REC Group REC435AA 72 is a 435.0 W STC (412.4 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 21.12% efficiency, 52.9 V Voc at 25 C, and 57.25 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 435.0 W
- PTC Wattage
- 412.4 W
- Voc @ 25C
- 52.9 V
- Efficiency
- 21.12%
How Does REC Group REC435AA 72 Compare Against Peer CEC Listings?
Solar engineering breakdown for REC Group REC435AA 72: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from REC Group and peers, REC Group REC435AA 72 stands 25.0 W above the 410.0 W Mono-c-Si median and strong 94.8% PTC-to-STC heat retention (#1,790 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,524-$2,505/yr in baseline US bill offset. Higher 52.9 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does REC Group REC435AA 72 Fall Across Listed CEC Models?
Distribution marker showing REC Group REC435AA 72 (435.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define REC Group REC435AA 72?
Dataset percentiles tracking REC Group REC435AA 72 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for REC Group REC435AA 72?
Benchmark highlights for REC Group REC435AA 72 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 33.5% STC Output
435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.12% Aperture Efficiency
Power density 211.2 W/m2 (1.21 percentage points above 19.91% CEC median). PTC/STC ratio: 94.8% (rank #1,790).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 57.25 V at -10 C (572.5 V string) and 58.49 V at -20 C (10 max).
19 Panels = 8,265 W STC
Occupies 39.1 m2 (421 sq ft) producing 7,836 W PTC; NEC 690.8 OCPD floor is 16.02 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 52.9 * (1 + (-0.235/100) * (-10 - 25)) = 57.25 V | OCPD = 1.56 * 10.27 = 16.02 A
Inputs from CEC Modules.csv for REC Group REC435AA 72: Voc=52.9 V, beta_Voc=-0.235%/C, Isc=10.27 A, STC=435.0 W, Area=2.06 m2.
Result: 10 panels max on 600 V (572.5 V); 19 panels for 8 kW (421 sq ft).
What Are the Published CEC Specifications for REC Group REC435AA 72?
Official CEC datasheet figures for REC Group REC435AA 72 (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 435.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 412.4 W (94.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 52.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.27 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 45.4 V / 9.59 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.235 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.12% (2.06 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many REC Group REC435AA 72 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many REC Group REC435AA 72 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.09 kW | 310 sq ft | $1,524 | $2,577 |
| 8 kW Class | 19 | 8.27 kW | 421 sq ft | $2,070 | $3,500 |
| 10 kW Class | 23 | 10.01 kW | 510 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This REC Group Series?
Consolidated REC Group wattage variants sharing the REC Group REC435AA 72 mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| REC Group REC425AA 72 | 425.0 W | 402.8 W | 52.6 V | 44.8 V | 20.63% |
| REC Group REC430AA 72 | 430.0 W | 407.6 W | 52.7 V | 45.1 V | 20.87% |
| REC Group REC435AA 72 | 435.0 W | 412.4 W | 52.9 V | 45.4 V | 21.12% |
| REC Group REC440AA 72 | 440.0 W | 417.3 W | 53.0 V | 45.7 V | 21.36% |
| REC Group REC445AA 72 | 445.0 W | 422.1 W | 53.2 V | 46.0 V | 21.6% |
How Many REC Group REC435AA 72 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on REC Group REC435AA 72 (57.25 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 58.49 V | 10 panels | 584.9 V | 17 panels |
| -10 C (14 F) | 57.25 V | 10 panels | 572.5 V | 17 panels |
| 0 C (32 F) | 56.01 V | 10 panels | 560.1 V | 17 panels |
| 25 C (77 F STC) | 52.9 V | 11 panels | 581.9 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to REC Group REC435AA 72?
Competing CEC solar panels closest to REC Group REC435AA 72 in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-144-MF26-435W {Blk} Aptos Solar Technology LLC |
435.0 W | Tie (0 W) | 49.7 V | 20.71% | 91.8% |
| Aptos Solar Technology LLC DNA-144-MF26-435W {Wht} Aptos Solar Technology LLC |
435.0 W | Tie (0 W) | 49.7 V | 20.71% | 92.8% |
| CertainTeed CT435HC11-06 CertainTeed |
435.0 W | Tie (0 W) | 49.7 V | 20.71% | 91.8% |
| AXITEC AC-435MH/144V AXITEC |
435.0 W | Tie (0 W) | 49.4 V | 20.52% | 92.4% |
What Are the Design Limits and Best-Fit Uses for REC Group REC435AA 72?
Evaluate REC Group REC435AA 72 (435.0 W STC, 52.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC435AA 72 reaches 58.49 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 421 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (421 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC435AA 72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
REC Group REC435AA 72 8 kW Residential Fit
Needs 19 modules (421 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 412.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for REC Group REC435AA 72 by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for REC Group REC435AA 72?
Multiplying REC Group REC435AA 72's 10.27 A short-circuit current by 1.56 equals 16.02 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can REC Group REC435AA 72 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 57.25 V cold Voc at 14 F and handles 10.27 A Isc; string inverters cap REC Group REC435AA 72 at 10 panels on 600 V.
Is REC Group REC435AA 72 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC435AA 72 rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)