Skip to main content
WireAndSun
Calculators
CEC PV Module

REC Group REC435AA 72 XV — CEC Solar Module Specifications

Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC435AA 72 XV is a 435.0 W STC (412.4 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 21.12% efficiency, 52.9 V Voc at 25 C, and 57.25 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
435.0 W
PTC Wattage
412.4 W
Voc @ 25C
52.9 V
Efficiency
21.12%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC435AA 72 XV Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for REC Group REC435AA 72 XV (Mono-c-Si) residential solar systems.

Homeowners evaluating REC Group REC435AA 72 XV need 14 panels for 6 kW or 19 panels (421 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 19 panels (421 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.235%/C) pushes open-circuit voltage to 57.25 V at 14 F and 58.49 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does REC Group REC435AA 72 XV Fall Across Listed CEC Models?

Comparison of REC Group REC435AA 72 XV (435.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC435AA 72 XV (435.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC435AA: 435.0 W

What Dataset Percentiles Define REC Group REC435AA 72 XV?

Relative ranking of REC Group REC435AA 72 XV across nameplate watts, 94.8% PTC thermal ratio, and module aperture efficiency.

REC Group REC435AA 72 XV Engineering BenchmarksPercentile comparison of REC Group REC435AA 72 XV wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage435.0 WPTC/STC Retention94.8%Module Efficiency21.12%

What Do the Dataset Ranks Show for REC Group REC435AA 72 XV?

Summary of REC Group REC435AA 72 XV output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.

Rank #6,850 / 21,677

Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,831

21.12% Aperture Efficiency

Power density 211.2 W/m2 (1.21 percentage points above 19.91% CEC median). PTC/STC ratio: 94.8% (rank #1,790).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 57.25 V at -10 C (572.5 V string) and 58.49 V at -20 C (10 max).

8 kW Reference Array

19 Panels = 8,265 W STC

Occupies 39.1 m2 (421 sq ft) producing 7,836 W PTC; NEC 690.8 OCPD floor is 16.02 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.9 * (1 + (-0.235/100) * (-10 - 25)) = 57.25 V | OCPD = 1.56 * 10.27 = 16.02 A

Inputs from CEC Modules.csv for REC Group REC435AA 72 XV: Voc=52.9 V, beta_Voc=-0.235%/C, Isc=10.27 A, STC=435.0 W, Area=2.06 m2.

Result: 10 panels max on 600 V (572.5 V); 19 panels for 8 kW (421 sq ft).

What Are the Published CEC Specifications for REC Group REC435AA 72 XV?

Complete CEC test sheet for REC Group REC435AA 72 XV including Isc (10.27 A), Voc (52.9 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC435AA 72 XV.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 435.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 412.4 W (94.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 52.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.27 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 45.4 V / 9.59 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.235 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.12% (2.06 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC435AA 72 XV Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using REC Group REC435AA 72 XV.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.09 kW 310 sq ft $1,524 $2,577
8 kW Class 19 8.27 kW 421 sq ft $2,070 $3,500
10 kW Class 23 10.01 kW 510 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

Related REC Group power steps and black/silver trims consolidated into this REC Group REC435AA 72 XV series guide.

Sibling CEC listings grouped into the REC Group REC435AA 72 XV wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
REC Group REC425AA 72 XV 425.0 W 402.8 W 52.6 V 44.8 V 20.63%
REC Group REC430AA 72 XV 430.0 W 407.6 W 52.7 V 45.1 V 20.92%
REC Group REC435AA 72 XV 435.0 W 412.4 W 52.9 V 45.4 V 21.12%
REC Group REC440AA 72 XV 440.0 W 417.3 W 53.0 V 45.7 V 21.36%
REC Group REC445AA 72 XV 445.0 W 422.1 W 53.2 V 46.0 V 21.6%

How Many REC Group REC435AA 72 XV Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for REC Group REC435AA 72 XV (52.9 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=52.9V and beta_Voc=-0.235%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 58.49 V 10 panels 584.9 V 17 panels
-10 C (14 F) 57.25 V 10 panels 572.5 V 17 panels
0 C (32 F) 56.01 V 10 panels 560.1 V 17 panels
25 C (77 F STC) 52.9 V 11 panels 581.9 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC435AA 72 XV?

Four comparable CEC modules such as Aptos Solar Technology LLC DNA-144-MF26-435W {Blk} (435.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}
Aptos Solar Technology LLC
435.0 W Tie (0 W) 49.7 V 20.71% 91.8%
Aptos Solar Technology LLC DNA-144-MF26-435W {Wht}
Aptos Solar Technology LLC
435.0 W Tie (0 W) 49.7 V 20.71% 92.8%
CertainTeed CT435HC11-06
CertainTeed
435.0 W Tie (0 W) 49.7 V 20.71% 91.8%
AXITEC AC-435MH/144V
AXITEC
435.0 W Tie (0 W) 49.4 V 20.52% 92.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC435AA 72 XV?

Evaluate REC Group REC435AA 72 XV (435.0 W STC, 52.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC435AA 72 XV reaches 58.49 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 421 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (421 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of REC Group REC435AA 72 XV carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC435AA 72 XV 8 kW Residential Fit

Needs 19 modules (421 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 412.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC435AA 72 XV by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

Why is REC Group REC435AA 72 XV PTC wattage (412.4 W) lower than STC (435.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 412.4 W PTC (94.8% retention) across REC Group REC435AA 72 XV's 2.06 m2 aperture.

Who should skip REC Group REC435AA 72 XV on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 REC Group REC435AA 72 XV panels (421 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.

What is the 1,000 V commercial string limit for REC Group REC435AA 72 XV?

On 1,000 V commercial inverters at -10 C (57.25 V cold Voc), REC Group REC435AA 72 XV fits up to 17 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.