Regitec Solar BV RMHT54/425AB3 is a 425.0 W STC (399.2 W PTC) Mono-c-Si solar module ranking #7,622 of 21,677 CEC listings (top 36.5%; higher than 63.5% of peers). It delivers 21.79% efficiency, 38.3 V Voc at 25 C, and 41.61 V cold Voc at -10 C (14 panels max per 600 V string).
- STC Wattage
- 425.0 W
- PTC Wattage
- 399.2 W
- Voc @ 25C
- 38.3 V
- Efficiency
- 21.79%
How Does Regitec Solar BV RMHT54/425AB3 Compare Against Peer CEC Listings?
How Regitec Solar BV Regitec Solar BV RMHT54/425AB3 handles rooftop heat (399.2 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, Regitec Solar BV RMHT54/425AB3 exhibits 14.15 A short-circuit current, requiring a 22.07 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #7,622 of 21,677 (15.0 W above the 410.0 W Mono-c-Si median), this modern high-density residential and light-commercial module covers 37.0 m2 for an 8 kW system (24 panels for 10 kW). Lower 38.3 V string voltage fits 14 panels in series at 14 F and pairs easily with microinverters.
Where Does Regitec Solar BV RMHT54/425AB3 Fall Across Listed CEC Models?
Where Regitec Solar BV RMHT54/425AB3 (425.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Regitec Solar BV RMHT54/425AB3?
Percentile placement of Regitec Solar BV RMHT54/425AB3 across power density (217.9 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Regitec Solar BV RMHT54/425AB3?
Four critical engineering numbers homeowners and solar installers check first when reviewing Regitec Solar BV RMHT54/425AB3 specifications.
Top 36.5% STC Output
425.0 W STC (+40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.79% Aperture Efficiency
Power density 217.9 W/m2 (1.88 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).
14 Panels Max @ -10 C (600 V)
Cold Voc reaches 41.61 V at -10 C (582.5 V string) and 42.56 V at -20 C (14 max).
19 Panels = 8,075 W STC
Occupies 37.0 m2 (399 sq ft) producing 7,585 W PTC; NEC 690.8 OCPD floor is 22.07 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 38.3 * (1 + (-0.247/100) * (-10 - 25)) = 41.61 V | OCPD = 1.56 * 14.15 = 22.07 A
Inputs from CEC Modules.csv for Regitec Solar BV RMHT54/425AB3: Voc=38.3 V, beta_Voc=-0.247%/C, Isc=14.15 A, STC=425.0 W, Area=1.95 m2.
Result: 14 panels max on 600 V (582.5 V); 19 panels for 8 kW (399 sq ft).
What Are the Published CEC Specifications for Regitec Solar BV RMHT54/425AB3?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Regitec Solar BV RMHT54/425AB3.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 425.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 399.2 W (93.9% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 38.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.15 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 31.7 V / 13.41 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.247 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.79% (1.95 m2) | Array roof footprint density |
| Cell Count & Technology | 54 cells (Mono-c-Si) | Monofacial backsheet |
How Many Regitec Solar BV RMHT54/425AB3 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Regitec Solar BV RMHT54/425AB3 (425.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.38 kW | 315 sq ft | $1,597 | $2,700 |
| 8 kW Class | 19 | 8.07 kW | 399 sq ft | $2,020 | $3,415 |
| 10 kW Class | 24 | 10.2 kW | 504 sq ft | $2,553 | $4,317 |
How Many Regitec Solar BV RMHT54/425AB3 Modules Fit in a Cold-Weather String?
Maximum series module counts for Regitec Solar BV RMHT54/425AB3 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 42.56 V | 14 panels | 595.8 V | 23 panels |
| -10 C (14 F) | 41.61 V | 14 panels | 582.5 V | 24 panels |
| 0 C (32 F) | 40.67 V | 14 panels | 569.4 V | 24 panels |
| 25 C (77 F STC) | 38.3 V | 15 panels | 574.5 V | 26 panels |
Which Cross-Brand Solar Modules Compare Closest to Regitec Solar BV RMHT54/425AB3?
Alternative CEC solar modules from competing brands near Regitec Solar BV RMHT54/425AB3 (425.0 W), including Auxin Solar AXN10M420W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN10M420W Auxin Solar |
420.0 W | -5.0 W | 38.26 V | 21.65% | 93.2% |
| Aptos Solar Technology LLC DNA-108-MFN10-420W Aptos Solar Technology LLC |
420.0 W | -5.0 W | 38.5 V | 21.65% | 95.0% |
| Elin Energy (Sirius PV) ELNSM54M-HC-LV-N-420 Elin Energy (Sirius PV) |
420.0 W | -5.0 W | 38.5 V | 21.65% | 94.9% |
| Elin Energy (Sirius PV) ELNSM54M-HC-N-420 Elin Energy (Sirius PV) |
420.0 W | -5.0 W | 38.5 V | 21.65% | 94.9% |
What Are the Design Limits and Best-Fit Uses for Regitec Solar BV RMHT54/425AB3?
Evaluate Regitec Solar BV RMHT54/425AB3 (425.0 W STC, 38.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Regitec Solar BV RMHT54/425AB3 reaches 42.56 V per panel—exceeding 14 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 399 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (399 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Regitec Solar BV RMHT54/425AB3 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Regitec Solar BV RMHT54/425AB3 8 kW Residential Fit
Needs 19 modules (399 sq ft) with a 25 A string OCPD, offsetting ~$2,020/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 14 panels (-10 C) or 14 panels (-20 C), or compare Auxin Solar AXN10M420W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 399.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Regitec Solar BV RMHT54/425AB3 by Regitec Solar BV grounded in CEC test data and NEC 690.7/690.8 limits.
Why is Regitec Solar BV RMHT54/425AB3 PTC wattage (399.2 W) lower than STC (425.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 399.2 W PTC (93.9% retention) across Regitec Solar BV RMHT54/425AB3's 1.95 m2 aperture.
Who should skip Regitec Solar BV RMHT54/425AB3 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 Regitec Solar BV RMHT54/425AB3 panels (399 sq ft) leave unusable roof gaps vs. Auxin Solar AXN10M420W.
What is the 1,000 V commercial string limit for Regitec Solar BV RMHT54/425AB3?
On 1,000 V commercial inverters at -10 C (41.61 V cold Voc), Regitec Solar BV RMHT54/425AB3 fits up to 24 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)