Manufacturer: S-Energy Co Ltd Registry: CEC Verified Engineering Specification

S-Energy Co Ltd SD25-72BDE-365V is a 365.0 W STC (340.6 W PTC) Mono-c-Si solar module ranking #12,044 of 21,677 CEC listings (below all-CEC median; higher than 42.9% of peers). It delivers 18.34% efficiency, 47.9 V Voc at 25 C, and 52.36 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
365.0 W
PTC Wattage
340.6 W
Voc @ 25C
47.9 V
Efficiency
18.34%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does S-Energy Co Ltd SD25-72BDE-365V Compare Against Peer CEC Listings?

Solar engineering breakdown for S-Energy Co Ltd SD25-72BDE-365V: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from S-Energy Co Ltd and peers, S-Energy Co Ltd SD25-72BDE-365V stands 45.0 W below the 410.0 W Mono-c-Si median and strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Sizing 6 kW (17 panels) to 10 kW (28 panels) yields $1,554-$2,558/yr in baseline US bill offset. Mid-range 47.9 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does S-Energy Co Ltd SD25-72BDE-365V Fall Across Listed CEC Models?

Distribution marker showing S-Energy Co Ltd SD25-72BDE-365V (365.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where S-Energy Co Ltd SD25-72BDE-365V (365.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCS-Energy Co Ltd SD: 365.0 W

What Dataset Percentiles Define S-Energy Co Ltd SD25-72BDE-365V?

Dataset percentiles tracking S-Energy Co Ltd SD25-72BDE-365V power output, thermal retention ratio, and aperture efficiency against 21,677 models.

S-Energy Co Ltd SD25-72BDE-365V Engineering BenchmarksPercentile comparison of S-Energy Co Ltd SD25-72BDE-365V wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage365.0 WPTC/STC Retention93.3%Module Efficiency18.34%

What Do the Dataset Ranks Show for S-Energy Co Ltd SD25-72BDE-365V?

Benchmark highlights for S-Energy Co Ltd SD25-72BDE-365V covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #12,044 / 21,677

365.0 W STC · Higher Than 42.9%

365.0 W STC (-20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,581

18.34% Aperture Efficiency

Power density 183.4 W/m2 (1.57 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.36 V at -10 C (576.0 V string) and 53.63 V at -20 C (11 max).

8 kW Reference Array

22 Panels = 8,030 W STC

Occupies 43.8 m2 (471 sq ft) producing 7,493 W PTC; NEC 690.8 OCPD floor is 15.16 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.9 * (1 + (-0.266/100) * (-10 - 25)) = 52.36 V | OCPD = 1.56 * 9.72 = 15.16 A

Inputs from CEC Modules.csv for S-Energy Co Ltd SD25-72BDE-365V: Voc=47.9 V, beta_Voc=-0.266%/C, Isc=9.72 A, STC=365.0 W, Area=1.99 m2.

Result: 11 panels max on 600 V (576.0 V); 22 panels for 8 kW (471 sq ft).

What Are the Published CEC Specifications for S-Energy Co Ltd SD25-72BDE-365V?

Official CEC datasheet figures for S-Energy Co Ltd SD25-72BDE-365V (Mono-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for S-Energy Co Ltd SD25-72BDE-365V.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 365.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 340.6 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.72 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.5 V / 9.25 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.34% (1.99 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many S-Energy Co Ltd SD25-72BDE-365V Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many S-Energy Co Ltd SD25-72BDE-365V modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.21 kW 364 sq ft $1,554 $2,628
8 kW Class 22 8.03 kW 471 sq ft $2,010 $3,398
10 kW Class 28 10.22 kW 600 sq ft $2,558 $4,325

Which Sibling Wattage & Trim Variants Belong to This S-Energy Co Ltd Series?

Consolidated S-Energy Co Ltd wattage variants sharing the S-Energy Co Ltd SD25-72BDE-365V mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the S-Energy Co Ltd SD25-72BDE-365V wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
S-Energy Co Ltd SD25-72BDE-360V 360.0 W 335.8 W 47.7 V 39.2 V 18.09%
S-Energy Co Ltd SD25-72BDE-365V 365.0 W 340.6 W 47.9 V 39.5 V 18.34%
S-Energy Co Ltd SD25-72BDE-370V 370.0 W 345.3 W 48.2 V 39.7 V 18.59%

How Many S-Energy Co Ltd SD25-72BDE-365V Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on S-Energy Co Ltd SD25-72BDE-365V (52.36 V at 14 F).

Computed from Voc=47.9V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.63 V 11 panels 589.9 V 18 panels
-10 C (14 F) 52.36 V 11 panels 576.0 V 19 panels
0 C (32 F) 51.09 V 11 panels 562.0 V 19 panels
25 C (77 F STC) 47.9 V 12 panels 574.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to S-Energy Co Ltd SD25-72BDE-365V?

Competing CEC solar panels closest to S-Energy Co Ltd SD25-72BDE-365V in nameplate wattage and Voc, starting with Auxin Solar AXN6M612B360.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6M612B360
Auxin Solar
360.0 W -5.0 W 47.56 V 18.28% 93.0%
CSI Solar Co Ltd CS3U-360MB-AG
CSI Solar Co Ltd
360.0 W -5.0 W 47.0 V 18.56% 93.8%
CSI Solar Co Ltd CS3U-360PB-AG
CSI Solar Co Ltd
360.0 W -5.0 W 47.0 V 18.56% 92.5%
Auxin Solar AXN6M612B380
Auxin Solar
380.0 W +15.0 W 47.94 V 19.3% 93.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for S-Energy Co Ltd SD25-72BDE-365V?

Evaluate S-Energy Co Ltd SD25-72BDE-365V (365.0 W STC, 47.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), S-Energy Co Ltd SD25-72BDE-365V reaches 53.63 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 471 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (471 sq ft).
  • 2026 tax credit baseline: cash residential installs of S-Energy Co Ltd SD25-72BDE-365V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

S-Energy Co Ltd SD25-72BDE-365V 8 kW Residential Fit

Needs 22 modules (471 sq ft) with a 20 A string OCPD, offsetting ~$2,010/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6M612B360.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 340.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for S-Energy Co Ltd SD25-72BDE-365V by S-Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for S-Energy Co Ltd SD25-72BDE-365V?

Multiplying S-Energy Co Ltd SD25-72BDE-365V's 9.72 A short-circuit current by 1.56 equals 15.16 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can S-Energy Co Ltd SD25-72BDE-365V pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.36 V cold Voc at 14 F and handles 9.72 A Isc; string inverters cap S-Energy Co Ltd SD25-72BDE-365V at 11 panels on 600 V.

Is S-Energy Co Ltd SD25-72BDE-365V eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of S-Energy Co Ltd SD25-72BDE-365V rely on utility bill offset (~$2,010/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.