-0.272%/C, Isc=13.71 A, STC=395.0 W, Area=1.94 m2.

Result: 14 panels max on 600 V (565.7 V); 21 panels for 8 kW (439 sq ft).

What Are the Published CEC Specifications for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL.

Official California Energy Commission (NREL SAM) test parameters for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 395.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 369.0 W (93.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 36.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.71 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 30.32 V / 13.03 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.272 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.36% (1.94 m2) Array roof footprint density
Cell Count & Technology 36 cells (Mono-c-Si) Monofacial backsheet

How Many SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL (395.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 16 6.32 kW 334 sq ft $1,582 $2,675
8 kW Class 21 8.29 kW 439 sq ft $2,075 $3,509
10 kW Class 26 10.27 kW 543 sq ft $2,570 $4,347

How Many SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL Modules Fit in a Cold-Weather String?

Maximum series module counts for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=36.9V and beta_Voc=-0.272%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 41.42 V 14 panels 579.9 V 24 panels
-10 C (14 F) 40.41 V 14 panels 565.7 V 24 panels
0 C (32 F) 39.41 V 15 panels 591.1 V 25 panels
25 C (77 F STC) 36.9 V 16 panels 590.4 V 27 panels

Which Cross-Brand Solar Modules Compare Closest to SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?

Alternative CEC solar modules from competing brands near SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL (395.0 W), including BYD Company Limited BYD395MLK-27.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
BYD Company Limited BYD395MLK-27
BYD Company Limited
395.0 W Tie (0 W) 36.9 V 20.36% 92.6%
Energate Energy Inc EG-108L395W
Energate Energy Inc
395.0 W Tie (0 W) 36.9 V 20.36% 93.6%
Energate Enerji retim San A EG-108L395W
Energate Enerji retim San A
395.0 W Tie (0 W) 36.9 V 20.36% 93.6%
ALTERNATIVE ENERGY (AE) SOLAR CO LTD AE395MD-108
ALTERNATIVE ENERGY (AE) SOLAR CO LTD
395.0 W Tie (0 W) 36.94 V 20.47% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?

Evaluate SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL (395.0 W STC, 36.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL reaches 41.42 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 21 panels for an 8 kW build require 439 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 21 panels (439 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL 8 kW Residential Fit

Needs 21 modules (439 sq ft) with a 25 A string OCPD, offsetting ~$2,075/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare BYD Company Limited BYD395MLK-27.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 369.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL by SOLAR LONG PV-TECH(CAMBODIA)COLTD grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL?

Multiplying SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL's 13.71 A short-circuit current by 1.56 equals 21.39 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.

Can SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 40.41 V cold Voc at 14 F and handles 13.71 A Isc; string inverters cap SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL at 14 panels on 600 V.

Is SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SOLAR LONG PV-TECH(CAMBODIA)COLTD SL395ML-54H-VTL rely on utility bill offset (~$2,075/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.