REC Group REC610AA Pro MG is a 610.0 W STC (581.5 W PTC) Mono-c-Si solar module ranking #1,104 of 21,677 CEC listings (top 5.6%; higher than 94.4% of peers). It delivers 22.02% efficiency, 44.4 V Voc at 25 C, and 48.01 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 610.0 W
- PTC Wattage
- 581.5 W
- Voc @ 25C
- 44.4 V
- Efficiency
- 22.02%
How Does REC Group REC610AA Pro MG Compare Against Peer CEC Listings?
Solar engineering breakdown for REC Group REC610AA Pro MG: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 610.0 W STC and 581.5 W PTC, REC Group REC610AA Pro MG sits +225.0 W vs all-CEC median (top 5.6%; higher than 94.4% of peers) among 21,677 listed modules. Power density reaches 220.2 W/m2 (2.11 percentage points above 19.91% CEC median). Mid-range 44.4 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer KOSOL ENERGIE PVT LTD KE-620-66XU rates 620.0 W.
Where Does REC Group REC610AA Pro MG Fall Across Listed CEC Models?
Distribution marker showing REC Group REC610AA Pro MG (610.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define REC Group REC610AA Pro MG?
Dataset percentiles tracking REC Group REC610AA Pro MG power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for REC Group REC610AA Pro MG?
Benchmark highlights for REC Group REC610AA Pro MG covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 5.6% STC Output
610.0 W STC (+225.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.02% Aperture Efficiency
Power density 220.2 W/m2 (2.11 percentage points above 19.91% CEC median). PTC/STC ratio: 95.3% (rank #237).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 48.01 V at -10 C (576.1 V string) and 49.04 V at -20 C (12 max).
14 Panels = 8,540 W STC
Occupies 38.8 m2 (417 sq ft) producing 8,141 W PTC; NEC 690.8 OCPD floor is 27.39 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.4 * (1 + (-0.232/100) * (-10 - 25)) = 48.01 V | OCPD = 1.56 * 17.56 = 27.39 A
Inputs from CEC Modules.csv for REC Group REC610AA Pro MG: Voc=44.4 V, beta_Voc=-0.232%/C, Isc=17.56 A, STC=610.0 W, Area=2.77 m2.
Result: 12 panels max on 600 V (576.1 V); 14 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for REC Group REC610AA Pro MG?
Official CEC datasheet figures for REC Group REC610AA Pro MG (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 610.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 581.5 W (95.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 17.56 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.3 V / 16.81 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.232 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.02% (2.77 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many REC Group REC610AA Pro MG Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many REC Group REC610AA Pro MG modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.1 kW | 298 sq ft | $1,527 | $2,582 |
| 8 kW Class | 14 | 8.54 kW | 417 sq ft | $2,137 | $3,614 |
| 10 kW Class | 17 | 10.37 kW | 507 sq ft | $2,596 | $4,389 |
Which Sibling Wattage & Trim Variants Belong to This REC Group Series?
Consolidated REC Group wattage variants sharing the REC Group REC610AA Pro MG mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| REC Group REC600AA Pro MG | 600.0 W | 571.8 W | 44.2 V | 36.0 V | 21.66% |
| REC Group REC610AA Pro MG | 610.0 W | 581.5 W | 44.4 V | 36.3 V | 22.02% |
| REC Group REC620AA Pro MG | 620.0 W | 591.2 W | 44.6 V | 36.6 V | 22.38% |
How Many REC Group REC610AA Pro MG Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on REC Group REC610AA Pro MG (48.01 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 49.04 V | 12 panels | 588.5 V | 20 panels |
| -10 C (14 F) | 48.01 V | 12 panels | 576.1 V | 20 panels |
| 0 C (32 F) | 46.98 V | 12 panels | 563.8 V | 21 panels |
| 25 C (77 F STC) | 44.4 V | 13 panels | 577.2 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to REC Group REC610AA Pro MG?
Competing CEC solar panels closest to REC Group REC610AA Pro MG in nameplate wattage and Voc, starting with KOSOL ENERGIE PVT LTD KE-620-66XU.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| KOSOL ENERGIE PVT LTD KE-620-66XU KOSOL ENERGIE PVT LTD |
620.0 W | +10.0 W | 44.6 V | 19.87% | 93.7% |
| G-Star Pte Ltd GSD8J60M-605BT G-Star Pte Ltd |
605.0 W | -5.0 W | 41.8 V | 21.53% | 94.2% |
| G-Star Pte Ltd GSD8J60M-605WT G-Star Pte Ltd |
605.0 W | -5.0 W | 41.8 V | 21.53% | 94.2% |
| Hansol Technics Co Ltd HA605ZB-GGFA0 Hansol Technics Co Ltd |
605.0 W | -5.0 W | 41.8 V | 21.53% | 94.2% |
What Are the Design Limits and Best-Fit Uses for REC Group REC610AA Pro MG?
Evaluate REC Group REC610AA Pro MG (610.0 W STC, 44.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC610AA Pro MG reaches 49.04 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of REC Group REC610AA Pro MG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
REC Group REC610AA Pro MG 8 kW Residential Fit
Needs 14 modules (417 sq ft) with a 30 A string OCPD, offsetting ~$2,137/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare KOSOL ENERGIE PVT LTD KE-620-66XU.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 581.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for REC Group REC610AA Pro MG by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.
How many REC Group REC610AA Pro MG panels fit on a 600 V winter solar string?
At -10 C (14 F), REC Group REC610AA Pro MG cold Voc rises from 44.4 V to 48.01 V (beta_Voc -0.232%/C), capping a 600 V string at 12 panels (576.1 V).
How much roof area does an 8 kW array of REC Group REC610AA Pro MG need?
An 8 kW DC system uses 14 REC Group REC610AA Pro MG modules (8,540 W STC / 8,141 W PTC), covering roughly 417 sq ft and saving ~$2,137/yr at 18.54 c/kWh.
How does REC Group REC610AA Pro MG compare against KOSOL ENERGIE PVT LTD KE-620-66XU?
REC Group REC610AA Pro MG outputs 610.0 W STC (44.4 V Voc, rank #1,104 of 21,677), while KOSOL ENERGIE PVT LTD KE-620-66XU delivers 620.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)