Skip to main content
WireAndSun
Calculators
CEC PV Module

REC Group REC450AA 72 XV — CEC Solar Module Specifications

Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC450AA 72 XV is a 450.0 W STC (427.0 W PTC) Mono-c-Si solar module ranking #5,679 of 21,677 CEC listings (top 27.8%; higher than 72.2% of peers). It delivers 21.9% efficiency, 53.2 V Voc at 25 C, and 57.58 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
450.0 W
PTC Wattage
427.0 W
Voc @ 25C
53.2 V
Efficiency
21.9%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC450AA 72 XV Compare Against Peer CEC Listings?

Solar engineering breakdown for REC Group REC450AA 72 XV: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from REC Group and peers, REC Group REC450AA 72 XV stands 40.0 W above the 410.0 W Mono-c-Si median and strong 94.9% PTC-to-STC heat retention (#1,466 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,577-$2,591/yr in baseline US bill offset. Higher 53.2 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does REC Group REC450AA 72 XV Fall Across Listed CEC Models?

Distribution marker showing REC Group REC450AA 72 XV (450.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC450AA 72 XV (450.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC450AA: 450.0 W

What Dataset Percentiles Define REC Group REC450AA 72 XV?

Dataset percentiles tracking REC Group REC450AA 72 XV power output, thermal retention ratio, and aperture efficiency against 21,677 models.

REC Group REC450AA 72 XV Engineering BenchmarksPercentile comparison of REC Group REC450AA 72 XV wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage450.0 WPTC/STC Retention94.9%Module Efficiency21.9%

What Do the Dataset Ranks Show for REC Group REC450AA 72 XV?

Benchmark highlights for REC Group REC450AA 72 XV covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #5,679 / 21,677

Top 27.8% STC Output

450.0 W STC (+65.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,316

21.9% Aperture Efficiency

Power density 219.0 W/m2 (1.99 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.58 V at -10 C (575.8 V string) and 58.83 V at -20 C (10 max).

8 kW Reference Array

18 Panels = 8,100 W STC

Occupies 37.0 m2 (398 sq ft) producing 7,686 W PTC; NEC 690.8 OCPD floor is 16.27 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 53.2 * (1 + (-0.235/100) * (-10 - 25)) = 57.58 V | OCPD = 1.56 * 10.43 = 16.27 A

Inputs from CEC Modules.csv for REC Group REC450AA 72 XV: Voc=53.2 V, beta_Voc=-0.235%/C, Isc=10.43 A, STC=450.0 W, Area=2.055 m2.

Result: 10 panels max on 600 V (575.8 V); 18 panels for 8 kW (398 sq ft).

What Are the Published CEC Specifications for REC Group REC450AA 72 XV?

Official CEC datasheet figures for REC Group REC450AA 72 XV (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC450AA 72 XV.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 450.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 427.0 W (94.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 53.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.43 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 46.3 V / 9.72 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.235 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.9% (2.055 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC450AA 72 XV Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many REC Group REC450AA 72 XV modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.3 kW 310 sq ft $1,577 $2,666
8 kW Class 18 8.1 kW 398 sq ft $2,027 $3,428
10 kW Class 23 10.35 kW 509 sq ft $2,591 $4,380

How Many REC Group REC450AA 72 XV Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on REC Group REC450AA 72 XV (57.58 V at 14 F).

Computed from Voc=53.2V and beta_Voc=-0.235%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 58.83 V 10 panels 588.3 V 16 panels
-10 C (14 F) 57.58 V 10 panels 575.8 V 17 panels
0 C (32 F) 56.33 V 10 panels 563.3 V 17 panels
25 C (77 F STC) 53.2 V 11 panels 585.2 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC450AA 72 XV?

Competing CEC solar panels closest to REC Group REC450AA 72 XV in nameplate wattage and Voc, starting with Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
450.0 W Tie (0 W) 50.0 V 21.23% 92.5%
AXITEC AC-450MH/144V
AXITEC
450.0 W Tie (0 W) 50.0 V 21.23% 92.5%
Dehui Solar Power (Vietnam) CoLtd DH-M772W 450W
Dehui Solar Power (Vietnam) CoLtd
450.0 W Tie (0 W) 50.0 V 21.23% 92.5%
FreeVolt ECP-PVGRAF-144HC-450W
FreeVolt
450.0 W Tie (0 W) 50.0 V 21.23% 92.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC450AA 72 XV?

Evaluate REC Group REC450AA 72 XV (450.0 W STC, 53.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC450AA 72 XV reaches 58.83 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 398 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (398 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of REC Group REC450AA 72 XV carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC450AA 72 XV 8 kW Residential Fit

Needs 18 modules (398 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-450W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 427.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC450AA 72 XV by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for REC Group REC450AA 72 XV?

Multiplying REC Group REC450AA 72 XV's 10.43 A short-circuit current by 1.56 equals 16.27 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can REC Group REC450AA 72 XV pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 57.58 V cold Voc at 14 F and handles 10.43 A Isc; string inverters cap REC Group REC450AA 72 XV at 10 panels on 600 V.

Is REC Group REC450AA 72 XV eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC450AA 72 XV rely on utility bill offset (~$2,027/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.