REC Group REC435AA 72 XV is a 435.0 W STC (412.4 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 21.12% efficiency, 52.9 V Voc at 25 C, and 57.25 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 435.0 W
- PTC Wattage
- 412.4 W
- Voc @ 25C
- 52.9 V
- Efficiency
- 21.12%
How Does REC Group REC435AA 72 XV Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for REC Group REC435AA 72 XV (Mono-c-Si) residential solar systems.
Homeowners evaluating REC Group REC435AA 72 XV need 14 panels for 6 kW or 19 panels (421 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 19 panels (421 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.235%/C) pushes open-circuit voltage to 57.25 V at 14 F and 58.49 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does REC Group REC435AA 72 XV Fall Across Listed CEC Models?
Comparison of REC Group REC435AA 72 XV (435.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define REC Group REC435AA 72 XV?
Relative ranking of REC Group REC435AA 72 XV across nameplate watts, 94.8% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for REC Group REC435AA 72 XV?
Summary of REC Group REC435AA 72 XV output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.
Top 33.5% STC Output
435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.12% Aperture Efficiency
Power density 211.2 W/m2 (1.21 percentage points above 19.91% CEC median). PTC/STC ratio: 94.8% (rank #1,790).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 57.25 V at -10 C (572.5 V string) and 58.49 V at -20 C (10 max).
19 Panels = 8,265 W STC
Occupies 39.1 m2 (421 sq ft) producing 7,836 W PTC; NEC 690.8 OCPD floor is 16.02 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 52.9 * (1 + (-0.235/100) * (-10 - 25)) = 57.25 V | OCPD = 1.56 * 10.27 = 16.02 A
Inputs from CEC Modules.csv for REC Group REC435AA 72 XV: Voc=52.9 V, beta_Voc=-0.235%/C, Isc=10.27 A, STC=435.0 W, Area=2.06 m2.
Result: 10 panels max on 600 V (572.5 V); 19 panels for 8 kW (421 sq ft).
What Are the Published CEC Specifications for REC Group REC435AA 72 XV?
Complete CEC test sheet for REC Group REC435AA 72 XV including Isc (10.27 A), Voc (52.9 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 435.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 412.4 W (94.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 52.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.27 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 45.4 V / 9.59 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.235 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.12% (2.06 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many REC Group REC435AA 72 XV Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using REC Group REC435AA 72 XV.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.09 kW | 310 sq ft | $1,524 | $2,577 |
| 8 kW Class | 19 | 8.27 kW | 421 sq ft | $2,070 | $3,500 |
| 10 kW Class | 23 | 10.01 kW | 510 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This REC Group Series?
Related REC Group power steps and black/silver trims consolidated into this REC Group REC435AA 72 XV series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| REC Group REC425AA 72 XV | 425.0 W | 402.8 W | 52.6 V | 44.8 V | 20.63% |
| REC Group REC430AA 72 XV | 430.0 W | 407.6 W | 52.7 V | 45.1 V | 20.92% |
| REC Group REC435AA 72 XV | 435.0 W | 412.4 W | 52.9 V | 45.4 V | 21.12% |
| REC Group REC440AA 72 XV | 440.0 W | 417.3 W | 53.0 V | 45.7 V | 21.36% |
| REC Group REC445AA 72 XV | 445.0 W | 422.1 W | 53.2 V | 46.0 V | 21.6% |
How Many REC Group REC435AA 72 XV Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for REC Group REC435AA 72 XV (52.9 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 58.49 V | 10 panels | 584.9 V | 17 panels |
| -10 C (14 F) | 57.25 V | 10 panels | 572.5 V | 17 panels |
| 0 C (32 F) | 56.01 V | 10 panels | 560.1 V | 17 panels |
| 25 C (77 F STC) | 52.9 V | 11 panels | 581.9 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to REC Group REC435AA 72 XV?
Four comparable CEC modules such as Aptos Solar Technology LLC DNA-144-MF26-435W {Blk} (435.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-144-MF26-435W {Blk} Aptos Solar Technology LLC |
435.0 W | Tie (0 W) | 49.7 V | 20.71% | 91.8% |
| Aptos Solar Technology LLC DNA-144-MF26-435W {Wht} Aptos Solar Technology LLC |
435.0 W | Tie (0 W) | 49.7 V | 20.71% | 92.8% |
| CertainTeed CT435HC11-06 CertainTeed |
435.0 W | Tie (0 W) | 49.7 V | 20.71% | 91.8% |
| AXITEC AC-435MH/144V AXITEC |
435.0 W | Tie (0 W) | 49.4 V | 20.52% | 92.4% |
What Are the Design Limits and Best-Fit Uses for REC Group REC435AA 72 XV?
Evaluate REC Group REC435AA 72 XV (435.0 W STC, 52.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC435AA 72 XV reaches 58.49 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 421 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (421 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC435AA 72 XV carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
REC Group REC435AA 72 XV 8 kW Residential Fit
Needs 19 modules (421 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 412.4 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for REC Group REC435AA 72 XV by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.
Why is REC Group REC435AA 72 XV PTC wattage (412.4 W) lower than STC (435.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 412.4 W PTC (94.8% retention) across REC Group REC435AA 72 XV's 2.06 m2 aperture.
Who should skip REC Group REC435AA 72 XV on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 REC Group REC435AA 72 XV panels (421 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.
What is the 1,000 V commercial string limit for REC Group REC435AA 72 XV?
On 1,000 V commercial inverters at -10 C (57.25 V cold Voc), REC Group REC435AA 72 XV fits up to 17 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)