Regitec Solar BV RMHT72/570S2 is a 570.0 W STC (537.7 W PTC) Mono-c-Si solar module ranking #2,154 of 21,677 CEC listings (top 10.5%; higher than 89.5% of peers). It delivers 22.09% efficiency, 51.07 V Voc at 25 C, and 55.56 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 570.0 W
- PTC Wattage
- 537.7 W
- Voc @ 25C
- 51.07 V
- Efficiency
- 22.09%
How Does Regitec Solar BV RMHT72/570S2 Compare Against Peer CEC Listings?
How Regitec Solar BV Regitec Solar BV RMHT72/570S2 handles rooftop heat (537.7 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Regitec Solar BV RMHT72/570S2 exhibits 14.25 A short-circuit current, requiring a 22.23 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #2,154 of 21,677 (160.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 38.7 m2 for an 8 kW system (18 panels for 10 kW). Higher 51.07 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does Regitec Solar BV RMHT72/570S2 Fall Across Listed CEC Models?
Where Regitec Solar BV RMHT72/570S2 (570.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Regitec Solar BV RMHT72/570S2?
Percentile placement of Regitec Solar BV RMHT72/570S2 across power density (220.9 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Regitec Solar BV RMHT72/570S2?
Four critical engineering numbers homeowners and solar installers check first when reviewing Regitec Solar BV RMHT72/570S2 specifications.
Top 10.5% STC Output
570.0 W STC (+185.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.09% Aperture Efficiency
Power density 220.9 W/m2 (2.18 percentage points above 19.91% CEC median). PTC/STC ratio: 94.3% (rank #3,231).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 55.56 V at -10 C (555.6 V string) and 56.84 V at -20 C (10 max).
15 Panels = 8,550 W STC
Occupies 38.7 m2 (417 sq ft) producing 8,066 W PTC; NEC 690.8 OCPD floor is 22.23 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 51.07 * (1 + (-0.251/100) * (-10 - 25)) = 55.56 V | OCPD = 1.56 * 14.25 = 22.23 A
Inputs from CEC Modules.csv for Regitec Solar BV RMHT72/570S2: Voc=51.07 V, beta_Voc=-0.251%/C, Isc=14.25 A, STC=570.0 W, Area=2.58 m2.
Result: 10 panels max on 600 V (555.6 V); 15 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for Regitec Solar BV RMHT72/570S2?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Regitec Solar BV RMHT72/570S2.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 570.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 537.7 W (94.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 51.07 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.25 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 42.3 V / 13.48 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.251 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.09% (2.58 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Regitec Solar BV RMHT72/570S2 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Regitec Solar BV RMHT72/570S2 (570.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 11 | 6.27 kW | 305 sq ft | $1,569 | $2,654 |
| 8 kW Class | 15 | 8.55 kW | 417 sq ft | $2,140 | $3,619 |
| 10 kW Class | 18 | 10.26 kW | 500 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Regitec Solar BV Series?
All closely matched Regitec Solar BV wattages and cosmetic trims sharing the Regitec Solar BV RMHT72/570S2 architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Regitec Solar BV RMHT72/565S2 | 565.0 W | 532.9 W | 50.87 V | 42.15 V | 21.9% |
| Regitec Solar BV RMHT72/570S2 | 570.0 W | 537.7 W | 51.07 V | 42.3 V | 22.09% |
How Many Regitec Solar BV RMHT72/570S2 Modules Fit in a Cold-Weather String?
Maximum series module counts for Regitec Solar BV RMHT72/570S2 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 56.84 V | 10 panels | 568.4 V | 17 panels |
| -10 C (14 F) | 55.56 V | 10 panels | 555.6 V | 17 panels |
| 0 C (32 F) | 54.27 V | 11 panels | 597.0 V | 18 panels |
| 25 C (77 F STC) | 51.07 V | 11 panels | 561.8 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to Regitec Solar BV RMHT72/570S2?
Alternative CEC solar modules from competing brands near Regitec Solar BV RMHT72/570S2 (570.0 W), including Gautam Solar Pvt Ltd G2G1710-HAD.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Gautam Solar Pvt Ltd G2G1710-HAD Gautam Solar Pvt Ltd |
570.0 W | Tie (0 W) | 50.74 V | 22.2% | 95.1% |
| Gautam Solar Pvt Ltd G2X1710N-UHAD Gautam Solar Pvt Ltd |
570.0 W | Tie (0 W) | 50.74 V | 22.18% | 94.9% |
| CSI Solar Co Ltd CS6W-570TB-AG CSI Solar Co Ltd |
570.0 W | Tie (0 W) | 51.8 V | 22.71% | 94.9% |
| Gautam Solar Pvt Ltd G2G1725-HAD Gautam Solar Pvt Ltd |
575.0 W | +5.0 W | 50.89 V | 22.4% | 95.1% |
What Are the Design Limits and Best-Fit Uses for Regitec Solar BV RMHT72/570S2?
Evaluate Regitec Solar BV RMHT72/570S2 (570.0 W STC, 51.07 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Regitec Solar BV RMHT72/570S2 reaches 56.84 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Regitec Solar BV RMHT72/570S2 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Regitec Solar BV RMHT72/570S2 8 kW Residential Fit
Needs 15 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,140/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Gautam Solar Pvt Ltd G2G1710-HAD.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 537.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Regitec Solar BV RMHT72/570S2 by Regitec Solar BV grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Regitec Solar BV RMHT72/570S2 PTC wattage (537.7 W) lower than STC (570.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 537.7 W PTC (94.3% retention) across Regitec Solar BV RMHT72/570S2's 2.58 m2 aperture.
Who should skip Regitec Solar BV RMHT72/570S2 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Regitec Solar BV RMHT72/570S2 panels (417 sq ft) leave unusable roof gaps vs. Gautam Solar Pvt Ltd G2G1710-HAD.
What is the 1,000 V commercial string limit for Regitec Solar BV RMHT72/570S2?
On 1,000 V commercial inverters at -10 C (55.56 V cold Voc), Regitec Solar BV RMHT72/570S2 fits up to 17 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)