Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 is a 585.0 W STC (550.8 W PTC) Mono-c-Si solar module ranking #1,751 of 21,677 CEC listings (top 8.7%; higher than 91.3% of peers). It delivers 22.67% efficiency, 51.5 V Voc at 25 C, and 55.74 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 585.0 W
- PTC Wattage
- 550.8 W
- Voc @ 25C
- 51.5 V
- Efficiency
- 22.67%
How Does Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 (Mono-c-Si) residential solar systems.
Homeowners evaluating Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 need 11 panels for 6 kW or 14 panels (389 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.235%/C) pushes open-circuit voltage to 55.74 V at 14 F and 56.95 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.
Where Does Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 Fall Across Listed CEC Models?
Comparison of Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 (585.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585?
Relative ranking of Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 across nameplate watts, 94.2% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585?
Summary of Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.
Top 8.7% STC Output
585.0 W STC (+200.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.67% Aperture Efficiency
Power density 226.7 W/m2 (2.76 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 55.74 V at -10 C (557.4 V string) and 56.95 V at -20 C (10 max).
14 Panels = 8,190 W STC
Occupies 36.1 m2 (389 sq ft) producing 7,711 W PTC; NEC 690.8 OCPD floor is 22.57 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 51.5 * (1 + (-0.235/100) * (-10 - 25)) = 55.74 V | OCPD = 1.56 * 14.47 = 22.57 A
Inputs from CEC Modules.csv for Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585: Voc=51.5 V, beta_Voc=-0.235%/C, Isc=14.47 A, STC=585.0 W, Area=2.58 m2.
Result: 10 panels max on 600 V (557.4 V); 14 panels for 8 kW (389 sq ft).
What Are the Published CEC Specifications for Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585?
Complete CEC test sheet for Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 including Isc (14.47 A), Voc (51.5 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 585.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 550.8 W (94.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 51.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.47 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 43.3 V / 13.53 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.235 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.67% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.43 kW | 305 sq ft | $1,609 | $2,721 |
| 8 kW Class | 14 | 8.19 kW | 389 sq ft | $2,050 | $3,466 |
| 10 kW Class | 18 | 10.53 kW | 500 sq ft | $2,636 | $4,457 |
Which Sibling Wattage & Trim Variants Belong to This Shanghai Aerospace Automobile Electromechanical Co Ltd Series?
Related Shanghai Aerospace Automobile Electromechanical Co Ltd power steps and black/silver trims consolidated into this Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-575 | 575.0 W | 541.1 W | 51.1 V | 42.9 V | 22.29% |
| Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-580 | 580.0 W | 546.0 W | 51.3 V | 43.1 V | 22.48% |
| Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 | 585.0 W | 550.8 W | 51.5 V | 43.3 V | 22.67% |
| Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-590 | 590.0 W | 555.6 W | 51.7 V | 43.5 V | 22.87% |
| Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-595 | 595.0 W | 560.5 W | 51.85 V | 43.55 V | 23.06% |
How Many Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 (51.5 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.95 V | 10 panels | 569.5 V | 17 panels |
| -10 C (14 F) | 55.74 V | 10 panels | 557.4 V | 17 panels |
| 0 C (32 F) | 54.53 V | 11 panels | 599.8 V | 18 panels |
| 25 C (77 F STC) | 51.5 V | 11 panels | 566.5 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585?
Four comparable CEC modules such as CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-585 (585.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-585 CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI |
585.0 W | Tie (0 W) | 51.5 V | 22.85% | 94.2% |
| Chint New Energy Technology Co Ltd CHSM72N(DG)/F-BH-585 Chint New Energy Technology Co Ltd |
585.0 W | Tie (0 W) | 51.5 V | 22.67% | 94.7% |
| Gautam Solar Pvt Ltd G2G1755-HAD Gautam Solar Pvt Ltd |
585.0 W | Tie (0 W) | 51.19 V | 22.79% | 95.1% |
| Gautam Solar Pvt Ltd G2X1755N-UHAD Gautam Solar Pvt Ltd |
585.0 W | Tie (0 W) | 51.19 V | 22.76% | 94.9% |
What Are the Design Limits and Best-Fit Uses for Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585?
Evaluate Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 (585.0 W STC, 51.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 reaches 56.95 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 389 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 8 kW Residential Fit
Needs 14 modules (389 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-585.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 550.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 by Shanghai Aerospace Automobile Electromechanical Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 PTC wattage (550.8 W) lower than STC (585.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 550.8 W PTC (94.2% retention) across Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585's 2.58 m2 aperture.
Who should skip Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 panels (389 sq ft) leave unusable roof gaps vs. CHEN GUNES ENERJISI SANAYI VE TICARET LIMITED SIRKETI FE72-18X(ND)-585.
What is the 1,000 V commercial string limit for Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585?
On 1,000 V commercial inverters at -10 C (55.74 V cold Voc), Shanghai Aerospace Automobile Electromechanical Co Ltd HT72-18X(ND)-F-585 fits up to 17 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)