Silfab Solar Inc SIL300BL is a 300.0 W STC (267.9 W PTC) Mono-c-Si solar module ranking #16,498 of 21,677 CEC listings (below all-CEC median; higher than 22.1% of peers). It delivers 18.02% efficiency, 38.69 V Voc at 25 C, and 42.51 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 300.0 W
- PTC Wattage
- 267.9 W
- Voc @ 25C
- 38.69 V
- Efficiency
- 18.02%
How Does Silfab Solar Inc SIL300BL Compare Against Peer CEC Listings?
Engineering position of Silfab Solar Inc SIL300BL (300.0 W STC) vs. CertainTeed CT300M10-01 across 5,889 CEC Mono-c-Si solar modules.
Built with 21 Mono-c-Si cells, Silfab Solar Inc SIL300BL pairs typical 89.3% PTC-to-STC thermal output (267.9 W real-world rating) with 38.69 V nominal Voc. An 8 kW residential build (8,100 W DC, 7,233 W PTC) saves ~$2,027/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CertainTeed CT300M10-01 offers a 300.0 W alternative.
Where Does Silfab Solar Inc SIL300BL Fall Across Listed CEC Models?
Plots Silfab Solar Inc SIL300BL at 300.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Silfab Solar Inc SIL300BL?
Benchmarks Silfab Solar Inc SIL300BL on STC wattage, thermal PTC/STC retention, and 18.02 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Silfab Solar Inc SIL300BL?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Silfab Solar Inc SIL300BL by Silfab Solar Inc.
300.0 W STC · Higher Than 22.1%
300.0 W STC (-85.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.02% Aperture Efficiency
Power density 180.2 W/m2 (1.89 percentage points below 19.91% CEC median). PTC/STC ratio: 89.3% (rank #20,205).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 42.51 V at -10 C (595.1 V string) and 43.6 V at -20 C (13 max).
27 Panels = 8,100 W STC
Occupies 45.0 m2 (484 sq ft) producing 7,233 W PTC; NEC 690.8 OCPD floor is 15.3 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.69 * (1 + (-0.282/100) * (-10 - 25)) = 42.51 V | OCPD = 1.56 * 9.81 = 15.3 A
Inputs from CEC Modules.csv for Silfab Solar Inc SIL300BL: Voc=38.69 V, beta_Voc=-0.282%/C, Isc=9.81 A, STC=300.0 W, Area=1.665 m2.
Result: 14 panels max on 600 V (595.1 V); 27 panels for 8 kW (484 sq ft).
What Are the Published CEC Specifications for Silfab Solar Inc SIL300BL?
Laboratory test ratings recorded for Silfab Solar Inc SIL300BL (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 300.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 267.9 W (89.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.69 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.81 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.99 V / 9.08 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.282 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.02% (1.665 m2) | Array roof footprint density |
| Cell Count & Technology | 21 cells (Mono-c-Si) | Monofacial backsheet |
How Many Silfab Solar Inc SIL300BL Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (484 sq ft at 8 kW), and estimated Year-1 electric bill offset for Silfab Solar Inc SIL300BL.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.0 kW | 358 sq ft | $1,502 | $2,539 |
| 8 kW Class | 27 | 8.1 kW | 484 sq ft | $2,027 | $3,428 |
| 10 kW Class | 34 | 10.2 kW | 609 sq ft | $2,553 | $4,317 |
How Many Silfab Solar Inc SIL300BL Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Silfab Solar Inc SIL300BL (beta_Voc -0.282%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 43.6 V | 13 panels | 566.8 V | 22 panels |
| -10 C (14 F) | 42.51 V | 14 panels | 595.1 V | 23 panels |
| 0 C (32 F) | 41.42 V | 14 panels | 579.9 V | 24 panels |
| 25 C (77 F STC) | 38.69 V | 15 panels | 580.3 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to Silfab Solar Inc SIL300BL?
Closest cross-brand CEC competitors to Silfab Solar Inc SIL300BL matched near 300.0 W STC and 38.69 V Voc, led by CertainTeed CT300M10-01.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CertainTeed CT300M10-01 CertainTeed |
300.0 W | Tie (0 W) | 39.1 V | 18.33% | 91.0% |
| CertainTeed CT300M11-01 CertainTeed |
300.0 W | Tie (0 W) | 39.1 V | 18.33% | 90.1% |
| FreeVolt PV-GRAF-60M6-300/M FreeVolt |
300.0 W | Tie (0 W) | 39.6 V | 18.29% | 91.1% |
| Enphase Energy Inc XACM-IQ7-LR6-60PB-300M Enphase Energy Inc |
300.0 W | Tie (0 W) | 40.1 V | 18.99% | 91.1% |
What Are the Design Limits and Best-Fit Uses for Silfab Solar Inc SIL300BL?
Evaluate Silfab Solar Inc SIL300BL (300.0 W STC, 38.69 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Silfab Solar Inc SIL300BL reaches 43.6 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 27 panels for an 8 kW build require 484 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (484 sq ft).
- 2026 tax credit baseline: cash residential installs of Silfab Solar Inc SIL300BL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Silfab Solar Inc SIL300BL 8 kW Residential Fit
Needs 27 modules (484 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 13 panels (-20 C), or compare CertainTeed CT300M10-01.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 267.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Silfab Solar Inc SIL300BL by Silfab Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Silfab Solar Inc SIL300BL?
Multiplying Silfab Solar Inc SIL300BL's 9.81 A short-circuit current by 1.56 equals 15.3 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can Silfab Solar Inc SIL300BL pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 42.51 V cold Voc at 14 F and handles 9.81 A Isc; string inverters cap Silfab Solar Inc SIL300BL at 14 panels on 600 V.
Is Silfab Solar Inc SIL300BL eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Silfab Solar Inc SIL300BL rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)