Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC435AA 72 is a 435.0 W STC (412.4 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 21.12% efficiency, 52.9 V Voc at 25 C, and 57.25 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
435.0 W
PTC Wattage
412.4 W
Voc @ 25C
52.9 V
Efficiency
21.12%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC435AA 72 Compare Against Peer CEC Listings?

Solar engineering breakdown for REC Group REC435AA 72: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from REC Group and peers, REC Group REC435AA 72 stands 25.0 W above the 410.0 W Mono-c-Si median and strong 94.8% PTC-to-STC heat retention (#1,790 of 21,677). Sizing 6 kW (14 panels) to 10 kW (23 panels) yields $1,524-$2,505/yr in baseline US bill offset. Higher 52.9 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).

Where Does REC Group REC435AA 72 Fall Across Listed CEC Models?

Distribution marker showing REC Group REC435AA 72 (435.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC435AA 72 (435.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC435AA: 435.0 W

What Dataset Percentiles Define REC Group REC435AA 72?

Dataset percentiles tracking REC Group REC435AA 72 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

REC Group REC435AA 72 Engineering BenchmarksPercentile comparison of REC Group REC435AA 72 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage435.0 WPTC/STC Retention94.8%Module Efficiency21.12%

What Do the Dataset Ranks Show for REC Group REC435AA 72?

Benchmark highlights for REC Group REC435AA 72 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #6,850 / 21,677

Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,831

21.12% Aperture Efficiency

Power density 211.2 W/m2 (1.21 percentage points above 19.91% CEC median). PTC/STC ratio: 94.8% (rank #1,790).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.25 V at -10 C (572.5 V string) and 58.49 V at -20 C (10 max).

8 kW Reference Array

19 Panels = 8,265 W STC

Occupies 39.1 m2 (421 sq ft) producing 7,836 W PTC; NEC 690.8 OCPD floor is 16.02 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.9 * (1 + (-0.235/100) * (-10 - 25)) = 57.25 V | OCPD = 1.56 * 10.27 = 16.02 A

Inputs from CEC Modules.csv for REC Group REC435AA 72: Voc=52.9 V, beta_Voc=-0.235%/C, Isc=10.27 A, STC=435.0 W, Area=2.06 m2.

Result: 10 panels max on 600 V (572.5 V); 19 panels for 8 kW (421 sq ft).

What Are the Published CEC Specifications for REC Group REC435AA 72?

Official CEC datasheet figures for REC Group REC435AA 72 (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC435AA 72.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 435.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 412.4 W (94.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 52.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.27 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 45.4 V / 9.59 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.235 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.12% (2.06 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC435AA 72 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many REC Group REC435AA 72 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.09 kW 310 sq ft $1,524 $2,577
8 kW Class 19 8.27 kW 421 sq ft $2,070 $3,500
10 kW Class 23 10.01 kW 510 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Consolidated REC Group wattage variants sharing the REC Group REC435AA 72 mechanical and cell layout. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Sibling CEC listings grouped into the REC Group REC435AA 72 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
REC Group REC425AA 72 425.0 W 402.8 W 52.6 V 44.8 V 20.63%
REC Group REC430AA 72 430.0 W 407.6 W 52.7 V 45.1 V 20.87%
REC Group REC435AA 72 435.0 W 412.4 W 52.9 V 45.4 V 21.12%
REC Group REC440AA 72 440.0 W 417.3 W 53.0 V 45.7 V 21.36%
REC Group REC445AA 72 445.0 W 422.1 W 53.2 V 46.0 V 21.6%

How Many REC Group REC435AA 72 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on REC Group REC435AA 72 (57.25 V at 14 F).

Computed from Voc=52.9V and beta_Voc=-0.235%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 58.49 V 10 panels 584.9 V 17 panels
-10 C (14 F) 57.25 V 10 panels 572.5 V 17 panels
0 C (32 F) 56.01 V 10 panels 560.1 V 17 panels
25 C (77 F STC) 52.9 V 11 panels 581.9 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC435AA 72?

Competing CEC solar panels closest to REC Group REC435AA 72 in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}
Aptos Solar Technology LLC
435.0 W Tie (0 W) 49.7 V 20.71% 91.8%
Aptos Solar Technology LLC DNA-144-MF26-435W {Wht}
Aptos Solar Technology LLC
435.0 W Tie (0 W) 49.7 V 20.71% 92.8%
CertainTeed CT435HC11-06
CertainTeed
435.0 W Tie (0 W) 49.7 V 20.71% 91.8%
AXITEC AC-435MH/144V
AXITEC
435.0 W Tie (0 W) 49.4 V 20.52% 92.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC435AA 72?

Evaluate REC Group REC435AA 72 (435.0 W STC, 52.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC435AA 72 reaches 58.49 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 421 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (421 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of REC Group REC435AA 72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC435AA 72 8 kW Residential Fit

Needs 19 modules (421 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 412.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC435AA 72 by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for REC Group REC435AA 72?

Multiplying REC Group REC435AA 72's 10.27 A short-circuit current by 1.56 equals 16.02 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can REC Group REC435AA 72 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 57.25 V cold Voc at 14 F and handles 10.27 A Isc; string inverters cap REC Group REC435AA 72 at 10 panels on 600 V.

Is REC Group REC435AA 72 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC435AA 72 rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.