Skip to main content
WireAndSun
Calculators
CEC PV Module

SEG Solar Inc SEG-BMB-305WW — CEC Solar Module Specifications

Manufacturer: SEG Solar Inc Registry: CEC Verified Engineering Specification

SEG Solar Inc SEG-BMB-305WW is a 305.0 W STC (279.4 W PTC) Mono-c-Si solar module ranking #16,131 of 21,677 CEC listings (below all-CEC median; higher than 23.9% of peers). It delivers 18.63% efficiency, 39.5 V Voc at 25 C, and 43.59 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
305.0 W
PTC Wattage
279.4 W
Voc @ 25C
39.5 V
Efficiency
18.63%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does SEG Solar Inc SEG-BMB-305WW Compare Against Peer CEC Listings?

How SEG Solar Inc SEG Solar Inc SEG-BMB-305WW handles rooftop heat (279.4 W PTC), 8 kW sizing, and cold winter string voltage.

SEG Solar Inc builds the SEG Solar Inc SEG-BMB-305WW (Mono-c-Si) as a compact residential or specialty off-grid module delivering 186.3 W/m2 (1.28 percentage points below 19.91% CEC median). Compared against AXITEC AC-305M/60S (305.0 W), this model holds strong 91.6% PTC-to-STC heat retention (#15,328 of 21,677). Lower 39.5 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters, while NEC 690.8 sets a 15.12 A overcurrent floor served by a 20 A breaker.

Where Does SEG Solar Inc SEG-BMB-305WW Fall Across Listed CEC Models?

Where SEG Solar Inc SEG-BMB-305WW (305.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where SEG Solar Inc SEG-BMB-305WW (305.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCSEG Solar Inc SEG-: 305.0 W

What Dataset Percentiles Define SEG Solar Inc SEG-BMB-305WW?

Percentile placement of SEG Solar Inc SEG-BMB-305WW across power density (186.3 W/m2), thermal retention, and nameplate STC wattage.

SEG Solar Inc SEG-BMB-305WW Engineering BenchmarksPercentile comparison of SEG Solar Inc SEG-BMB-305WW wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage305.0 WPTC/STC Retention91.6%Module Efficiency18.63%

What Do the Dataset Ranks Show for SEG Solar Inc SEG-BMB-305WW?

Four critical engineering numbers homeowners and solar installers check first when reviewing SEG Solar Inc SEG-BMB-305WW specifications. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Rank #16,131 / 21,677

305.0 W STC · Higher Than 23.9%

305.0 W STC (-80.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,148

18.63% Aperture Efficiency

Power density 186.3 W/m2 (1.28 percentage points below 19.91% CEC median). PTC/STC ratio: 91.6% (rank #15,328).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.59 V at -10 C (566.7 V string) and 44.76 V at -20 C (13 max).

8 kW Reference Array

27 Panels = 8,235 W STC

Occupies 44.2 m2 (476 sq ft) producing 7,544 W PTC; NEC 690.8 OCPD floor is 15.12 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 39.5 * (1 + (-0.296/100) * (-10 - 25)) = 43.59 V | OCPD = 1.56 * 9.69 = 15.12 A

Inputs from CEC Modules.csv for SEG Solar Inc SEG-BMB-305WW: Voc=39.5 V, beta_Voc=-0.296%/C, Isc=9.69 A, STC=305.0 W, Area=1.637 m2.

Result: 13 panels max on 600 V (566.7 V); 27 panels for 8 kW (476 sq ft).

What Are the Published CEC Specifications for SEG Solar Inc SEG-BMB-305WW?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for SEG Solar Inc SEG-BMB-305WW.

Official California Energy Commission (NREL SAM) test parameters for SEG Solar Inc SEG-BMB-305WW.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 305.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 279.4 W (91.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 39.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.69 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.2 V / 9.19 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.296 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.63% (1.637 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many SEG Solar Inc SEG-BMB-305WW Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using SEG Solar Inc SEG-BMB-305WW (305.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.1 kW 352 sq ft $1,527 $2,582
8 kW Class 27 8.23 kW 476 sq ft $2,060 $3,483
10 kW Class 33 10.06 kW 581 sq ft $2,518 $4,258

Which Sibling Wattage & Trim Variants Belong to This SEG Solar Inc Series?

All closely matched SEG Solar Inc wattages and cosmetic trims sharing the SEG Solar Inc SEG-BMB-305WW architecture. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the SEG Solar Inc SEG-BMB-305WW wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
SEG Solar Inc SEG-BMB-300WW 300.0 W 274.7 W 39.2 V 33.0 V 18.33%
SEG Solar Inc SEG-BMB-305WW 305.0 W 279.4 W 39.5 V 33.2 V 18.63%
SEG Solar Inc SEG-BMB-310WW 310.0 W 284.1 W 39.8 V 33.5 V 18.94%

How Many SEG Solar Inc SEG-BMB-305WW Modules Fit in a Cold-Weather String?

Maximum series module counts for SEG Solar Inc SEG-BMB-305WW from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=39.5V and beta_Voc=-0.296%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 44.76 V 13 panels 581.9 V 22 panels
-10 C (14 F) 43.59 V 13 panels 566.7 V 22 panels
0 C (32 F) 42.42 V 14 panels 593.9 V 23 panels
25 C (77 F STC) 39.5 V 15 panels 592.5 V 25 panels

Which Cross-Brand Solar Modules Compare Closest to SEG Solar Inc SEG-BMB-305WW?

Alternative CEC solar modules from competing brands near SEG Solar Inc SEG-BMB-305WW (305.0 W), including AXITEC AC-305M/60S.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-305M/60S
AXITEC
305.0 W Tie (0 W) 39.81 V 18.75% 91.2%
AXITEC AC-305M/60V
AXITEC
305.0 W Tie (0 W) 39.81 V 18.75% 91.2%
DuCal Solar Technology LLC DST305M-60
DuCal Solar Technology LLC
305.0 W Tie (0 W) 40.0 V 18.75% 90.3%
Enphase Energy Inc XACM-IQ7-LR6-60PB-305M
Enphase Energy Inc
305.0 W Tie (0 W) 40.2 V 19.3% 91.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for SEG Solar Inc SEG-BMB-305WW?

Evaluate SEG Solar Inc SEG-BMB-305WW (305.0 W STC, 39.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), SEG Solar Inc SEG-BMB-305WW reaches 44.76 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 27 panels for an 8 kW build require 476 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 27 panels (476 sq ft).
  • 2026 tax credit baseline: cash residential installs of SEG Solar Inc SEG-BMB-305WW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

SEG Solar Inc SEG-BMB-305WW 8 kW Residential Fit

Needs 27 modules (476 sq ft) with a 20 A string OCPD, offsetting ~$2,060/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare AXITEC AC-305M/60S.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 279.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for SEG Solar Inc SEG-BMB-305WW by SEG Solar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for SEG Solar Inc SEG-BMB-305WW?

Multiplying SEG Solar Inc SEG-BMB-305WW's 9.69 A short-circuit current by 1.56 equals 15.12 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can SEG Solar Inc SEG-BMB-305WW pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 43.59 V cold Voc at 14 F and handles 9.69 A Isc; string inverters cap SEG Solar Inc SEG-BMB-305WW at 13 panels on 600 V.

Is SEG Solar Inc SEG-BMB-305WW eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of SEG Solar Inc SEG-BMB-305WW rely on utility bill offset (~$2,060/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.