Manufacturer: Regitec Solar BV Registry: CEC Verified Engineering Specification

Regitec Solar BV RMHT72/570S3 is a 570.0 W STC (535.5 W PTC) Mono-c-Si solar module ranking #2,154 of 21,677 CEC listings (top 10.5%; higher than 89.5% of peers). It delivers 22.09% efficiency, 51.07 V Voc at 25 C, and 55.49 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
570.0 W
PTC Wattage
535.5 W
Voc @ 25C
51.07 V
Efficiency
22.09%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Regitec Solar BV RMHT72/570S3 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Regitec Solar BV RMHT72/570S3 (Mono-c-Si) residential solar systems.

Regitec Solar BV RMHT72/570S3 delivers 220.9 W/m2 (2.18 percentage points above 19.91% CEC median) and strong 93.9% PTC-to-STC heat retention (#5,210 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 56.75 V per unit, capping 600 V circuits at 10 panels. Compare specs directly with AE Solar GmbH AE570CMD-144BDS (570.0 W).

Where Does Regitec Solar BV RMHT72/570S3 Fall Across Listed CEC Models?

Comparison of Regitec Solar BV RMHT72/570S3 (570.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Regitec Solar BV RMHT72/570S3 (570.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCRegitec Solar BV R: 570.0 W

What Dataset Percentiles Define Regitec Solar BV RMHT72/570S3?

Relative ranking of Regitec Solar BV RMHT72/570S3 across nameplate watts, 93.9% PTC thermal ratio, and module aperture efficiency.

Regitec Solar BV RMHT72/570S3 Engineering BenchmarksPercentile comparison of Regitec Solar BV RMHT72/570S3 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage570.0 WPTC/STC Retention93.9%Module Efficiency22.09%

What Do the Dataset Ranks Show for Regitec Solar BV RMHT72/570S3?

Summary of Regitec Solar BV RMHT72/570S3 output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #2,154 / 21,677

Top 10.5% STC Output

570.0 W STC (+185.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,842

22.09% Aperture Efficiency

Power density 220.9 W/m2 (2.18 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.49 V at -10 C (554.9 V string) and 56.75 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,550 W STC

Occupies 38.7 m2 (417 sq ft) producing 8,032 W PTC; NEC 690.8 OCPD floor is 22.23 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 51.07 * (1 + (-0.247/100) * (-10 - 25)) = 55.49 V | OCPD = 1.56 * 14.25 = 22.23 A

Inputs from CEC Modules.csv for Regitec Solar BV RMHT72/570S3: Voc=51.07 V, beta_Voc=-0.247%/C, Isc=14.25 A, STC=570.0 W, Area=2.58 m2.

Result: 10 panels max on 600 V (554.9 V); 15 panels for 8 kW (417 sq ft).

What Are the Published CEC Specifications for Regitec Solar BV RMHT72/570S3?

Complete CEC test sheet for Regitec Solar BV RMHT72/570S3 including Isc (14.25 A), Voc (51.07 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Regitec Solar BV RMHT72/570S3.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 570.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 535.5 W (93.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 51.07 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.25 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.29 V / 13.48 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.247 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.09% (2.58 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Regitec Solar BV RMHT72/570S3 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Regitec Solar BV RMHT72/570S3.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.27 kW 305 sq ft $1,569 $2,654
8 kW Class 15 8.55 kW 417 sq ft $2,140 $3,619
10 kW Class 18 10.26 kW 500 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Regitec Solar BV Series?

Related Regitec Solar BV power steps and black/silver trims consolidated into this Regitec Solar BV RMHT72/570S3 series guide.

Sibling CEC listings grouped into the Regitec Solar BV RMHT72/570S3 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Regitec Solar BV RMHT72/575S3 565.0 W 530.7 W 51.27 V 42.44 V 21.9%
Regitec Solar BV RMHT72/570S3 570.0 W 535.5 W 51.07 V 42.29 V 22.09%
Regitec Solar BV RMHT72/580S3 570.0 W 535.5 W 51.47 V 42.59 V 22.09%

How Many Regitec Solar BV RMHT72/570S3 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Regitec Solar BV RMHT72/570S3 (51.07 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=51.07V and beta_Voc=-0.247%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.75 V 10 panels 567.5 V 17 panels
-10 C (14 F) 55.49 V 10 panels 554.9 V 18 panels
0 C (32 F) 54.22 V 11 panels 596.4 V 18 panels
25 C (77 F STC) 51.07 V 11 panels 561.8 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Regitec Solar BV RMHT72/570S3?

Four comparable CEC modules such as AE Solar GmbH AE570CMD-144BDS (570.0 W) for side-by-side solar quote checks. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AE Solar GmbH AE570CMD-144BDS
AE Solar GmbH
570.0 W Tie (0 W) 51.2 V 22.09% 95.2%
DE SOLAR(S) PTE LTD DE570-144BG-182S-N/WW
DE SOLAR(S) PTE LTD
570.0 W Tie (0 W) 51.2 V 22.09% 95.2%
Aptos Solar Technology LLC DNA-144-BFN10-570W-DG
Aptos Solar Technology LLC
570.0 W Tie (0 W) 50.74 V 22.09% 94.9%
AEG SOLAR ENERGY SRL ALPS72D30-570/TP
AEG SOLAR ENERGY SRL
570.0 W Tie (0 W) 52.1 V 22.09% 94.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Regitec Solar BV RMHT72/570S3?

Evaluate Regitec Solar BV RMHT72/570S3 (570.0 W STC, 51.07 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Regitec Solar BV RMHT72/570S3 reaches 56.75 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Regitec Solar BV RMHT72/570S3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Regitec Solar BV RMHT72/570S3 8 kW Residential Fit

Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,140/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare AE Solar GmbH AE570CMD-144BDS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 535.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Regitec Solar BV RMHT72/570S3 by Regitec Solar BV grounded in CEC test data and NEC 690.7/690.8 limits.

How many Regitec Solar BV RMHT72/570S3 panels fit on a 600 V winter solar string?

At -10 C (14 F), Regitec Solar BV RMHT72/570S3 cold Voc rises from 51.07 V to 55.49 V (beta_Voc -0.247%/C), capping a 600 V string at 10 panels (554.9 V).

How much roof area does an 8 kW array of Regitec Solar BV RMHT72/570S3 need?

An 8 kW DC system uses 15 Regitec Solar BV RMHT72/570S3 modules (8,550 W STC / 8,032 W PTC), covering roughly 417 sq ft and saving ~$2,140/yr at 18.54 c/kWh.

How does Regitec Solar BV RMHT72/570S3 compare against AE Solar GmbH AE570CMD-144BDS?

Regitec Solar BV RMHT72/570S3 outputs 570.0 W STC (51.07 V Voc, rank #2,154 of 21,677), while AE Solar GmbH AE570CMD-144BDS delivers 570.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.