Skip to main content
WireAndSun
Calculators
CEC PV Module

Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 — CEC Solar Module Specifications

Manufacturer: Shanghai Aerospace Automobile Electromechanical Co Ltd Registry: CEC Verified Engineering Specification

Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 is a 645.0 W STC (607.1 W PTC) Mono-c-Si solar module ranking #571 of 21,677 CEC listings (top 2.9%; higher than 97.1% of peers). It delivers 21.01% efficiency, 44.8 V Voc at 25 C, and 48.52 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
645.0 W
PTC Wattage
607.1 W
Voc @ 25C
44.8 V
Efficiency
21.01%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 (Mono-c-Si) residential solar systems.

Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 delivers 210.1 W/m2 (1.10 percentage points above 19.91% CEC median) and strong 94.1% PTC-to-STC heat retention (#4,203 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 49.58 V per unit, capping 600 V circuits at 12 panels. Compare specs directly with LIGHT ENGINE ILUMINACAO SA HS66-F-645-MN (645.0 W).

Where Does Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 Fall Across Listed CEC Models?

Comparison of Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 (645.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 (645.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCShanghai Aerospace: 645.0 W

What Dataset Percentiles Define Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645?

Relative ranking of Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 across nameplate watts, 94.1% PTC thermal ratio, and module aperture efficiency.

Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 Engineering BenchmarksPercentile comparison of Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage645.0 WPTC/STC Retention94.1%Module Efficiency21.01%

What Do the Dataset Ranks Show for Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645?

Summary of Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 output rank, 8 kW array size (13 panels), efficiency rating, and 600 V string limit.

Rank #571 / 21,677

Top 2.9% STC Output

645.0 W STC (+260.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,421

21.01% Aperture Efficiency

Power density 210.1 W/m2 (1.10 percentage points above 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 48.52 V at -10 C (582.2 V string) and 49.58 V at -20 C (12 max).

8 kW Reference Array

13 Panels = 8,385 W STC

Occupies 39.9 m2 (430 sq ft) producing 7,892 W PTC; NEC 690.8 OCPD floor is 28.63 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.8 * (1 + (-0.237/100) * (-10 - 25)) = 48.52 V | OCPD = 1.56 * 18.35 = 28.63 A

Inputs from CEC Modules.csv for Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645: Voc=44.8 V, beta_Voc=-0.237%/C, Isc=18.35 A, STC=645.0 W, Area=3.07 m2.

Result: 12 panels max on 600 V (582.2 V); 13 panels for 8 kW (430 sq ft).

What Are the Published CEC Specifications for Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645?

Complete CEC test sheet for Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 including Isc (18.35 A), Voc (44.8 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 645.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 607.1 W (94.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 18.35 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.7 V / 17.11 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.237 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.01% (3.07 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Bifacial glass-glass

How Many Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 10 6.45 kW 330 sq ft $1,614 $2,730
8 kW Class 13 8.38 kW 430 sq ft $2,097 $3,547
10 kW Class 16 10.32 kW 529 sq ft $2,583 $4,368

How Many Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 (44.8 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=44.8V and beta_Voc=-0.237%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 49.58 V 12 panels 595.0 V 20 panels
-10 C (14 F) 48.52 V 12 panels 582.2 V 20 panels
0 C (32 F) 47.45 V 12 panels 569.4 V 21 panels
25 C (77 F STC) 44.8 V 13 panels 582.4 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645?

Four comparable CEC modules such as LIGHT ENGINE ILUMINACAO SA HS66-F-645-MN (645.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
LIGHT ENGINE ILUMINACAO SA HS66-F-645-MN
LIGHT ENGINE ILUMINACAO SA
645.0 W Tie (0 W) 44.8 V 21.01% 94.1%
CSI Solar Co Ltd CS7N-640MB-AG
CSI Solar Co Ltd
640.0 W -5.0 W 44.6 V 20.85% 93.1%
Hanersun Energy Co Ltd HN21-66HT640W
Hanersun Energy Co Ltd
640.0 W -5.0 W 44.6 V 21.12% 94.4%
Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-640
Chint New Energy Technology Co Ltd
640.0 W -5.0 W 45.09 V 21.12% 92.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645?

Evaluate Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 (645.0 W STC, 44.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 reaches 49.58 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 13 panels for an 8 kW build require 430 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 8 kW Residential Fit

Needs 13 modules (430 sq ft) with a 30 A string OCPD, offsetting ~$2,097/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare LIGHT ENGINE ILUMINACAO SA HS66-F-645-MN.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 607.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 by Shanghai Aerospace Automobile Electromechanical Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

How many Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 panels fit on a 600 V winter solar string?

At -10 C (14 F), Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 cold Voc rises from 44.8 V to 48.52 V (beta_Voc -0.237%/C), capping a 600 V string at 12 panels (582.2 V).

How much roof area does an 8 kW array of Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 need?

An 8 kW DC system uses 13 Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 modules (8,385 W STC / 7,892 W PTC), covering roughly 430 sq ft and saving ~$2,097/yr at 18.54 c/kWh.

How does Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 compare against LIGHT ENGINE ILUMINACAO SA HS66-F-645-MN?

Shanghai Aerospace Automobile Electromechanical Co Ltd HT66-210(PD)-F-645 outputs 645.0 W STC (44.8 V Voc, rank #571 of 21,677), while LIGHT ENGINE ILUMINACAO SA HS66-F-645-MN delivers 645.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.