RECOM SILLIA RCM-295-6MB is a 295.0 W STC (270.9 W PTC) Mono-c-Si solar module ranking #16,890 of 21,677 CEC listings (below all-CEC median; higher than 20.4% of peers). It delivers 18.32% efficiency, 39.6 V Voc at 25 C, and 43.92 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 295.0 W
- PTC Wattage
- 270.9 W
- Voc @ 25C
- 39.6 V
- Efficiency
- 18.32%
How Does RECOM SILLIA RCM-295-6MB Compare Against Peer CEC Listings?
Solar engineering breakdown for RECOM SILLIA RCM-295-6MB: PTC thermal retention, roof footprint, and cold Voc string bounds. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Across 5,889 Mono-c-Si listings from RECOM SILLIA and peers, RECOM SILLIA RCM-295-6MB stands 115.0 W below the 410.0 W Mono-c-Si median and strong 91.8% PTC-to-STC heat retention (#14,745 of 21,677). Sizing 6 kW (21 panels) to 10 kW (34 panels) yields $1,552-$2,510/yr in baseline US bill offset. Lower 39.6 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.
Where Does RECOM SILLIA RCM-295-6MB Fall Across Listed CEC Models?
Distribution marker showing RECOM SILLIA RCM-295-6MB (295.0 W) relative to the 385.0 W all-CEC solar panel median. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Dataset Percentiles Define RECOM SILLIA RCM-295-6MB?
Dataset percentiles tracking RECOM SILLIA RCM-295-6MB power output, thermal retention ratio, and aperture efficiency against 21,677 models. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for RECOM SILLIA RCM-295-6MB?
Benchmark highlights for RECOM SILLIA RCM-295-6MB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
295.0 W STC · Higher Than 20.4%
295.0 W STC (-90.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
18.32% Aperture Efficiency
Power density 183.2 W/m2 (1.59 percentage points below 19.91% CEC median). PTC/STC ratio: 91.8% (rank #14,745).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.92 V at -10 C (571.0 V string) and 45.16 V at -20 C (13 max).
28 Panels = 8,260 W STC
Occupies 45.1 m2 (485 sq ft) producing 7,585 W PTC; NEC 690.8 OCPD floor is 14.9 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.6 * (1 + (-0.312/100) * (-10 - 25)) = 43.92 V | OCPD = 1.56 * 9.55 = 14.9 A
Inputs from CEC Modules.csv for RECOM SILLIA RCM-295-6MB: Voc=39.6 V, beta_Voc=-0.312%/C, Isc=9.55 A, STC=295.0 W, Area=1.61 m2.
Result: 13 panels max on 600 V (571.0 V); 28 panels for 8 kW (485 sq ft).
What Are the Published CEC Specifications for RECOM SILLIA RCM-295-6MB?
Official CEC datasheet figures for RECOM SILLIA RCM-295-6MB (Mono-c-Si) used in utility interconnection and permit reviews. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 295.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 270.9 W (91.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.55 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.6 V / 9.05 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.312 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.32% (1.61 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many RECOM SILLIA RCM-295-6MB Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many RECOM SILLIA RCM-295-6MB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 21 | 6.2 kW | 364 sq ft | $1,552 | $2,624 |
| 8 kW Class | 28 | 8.26 kW | 485 sq ft | $2,067 | $3,496 |
| 10 kW Class | 34 | 10.03 kW | 589 sq ft | $2,510 | $4,245 |
How Many RECOM SILLIA RCM-295-6MB Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on RECOM SILLIA RCM-295-6MB (43.92 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.16 V | 13 panels | 587.1 V | 22 panels |
| -10 C (14 F) | 43.92 V | 13 panels | 571.0 V | 22 panels |
| 0 C (32 F) | 42.69 V | 14 panels | 597.7 V | 23 panels |
| 25 C (77 F STC) | 39.6 V | 15 panels | 594.0 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to RECOM SILLIA RCM-295-6MB?
Competing CEC solar panels closest to RECOM SILLIA RCM-295-6MB in nameplate wattage and Voc, starting with GCL System Integration Technology Co Ltd GCL-M6/60295.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| GCL System Integration Technology Co Ltd GCL-M6/60295 GCL System Integration Technology Co Ltd |
295.0 W | Tie (0 W) | 39.3 V | 18.1% | 90.2% |
| CSI Solar Co Ltd CS3K-295MS CSI Solar Co Ltd |
295.0 W | Tie (0 W) | 39.1 V | 18.4% | 93.0% |
| DualSun SAS DualSun 290M-60-00 DualSun SAS |
290.0 W | -5.0 W | 39.7 V | 17.68% | 90.9% |
| CertainTeed CT290M10-02 CertainTeed |
290.0 W | -5.0 W | 39.77 V | 17.83% | 91.8% |
What Are the Design Limits and Best-Fit Uses for RECOM SILLIA RCM-295-6MB?
Evaluate RECOM SILLIA RCM-295-6MB (295.0 W STC, 39.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), RECOM SILLIA RCM-295-6MB reaches 45.16 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 28 panels for an 8 kW build require 485 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 28 panels (485 sq ft).
- 2026 tax credit baseline: cash residential installs of RECOM SILLIA RCM-295-6MB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
RECOM SILLIA RCM-295-6MB 8 kW Residential Fit
Needs 28 modules (485 sq ft) with a 15 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare GCL System Integration Technology Co Ltd GCL-M6/60295.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 270.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for RECOM SILLIA RCM-295-6MB by RECOM SILLIA grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for RECOM SILLIA RCM-295-6MB?
Multiplying RECOM SILLIA RCM-295-6MB's 9.55 A short-circuit current by 1.56 equals 14.9 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can RECOM SILLIA RCM-295-6MB pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 43.92 V cold Voc at 14 F and handles 9.55 A Isc; string inverters cap RECOM SILLIA RCM-295-6MB at 13 panels on 600 V.
Is RECOM SILLIA RCM-295-6MB eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of RECOM SILLIA RCM-295-6MB rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)