Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC440AA Pure-RXG is a 440.0 W STC (420.7 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 21.78% efficiency, 65.4 V Voc at 25 C, and 70.69 V cold Voc at -10 C (8 panels max per 600 V string).

STC Wattage
440.0 W
PTC Wattage
420.7 W
Voc @ 25C
65.4 V
Efficiency
21.78%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC440AA Pure-RXG Compare Against Peer CEC Listings?

Engineering position of REC Group REC440AA Pure-RXG (440.0 W STC) vs. CSI Solar Co Ltd CS3Y-445P across 5,889 CEC Mono-c-Si solar modules.

Built with 44 Mono-c-Si cells, REC Group REC440AA Pure-RXG pairs strong 95.6% PTC-to-STC heat retention (#87 of 21,677) with 65.4 V nominal Voc. An 8 kW residential build (8,360 W DC, 7,993 W PTC) saves ~$2,092/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS3Y-445P offers a 445.0 W alternative.

Where Does REC Group REC440AA Pure-RXG Fall Across Listed CEC Models?

Plots REC Group REC440AA Pure-RXG at 440.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC440AA Pure-RXG (440.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC440AA: 440.0 W

What Dataset Percentiles Define REC Group REC440AA Pure-RXG?

Benchmarks REC Group REC440AA Pure-RXG on STC wattage, thermal PTC/STC retention, and 21.78 aperture conversion efficiency against CEC peers.

REC Group REC440AA Pure-RXG Engineering BenchmarksPercentile comparison of REC Group REC440AA Pure-RXG wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage440.0 WPTC/STC Retention95.6%Module Efficiency21.78%

What Do the Dataset Ranks Show for REC Group REC440AA Pure-RXG?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for REC Group REC440AA Pure-RXG by REC Group.

Rank #6,418 / 21,677

Top 31.6% STC Output

440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,669

21.78% Aperture Efficiency

Power density 217.8 W/m2 (1.87 percentage points above 19.91% CEC median). PTC/STC ratio: 95.6% (rank #87).

NEC 690.7 Limit

8 Panels Max @ -10 C (600 V)

Cold Voc reaches 70.69 V at -10 C (565.5 V string) and 72.2 V at -20 C (8 max).

8 kW Reference Array

19 Panels = 8,360 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,993 W PTC; NEC 690.8 OCPD floor is 13.63 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 65.4 * (1 + (-0.231/100) * (-10 - 25)) = 70.69 V | OCPD = 1.56 * 8.74 = 13.63 A

Inputs from CEC Modules.csv for REC Group REC440AA Pure-RXG: Voc=65.4 V, beta_Voc=-0.231%/C, Isc=8.74 A, STC=440.0 W, Area=2.02 m2.

Result: 8 panels max on 600 V (565.5 V); 19 panels for 8 kW (413 sq ft).

What Are the Published CEC Specifications for REC Group REC440AA Pure-RXG?

Laboratory test ratings recorded for REC Group REC440AA Pure-RXG (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC440AA Pure-RXG.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 440.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 420.7 W (95.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 65.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.74 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 53.7 V / 8.2 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.231 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.78% (2.02 m2) Array roof footprint density
Cell Count & Technology 44 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC440AA Pure-RXG Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (413 sq ft at 8 kW), and estimated Year-1 electric bill offset for REC Group REC440AA Pure-RXG.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.16 kW 304 sq ft $1,542 $2,607
8 kW Class 19 8.36 kW 413 sq ft $2,092 $3,538
10 kW Class 23 10.12 kW 500 sq ft $2,533 $4,283

How Many REC Group REC440AA Pure-RXG Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for REC Group REC440AA Pure-RXG (beta_Voc -0.231%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=65.4V and beta_Voc=-0.231%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 72.2 V 8 panels 577.6 V 13 panels
-10 C (14 F) 70.69 V 8 panels 565.5 V 14 panels
0 C (32 F) 69.18 V 8 panels 553.4 V 14 panels
25 C (77 F STC) 65.4 V 9 panels 588.6 V 15 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC440AA Pure-RXG?

Closest cross-brand CEC competitors to REC Group REC440AA Pure-RXG matched near 440.0 W STC and 65.4 V Voc, led by CSI Solar Co Ltd CS3Y-445P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3Y-445P
CSI Solar Co Ltd
445.0 W +5.0 W 51.4 V 19.43% 93.0%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-HC-440W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
440.0 W Tie (0 W) 49.6 V 20.75% 92.4%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M144-BHC-440W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
440.0 W Tie (0 W) 49.3 V 20.56% 92.6%
Apollo Renewables Inc Apollo-M672BH-440TW
Apollo Renewables Inc
440.0 W Tie (0 W) 49.2 V 20.47% 93.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC440AA Pure-RXG?

Evaluate REC Group REC440AA Pure-RXG (440.0 W STC, 65.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC440AA Pure-RXG reaches 72.2 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 413 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (413 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of REC Group REC440AA Pure-RXG carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC440AA Pure-RXG 8 kW Residential Fit

Needs 19 modules (413 sq ft) with a 15 A string OCPD, offsetting ~$2,092/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-445P.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 420.7 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC440AA Pure-RXG by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for REC Group REC440AA Pure-RXG?

Multiplying REC Group REC440AA Pure-RXG's 8.74 A short-circuit current by 1.56 equals 13.63 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can REC Group REC440AA Pure-RXG pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 70.69 V cold Voc at 14 F and handles 8.74 A Isc; string inverters cap REC Group REC440AA Pure-RXG at 8 panels on 600 V.

Is REC Group REC440AA Pure-RXG eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC440AA Pure-RXG rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.