Skip to main content
WireAndSun
Calculators
CEC PV Module

REC Group REC445AA Pure-RX-DC — CEC Solar Module Specifications

Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC445AA Pure-RX-DC is a 445.0 W STC (424.2 W PTC) Mono-c-Si solar module ranking #6,028 of 21,677 CEC listings (top 29.6%; higher than 70.4% of peers). It delivers 22.03% efficiency, 65.6 V Voc at 25 C, and 70.95 V cold Voc at -10 C (8 panels max per 600 V string).

STC Wattage
445.0 W
PTC Wattage
424.2 W
Voc @ 25C
65.6 V
Efficiency
22.03%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC445AA Pure-RX-DC Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for REC Group REC445AA Pure-RX-DC (Mono-c-Si) residential solar systems.

REC Group REC445AA Pure-RX-DC delivers 220.3 W/m2 (2.12 percentage points above 19.91% CEC median) and strong 95.3% PTC-to-STC heat retention (#237 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 18 panels (391 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 72.48 V per unit, capping 600 V circuits at 8 panels. Compare specs directly with CSI Solar Co Ltd CS3Y-445P (445.0 W).

Where Does REC Group REC445AA Pure-RX-DC Fall Across Listed CEC Models?

Comparison of REC Group REC445AA Pure-RX-DC (445.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC445AA Pure-RX-DC (445.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC445AA: 445.0 W

What Dataset Percentiles Define REC Group REC445AA Pure-RX-DC?

Relative ranking of REC Group REC445AA Pure-RX-DC across nameplate watts, 95.3% PTC thermal ratio, and module aperture efficiency.

REC Group REC445AA Pure-RX-DC Engineering BenchmarksPercentile comparison of REC Group REC445AA Pure-RX-DC wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage445.0 WPTC/STC Retention95.3%Module Efficiency22.03%

What Do the Dataset Ranks Show for REC Group REC445AA Pure-RX-DC?

Summary of REC Group REC445AA Pure-RX-DC output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.

Rank #6,028 / 21,677

Top 29.6% STC Output

445.0 W STC (+60.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,050

22.03% Aperture Efficiency

Power density 220.3 W/m2 (2.12 percentage points above 19.91% CEC median). PTC/STC ratio: 95.3% (rank #237).

NEC 690.7 Limit

8 Panels Max @ -10 C (600 V)

Cold Voc reaches 70.95 V at -10 C (567.6 V string) and 72.48 V at -20 C (8 max).

8 kW Reference Array

18 Panels = 8,010 W STC

Occupies 36.4 m2 (391 sq ft) producing 7,636 W PTC; NEC 690.8 OCPD floor is 13.68 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 65.6 * (1 + (-0.233/100) * (-10 - 25)) = 70.95 V | OCPD = 1.56 * 8.77 = 13.68 A

Inputs from CEC Modules.csv for REC Group REC445AA Pure-RX-DC: Voc=65.6 V, beta_Voc=-0.233%/C, Isc=8.77 A, STC=445.0 W, Area=2.02 m2.

Result: 8 panels max on 600 V (567.6 V); 18 panels for 8 kW (391 sq ft).

What Are the Published CEC Specifications for REC Group REC445AA Pure-RX-DC?

Complete CEC test sheet for REC Group REC445AA Pure-RX-DC including Isc (8.77 A), Voc (65.6 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC445AA Pure-RX-DC.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 445.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 424.2 W (95.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 65.6 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.77 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 54.0 V / 8.25 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.233 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.03% (2.02 m2) Array roof footprint density
Cell Count & Technology 88 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC445AA Pure-RX-DC Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using REC Group REC445AA Pure-RX-DC.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.23 kW 304 sq ft $1,559 $2,637
8 kW Class 18 8.01 kW 391 sq ft $2,005 $3,390
10 kW Class 23 10.23 kW 500 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Related REC Group power steps and black/silver trims consolidated into this REC Group REC445AA Pure-RX-DC series guide.

Sibling CEC listings grouped into the REC Group REC445AA Pure-RX-DC wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
REC Group REC440AA Pure-RX-DC 440.0 W 419.4 W 65.6 V 53.7 V 21.78%
REC Group REC445AA Pure-RX-DC 445.0 W 424.2 W 65.6 V 54.0 V 22.03%

How Many REC Group REC445AA Pure-RX-DC Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for REC Group REC445AA Pure-RX-DC (65.6 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=65.6V and beta_Voc=-0.233%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 72.48 V 8 panels 579.8 V 13 panels
-10 C (14 F) 70.95 V 8 panels 567.6 V 14 panels
0 C (32 F) 69.42 V 8 panels 555.4 V 14 panels
25 C (77 F STC) 65.6 V 9 panels 590.4 V 15 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC445AA Pure-RX-DC?

Four comparable CEC modules such as CSI Solar Co Ltd CS3Y-445P (445.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3Y-445P
CSI Solar Co Ltd
445.0 W Tie (0 W) 51.4 V 19.43% 93.0%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
440.0 W -5.0 W 49.6 V 20.75% 92.4%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-440W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
440.0 W -5.0 W 49.3 V 20.56% 92.6%
Apollo Renewables Inc Apollo-M672BH-440TW
Apollo Renewables Inc
440.0 W -5.0 W 49.2 V 20.47% 93.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC445AA Pure-RX-DC?

Evaluate REC Group REC445AA Pure-RX-DC (445.0 W STC, 65.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC445AA Pure-RX-DC reaches 72.48 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 391 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (391 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of REC Group REC445AA Pure-RX-DC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC445AA Pure-RX-DC 8 kW Residential Fit

Needs 18 modules (391 sq ft) with a 15 A string OCPD, offsetting ~$2,005/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-445P.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 424.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC445AA Pure-RX-DC by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

How many REC Group REC445AA Pure-RX-DC panels fit on a 600 V winter solar string?

At -10 C (14 F), REC Group REC445AA Pure-RX-DC cold Voc rises from 65.6 V to 70.95 V (beta_Voc -0.233%/C), capping a 600 V string at 8 panels (567.6 V).

How much roof area does an 8 kW array of REC Group REC445AA Pure-RX-DC need?

An 8 kW DC system uses 18 REC Group REC445AA Pure-RX-DC modules (8,010 W STC / 7,636 W PTC), covering roughly 391 sq ft and saving ~$2,005/yr at 18.54 c/kWh.

How does REC Group REC445AA Pure-RX-DC compare against CSI Solar Co Ltd CS3Y-445P?

REC Group REC445AA Pure-RX-DC outputs 445.0 W STC (65.6 V Voc, rank #6,028 of 21,677), while CSI Solar Co Ltd CS3Y-445P delivers 445.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.