REC Group REC420AA 72 is a 420.0 W STC (397.9 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 20.39% efficiency, 52.5 V Voc at 25 C, and 56.82 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 420.0 W
- PTC Wattage
- 397.9 W
- Voc @ 25C
- 52.5 V
- Efficiency
- 20.39%
How Does REC Group REC420AA 72 Compare Against Peer CEC Listings?
How REC Group REC Group REC420AA 72 handles rooftop heat (397.9 W PTC), 8 kW sizing, and cold winter string voltage.
REC Group builds the REC Group REC420AA 72 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 203.9 W/m2 (0.48 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS1Y-410MS (410.0 W), this model holds strong 94.7% PTC-to-STC heat retention (#2,085 of 21,677). Higher 52.5 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 15.91 A overcurrent floor served by a 20 A breaker.
Where Does REC Group REC420AA 72 Fall Across Listed CEC Models?
Where REC Group REC420AA 72 (420.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define REC Group REC420AA 72?
Percentile placement of REC Group REC420AA 72 across power density (203.9 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for REC Group REC420AA 72?
Four critical engineering numbers homeowners and solar installers check first when reviewing REC Group REC420AA 72 specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
Top 37.8% STC Output
420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.39% Aperture Efficiency
Power density 203.9 W/m2 (0.48 percentage points above 19.91% CEC median). PTC/STC ratio: 94.7% (rank #2,085).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 56.82 V at -10 C (568.2 V string) and 58.05 V at -20 C (10 max).
20 Panels = 8,400 W STC
Occupies 41.2 m2 (443 sq ft) producing 7,958 W PTC; NEC 690.8 OCPD floor is 15.91 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 52.5 * (1 + (-0.235/100) * (-10 - 25)) = 56.82 V | OCPD = 1.56 * 10.2 = 15.91 A
Inputs from CEC Modules.csv for REC Group REC420AA 72: Voc=52.5 V, beta_Voc=-0.235%/C, Isc=10.2 A, STC=420.0 W, Area=2.06 m2.
Result: 10 panels max on 600 V (568.2 V); 20 panels for 8 kW (443 sq ft).
What Are the Published CEC Specifications for REC Group REC420AA 72?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for REC Group REC420AA 72.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 397.9 W (94.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 52.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 44.5 V / 9.45 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.235 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.39% (2.06 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many REC Group REC420AA 72 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using REC Group REC420AA 72 (420.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.3 kW | 333 sq ft | $1,577 | $2,666 |
| 8 kW Class | 20 | 8.4 kW | 443 sq ft | $2,102 | $3,555 |
| 10 kW Class | 24 | 10.08 kW | 532 sq ft | $2,523 | $4,266 |
How Many REC Group REC420AA 72 Modules Fit in a Cold-Weather String?
Maximum series module counts for REC Group REC420AA 72 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 58.05 V | 10 panels | 580.5 V | 17 panels |
| -10 C (14 F) | 56.82 V | 10 panels | 568.2 V | 17 panels |
| 0 C (32 F) | 55.58 V | 10 panels | 555.8 V | 17 panels |
| 25 C (77 F STC) | 52.5 V | 11 panels | 577.5 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to REC Group REC420AA 72?
Alternative CEC solar modules from competing brands near REC Group REC420AA 72 (420.0 W), including CSI Solar Co Ltd CS1Y-410MS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS1Y-410MS CSI Solar Co Ltd |
410.0 W | -10.0 W | 52.7 V | 21.03% | 94.1% |
| DualSun SAS DualSun 420M-144-01 DualSun SAS |
420.0 W | Tie (0 W) | 48.8 V | 19.44% | 93.8% |
| Auxin Solar AXNG1M410B Auxin Solar |
410.0 W | -10.0 W | 49.47 V | 20.92% | 93.4% |
| Auxin Solar AXNG1M410W Auxin Solar |
410.0 W | -10.0 W | 49.47 V | 20.92% | 93.3% |
What Are the Design Limits and Best-Fit Uses for REC Group REC420AA 72?
Evaluate REC Group REC420AA 72 (420.0 W STC, 52.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC420AA 72 reaches 58.05 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 443 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (443 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC420AA 72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
REC Group REC420AA 72 8 kW Residential Fit
Needs 20 modules (443 sq ft) with a 20 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-410MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 397.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for REC Group REC420AA 72 by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for REC Group REC420AA 72?
Multiplying REC Group REC420AA 72's 10.2 A short-circuit current by 1.56 equals 15.91 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can REC Group REC420AA 72 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 56.82 V cold Voc at 14 F and handles 10.2 A Isc; string inverters cap REC Group REC420AA 72 at 10 panels on 600 V.
Is REC Group REC420AA 72 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC420AA 72 rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)