REC Group REC445AA Pure-RX-DC is a 445.0 W STC (424.2 W PTC) Mono-c-Si solar module ranking #6,028 of 21,677 CEC listings (top 29.6%; higher than 70.4% of peers). It delivers 22.03% efficiency, 65.6 V Voc at 25 C, and 70.95 V cold Voc at -10 C (8 panels max per 600 V string).
- STC Wattage
- 445.0 W
- PTC Wattage
- 424.2 W
- Voc @ 25C
- 65.6 V
- Efficiency
- 22.03%
How Does REC Group REC445AA Pure-RX-DC Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for REC Group REC445AA Pure-RX-DC (Mono-c-Si) residential solar systems.
REC Group REC445AA Pure-RX-DC delivers 220.3 W/m2 (2.12 percentage points above 19.91% CEC median) and strong 95.3% PTC-to-STC heat retention (#237 of 21,677), placing it as a modern high-density residential and light-commercial module well-proportioned for residential pitched roofs needing 18 panels (391 sq ft) for an 8 kW array. At -4 F (-20 C), string voltage climbs to 72.48 V per unit, capping 600 V circuits at 8 panels. Compare specs directly with CSI Solar Co Ltd CS3Y-445P (445.0 W).
Where Does REC Group REC445AA Pure-RX-DC Fall Across Listed CEC Models?
Comparison of REC Group REC445AA Pure-RX-DC (445.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define REC Group REC445AA Pure-RX-DC?
Relative ranking of REC Group REC445AA Pure-RX-DC across nameplate watts, 95.3% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for REC Group REC445AA Pure-RX-DC?
Summary of REC Group REC445AA Pure-RX-DC output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.
Top 29.6% STC Output
445.0 W STC (+60.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.03% Aperture Efficiency
Power density 220.3 W/m2 (2.12 percentage points above 19.91% CEC median). PTC/STC ratio: 95.3% (rank #237).
8 Panels Max @ -10 C (600 V)
Cold Voc reaches 70.95 V at -10 C (567.6 V string) and 72.48 V at -20 C (8 max).
18 Panels = 8,010 W STC
Occupies 36.4 m2 (391 sq ft) producing 7,636 W PTC; NEC 690.8 OCPD floor is 13.68 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 65.6 * (1 + (-0.233/100) * (-10 - 25)) = 70.95 V | OCPD = 1.56 * 8.77 = 13.68 A
Inputs from CEC Modules.csv for REC Group REC445AA Pure-RX-DC: Voc=65.6 V, beta_Voc=-0.233%/C, Isc=8.77 A, STC=445.0 W, Area=2.02 m2.
Result: 8 panels max on 600 V (567.6 V); 18 panels for 8 kW (391 sq ft).
What Are the Published CEC Specifications for REC Group REC445AA Pure-RX-DC?
Complete CEC test sheet for REC Group REC445AA Pure-RX-DC including Isc (8.77 A), Voc (65.6 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 445.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 424.2 W (95.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 65.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.77 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 54.0 V / 8.25 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.233 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.03% (2.02 m2) | Array roof footprint density |
| Cell Count & Technology | 88 cells (Mono-c-Si) | Monofacial backsheet |
How Many REC Group REC445AA Pure-RX-DC Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using REC Group REC445AA Pure-RX-DC.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.23 kW | 304 sq ft | $1,559 | $2,637 |
| 8 kW Class | 18 | 8.01 kW | 391 sq ft | $2,005 | $3,390 |
| 10 kW Class | 23 | 10.23 kW | 500 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This REC Group Series?
Related REC Group power steps and black/silver trims consolidated into this REC Group REC445AA Pure-RX-DC series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| REC Group REC440AA Pure-RX-DC | 440.0 W | 419.4 W | 65.6 V | 53.7 V | 21.78% |
| REC Group REC445AA Pure-RX-DC | 445.0 W | 424.2 W | 65.6 V | 54.0 V | 22.03% |
How Many REC Group REC445AA Pure-RX-DC Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for REC Group REC445AA Pure-RX-DC (65.6 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 72.48 V | 8 panels | 579.8 V | 13 panels |
| -10 C (14 F) | 70.95 V | 8 panels | 567.6 V | 14 panels |
| 0 C (32 F) | 69.42 V | 8 panels | 555.4 V | 14 panels |
| 25 C (77 F STC) | 65.6 V | 9 panels | 590.4 V | 15 panels |
Which Cross-Brand Solar Modules Compare Closest to REC Group REC445AA Pure-RX-DC?
Four comparable CEC modules such as CSI Solar Co Ltd CS3Y-445P (445.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3Y-445P CSI Solar Co Ltd |
445.0 W | Tie (0 W) | 51.4 V | 19.43% | 93.0% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
440.0 W | -5.0 W | 49.6 V | 20.75% | 92.4% |
| Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-440W Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd |
440.0 W | -5.0 W | 49.3 V | 20.56% | 92.6% |
| Apollo Renewables Inc Apollo-M672BH-440TW Apollo Renewables Inc |
440.0 W | -5.0 W | 49.2 V | 20.47% | 93.4% |
What Are the Design Limits and Best-Fit Uses for REC Group REC445AA Pure-RX-DC?
Evaluate REC Group REC445AA Pure-RX-DC (445.0 W STC, 65.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC445AA Pure-RX-DC reaches 72.48 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 391 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (391 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC445AA Pure-RX-DC carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
REC Group REC445AA Pure-RX-DC 8 kW Residential Fit
Needs 18 modules (391 sq ft) with a 15 A string OCPD, offsetting ~$2,005/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-445P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 424.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for REC Group REC445AA Pure-RX-DC by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.
How many REC Group REC445AA Pure-RX-DC panels fit on a 600 V winter solar string?
At -10 C (14 F), REC Group REC445AA Pure-RX-DC cold Voc rises from 65.6 V to 70.95 V (beta_Voc -0.233%/C), capping a 600 V string at 8 panels (567.6 V).
How much roof area does an 8 kW array of REC Group REC445AA Pure-RX-DC need?
An 8 kW DC system uses 18 REC Group REC445AA Pure-RX-DC modules (8,010 W STC / 7,636 W PTC), covering roughly 391 sq ft and saving ~$2,005/yr at 18.54 c/kWh.
How does REC Group REC445AA Pure-RX-DC compare against CSI Solar Co Ltd CS3Y-445P?
REC Group REC445AA Pure-RX-DC outputs 445.0 W STC (65.6 V Voc, rank #6,028 of 21,677), while CSI Solar Co Ltd CS3Y-445P delivers 445.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)