Silfab Solar Inc SIL380MT is a 380.0 W STC (349.7 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 20.0% efficiency, 48.4 V Voc at 25 C, and 53.16 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 380.0 W
- PTC Wattage
- 349.7 W
- Voc @ 25C
- 48.4 V
- Efficiency
- 20.0%
How Does Silfab Solar Inc SIL380MT Compare Against Peer CEC Listings?
Solar engineering breakdown for Silfab Solar Inc SIL380MT: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Silfab Solar Inc and peers, Silfab Solar Inc SIL380MT stands 30.0 W below the 410.0 W Mono-c-Si median and strong 92.0% PTC-to-STC heat retention (#14,141 of 21,677). Sizing 6 kW (16 panels) to 10 kW (27 panels) yields $1,522-$2,568/yr in baseline US bill offset. Higher 48.4 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Silfab Solar Inc SIL380MT Fall Across Listed CEC Models?
Distribution marker showing Silfab Solar Inc SIL380MT (380.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Silfab Solar Inc SIL380MT?
Dataset percentiles tracking Silfab Solar Inc SIL380MT power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Silfab Solar Inc SIL380MT?
Benchmark highlights for Silfab Solar Inc SIL380MT covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
380.0 W STC · Higher Than 47.6%
380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.0% Aperture Efficiency
Power density 200.0 W/m2 (0.09 percentage points above 19.91% CEC median). PTC/STC ratio: 92.0% (rank #14,141).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.16 V at -10 C (584.8 V string) and 54.52 V at -20 C (11 max).
22 Panels = 8,360 W STC
Occupies 41.8 m2 (450 sq ft) producing 7,693 W PTC; NEC 690.8 OCPD floor is 15.57 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.4 * (1 + (-0.281/100) * (-10 - 25)) = 53.16 V | OCPD = 1.56 * 9.98 = 15.57 A
Inputs from CEC Modules.csv for Silfab Solar Inc SIL380MT: Voc=48.4 V, beta_Voc=-0.281%/C, Isc=9.98 A, STC=380.0 W, Area=1.9 m2.
Result: 11 panels max on 600 V (584.8 V); 22 panels for 8 kW (450 sq ft).
What Are the Published CEC Specifications for Silfab Solar Inc SIL380MT?
Official CEC datasheet figures for Silfab Solar Inc SIL380MT (Mono-c-Si) used in utility interconnection and permit reviews. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 349.7 W (92.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.98 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.9 V / 9.54 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.281 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.0% (1.9 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Silfab Solar Inc SIL380MT Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Silfab Solar Inc SIL380MT modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.08 kW | 327 sq ft | $1,522 | $2,573 |
| 8 kW Class | 22 | 8.36 kW | 450 sq ft | $2,092 | $3,538 |
| 10 kW Class | 27 | 10.26 kW | 552 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Silfab Solar Inc Series?
Consolidated Silfab Solar Inc wattage variants sharing the Silfab Solar Inc SIL380MT mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Silfab Solar Inc SIL375MT | 375.0 W | 344.9 W | 48.3 V | 39.75 V | 19.74% |
| Silfab Solar Inc SIL380MT | 380.0 W | 349.7 W | 48.4 V | 39.9 V | 20.0% |
How Many Silfab Solar Inc SIL380MT Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Silfab Solar Inc SIL380MT (53.16 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.52 V | 11 panels | 599.7 V | 18 panels |
| -10 C (14 F) | 53.16 V | 11 panels | 584.8 V | 18 panels |
| 0 C (32 F) | 51.8 V | 11 panels | 569.8 V | 19 panels |
| 25 C (77 F STC) | 48.4 V | 12 panels | 580.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Silfab Solar Inc SIL380MT?
Competing CEC solar panels closest to Silfab Solar Inc SIL380MT in nameplate wattage and Voc, starting with Bluesun Solar Energy Tech CoLtd BSM380M-72.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Bluesun Solar Energy Tech CoLtd BSM380M-72 Bluesun Solar Energy Tech CoLtd |
380.0 W | Tie (0 W) | 48.67 V | 19.59% | 92.0% |
| Auxin Solar AXN6M612T380 Auxin Solar |
380.0 W | Tie (0 W) | 47.94 V | 19.58% | 91.9% |
| CertainTeed CT380M10-02 CertainTeed |
380.0 W | Tie (0 W) | 47.94 V | 20.19% | 92.0% |
| Caterpillar Inc PVC380MP03H Caterpillar Inc |
380.0 W | Tie (0 W) | 49.0 V | 19.63% | 94.1% |
What Are the Design Limits and Best-Fit Uses for Silfab Solar Inc SIL380MT?
Evaluate Silfab Solar Inc SIL380MT (380.0 W STC, 48.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Silfab Solar Inc SIL380MT reaches 54.52 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 450 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (450 sq ft).
- 2026 tax credit baseline: cash residential installs of Silfab Solar Inc SIL380MT carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Silfab Solar Inc SIL380MT 8 kW Residential Fit
Needs 22 modules (450 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Bluesun Solar Energy Tech CoLtd BSM380M-72.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 349.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Silfab Solar Inc SIL380MT by Silfab Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Silfab Solar Inc SIL380MT?
Multiplying Silfab Solar Inc SIL380MT's 9.98 A short-circuit current by 1.56 equals 15.57 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Silfab Solar Inc SIL380MT pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.16 V cold Voc at 14 F and handles 9.98 A Isc; string inverters cap Silfab Solar Inc SIL380MT at 11 panels on 600 V.
Is Silfab Solar Inc SIL380MT eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Silfab Solar Inc SIL380MT rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)