S-Energy Co Ltd SN340M-10(B) is a 340.0 W STC (302.0 W PTC) Mono-c-Si solar module ranking #13,575 of 21,677 CEC listings (below all-CEC median; higher than 36.1% of peers). It delivers 17.99% efficiency, 45.2 V Voc at 25 C, and 49.66 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 340.0 W
- PTC Wattage
- 302.0 W
- Voc @ 25C
- 45.2 V
- Efficiency
- 17.99%
How Does S-Energy Co Ltd SN340M-10(B) Compare Against Peer CEC Listings?
How S-Energy Co Ltd S-Energy Co Ltd SN340M-10(B) handles rooftop heat (302.0 W PTC), 8 kW sizing, and cold winter string voltage.
S-Energy Co Ltd builds the S-Energy Co Ltd SN340M-10(B) (Mono-c-Si) as a compact residential or specialty off-grid module delivering 179.9 W/m2 (1.92 percentage points below 19.91% CEC median). Compared against AXITEC AC-340M/72S (340.0 W), this model holds typical 88.8% PTC-to-STC thermal output (302.0 W real-world rating). Mid-range 45.2 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 14.63 A overcurrent floor served by a 15 A breaker.
Where Does S-Energy Co Ltd SN340M-10(B) Fall Across Listed CEC Models?
Where S-Energy Co Ltd SN340M-10(B) (340.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define S-Energy Co Ltd SN340M-10(B)?
Percentile placement of S-Energy Co Ltd SN340M-10(B) across power density (179.9 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for S-Energy Co Ltd SN340M-10(B)?
Four critical engineering numbers homeowners and solar installers check first when reviewing S-Energy Co Ltd SN340M-10(B) specifications.
340.0 W STC · Higher Than 36.1%
340.0 W STC (-45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.99% Aperture Efficiency
Power density 179.9 W/m2 (1.92 percentage points below 19.91% CEC median). PTC/STC ratio: 88.8% (rank #20,967).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 49.66 V at -10 C (595.9 V string) and 50.94 V at -20 C (11 max).
24 Panels = 8,160 W STC
Occupies 45.4 m2 (488 sq ft) producing 7,248 W PTC; NEC 690.8 OCPD floor is 14.63 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.2 * (1 + (-0.282/100) * (-10 - 25)) = 49.66 V | OCPD = 1.56 * 9.38 = 14.63 A
Inputs from CEC Modules.csv for S-Energy Co Ltd SN340M-10(B): Voc=45.2 V, beta_Voc=-0.282%/C, Isc=9.38 A, STC=340.0 W, Area=1.89 m2.
Result: 12 panels max on 600 V (595.9 V); 24 panels for 8 kW (488 sq ft).
What Are the Published CEC Specifications for S-Energy Co Ltd SN340M-10(B)?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for S-Energy Co Ltd SN340M-10(B).
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 340.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 302.0 W (88.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.38 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.7 V / 8.98 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.282 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.99% (1.89 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many S-Energy Co Ltd SN340M-10(B) Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using S-Energy Co Ltd SN340M-10(B) (340.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.12 kW | 366 sq ft | $1,532 | $2,590 |
| 8 kW Class | 24 | 8.16 kW | 488 sq ft | $2,042 | $3,454 |
| 10 kW Class | 30 | 10.2 kW | 610 sq ft | $2,553 | $4,317 |
Which Sibling Wattage & Trim Variants Belong to This S-Energy Co Ltd Series?
All closely matched S-Energy Co Ltd wattages and cosmetic trims sharing the S-Energy Co Ltd SN340M-10(B) architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| S-Energy Co Ltd SN330M-10(B) | 330.0 W | 292.8 W | 45.1 V | 37.1 V | 17.46% |
| S-Energy Co Ltd SN335M-10(B) | 335.0 W | 297.4 W | 45.2 V | 37.4 V | 17.72% |
| S-Energy Co Ltd SN340M-10(B) | 340.0 W | 302.0 W | 45.2 V | 37.7 V | 17.99% |
| S-Energy Co Ltd SN345M-10(B) | 345.0 W | 306.6 W | 45.3 V | 38.0 V | 18.25% |
How Many S-Energy Co Ltd SN340M-10(B) Modules Fit in a Cold-Weather String?
Maximum series module counts for S-Energy Co Ltd SN340M-10(B) from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 50.94 V | 11 panels | 560.3 V | 19 panels |
| -10 C (14 F) | 49.66 V | 12 panels | 595.9 V | 20 panels |
| 0 C (32 F) | 48.39 V | 12 panels | 580.7 V | 20 panels |
| 25 C (77 F STC) | 45.2 V | 13 panels | 587.6 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to S-Energy Co Ltd SN340M-10(B)?
Alternative CEC solar modules from competing brands near S-Energy Co Ltd SN340M-10(B) (340.0 W), including AXITEC AC-340M/72S.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| AXITEC AC-340M/72S AXITEC |
340.0 W | Tie (0 W) | 46.16 V | 17.62% | 91.1% |
| AXITEC AC-340M/72V AXITEC |
340.0 W | Tie (0 W) | 46.16 V | 17.62% | 91.1% |
| GCL System Integration Technology Co Ltd GCL-M6/72340 GCL System Integration Technology Co Ltd |
340.0 W | Tie (0 W) | 46.6 V | 17.53% | 90.5% |
| GCL System Integration Technology Co Ltd GCL-M6/72H340 GCL System Integration Technology Co Ltd |
340.0 W | Tie (0 W) | 46.6 V | 17.53% | 91.4% |
What Are the Design Limits and Best-Fit Uses for S-Energy Co Ltd SN340M-10(B)?
Evaluate S-Energy Co Ltd SN340M-10(B) (340.0 W STC, 45.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), S-Energy Co Ltd SN340M-10(B) reaches 50.94 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 488 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (488 sq ft).
- 2026 tax credit baseline: cash residential installs of S-Energy Co Ltd SN340M-10(B) carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
S-Energy Co Ltd SN340M-10(B) 8 kW Residential Fit
Needs 24 modules (488 sq ft) with a 15 A string OCPD, offsetting ~$2,042/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare AXITEC AC-340M/72S.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 302.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for S-Energy Co Ltd SN340M-10(B) by S-Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for S-Energy Co Ltd SN340M-10(B)?
Multiplying S-Energy Co Ltd SN340M-10(B)'s 9.38 A short-circuit current by 1.56 equals 14.63 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can S-Energy Co Ltd SN340M-10(B) pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 49.66 V cold Voc at 14 F and handles 9.38 A Isc; string inverters cap S-Energy Co Ltd SN340M-10(B) at 12 panels on 600 V.
Is S-Energy Co Ltd SN340M-10(B) eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of S-Energy Co Ltd SN340M-10(B) rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)