Skip to main content
WireAndSun
Calculators
CEC PV Module

REC Group REC420AA 72 — CEC Solar Module Specifications

Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC420AA 72 is a 420.0 W STC (397.9 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 20.39% efficiency, 52.5 V Voc at 25 C, and 56.82 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
420.0 W
PTC Wattage
397.9 W
Voc @ 25C
52.5 V
Efficiency
20.39%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC420AA 72 Compare Against Peer CEC Listings?

How REC Group REC Group REC420AA 72 handles rooftop heat (397.9 W PTC), 8 kW sizing, and cold winter string voltage.

REC Group builds the REC Group REC420AA 72 (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 203.9 W/m2 (0.48 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS1Y-410MS (410.0 W), this model holds strong 94.7% PTC-to-STC heat retention (#2,085 of 21,677). Higher 52.5 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C), while NEC 690.8 sets a 15.91 A overcurrent floor served by a 20 A breaker.

Where Does REC Group REC420AA 72 Fall Across Listed CEC Models?

Where REC Group REC420AA 72 (420.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC420AA 72 (420.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC420AA: 420.0 W

What Dataset Percentiles Define REC Group REC420AA 72?

Percentile placement of REC Group REC420AA 72 across power density (203.9 W/m2), thermal retention, and nameplate STC wattage.

REC Group REC420AA 72 Engineering BenchmarksPercentile comparison of REC Group REC420AA 72 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage420.0 WPTC/STC Retention94.7%Module Efficiency20.39%

What Do the Dataset Ranks Show for REC Group REC420AA 72?

Four critical engineering numbers homeowners and solar installers check first when reviewing REC Group REC420AA 72 specifications. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Rank #7,910 / 21,677

Top 37.8% STC Output

420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,981

20.39% Aperture Efficiency

Power density 203.9 W/m2 (0.48 percentage points above 19.91% CEC median). PTC/STC ratio: 94.7% (rank #2,085).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 56.82 V at -10 C (568.2 V string) and 58.05 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,400 W STC

Occupies 41.2 m2 (443 sq ft) producing 7,958 W PTC; NEC 690.8 OCPD floor is 15.91 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.5 * (1 + (-0.235/100) * (-10 - 25)) = 56.82 V | OCPD = 1.56 * 10.2 = 15.91 A

Inputs from CEC Modules.csv for REC Group REC420AA 72: Voc=52.5 V, beta_Voc=-0.235%/C, Isc=10.2 A, STC=420.0 W, Area=2.06 m2.

Result: 10 panels max on 600 V (568.2 V); 20 panels for 8 kW (443 sq ft).

What Are the Published CEC Specifications for REC Group REC420AA 72?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for REC Group REC420AA 72.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC420AA 72.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 420.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 397.9 W (94.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 52.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.2 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 44.5 V / 9.45 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.235 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.39% (2.06 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC420AA 72 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using REC Group REC420AA 72 (420.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.3 kW 333 sq ft $1,577 $2,666
8 kW Class 20 8.4 kW 443 sq ft $2,102 $3,555
10 kW Class 24 10.08 kW 532 sq ft $2,523 $4,266

How Many REC Group REC420AA 72 Modules Fit in a Cold-Weather String?

Maximum series module counts for REC Group REC420AA 72 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=52.5V and beta_Voc=-0.235%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 58.05 V 10 panels 580.5 V 17 panels
-10 C (14 F) 56.82 V 10 panels 568.2 V 17 panels
0 C (32 F) 55.58 V 10 panels 555.8 V 17 panels
25 C (77 F STC) 52.5 V 11 panels 577.5 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC420AA 72?

Alternative CEC solar modules from competing brands near REC Group REC420AA 72 (420.0 W), including CSI Solar Co Ltd CS1Y-410MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS1Y-410MS
CSI Solar Co Ltd
410.0 W -10.0 W 52.7 V 21.03% 94.1%
DualSun SAS DualSun 420M-144-01
DualSun SAS
420.0 W Tie (0 W) 48.8 V 19.44% 93.8%
Auxin Solar AXNG1M410B
Auxin Solar
410.0 W -10.0 W 49.47 V 20.92% 93.4%
Auxin Solar AXNG1M410W
Auxin Solar
410.0 W -10.0 W 49.47 V 20.92% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC420AA 72?

Evaluate REC Group REC420AA 72 (420.0 W STC, 52.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC420AA 72 reaches 58.05 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 443 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (443 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of REC Group REC420AA 72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC420AA 72 8 kW Residential Fit

Needs 20 modules (443 sq ft) with a 20 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-410MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 397.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC420AA 72 by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for REC Group REC420AA 72?

Multiplying REC Group REC420AA 72's 10.2 A short-circuit current by 1.56 equals 15.91 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can REC Group REC420AA 72 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 56.82 V cold Voc at 14 F and handles 10.2 A Isc; string inverters cap REC Group REC420AA 72 at 10 panels on 600 V.

Is REC Group REC420AA 72 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC420AA 72 rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.