REC Group REC420AA 72 XV is a 420.0 W STC (397.9 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 20.39% efficiency, 52.5 V Voc at 25 C, and 56.82 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 420.0 W
- PTC Wattage
- 397.9 W
- Voc @ 25C
- 52.5 V
- Efficiency
- 20.39%
How Does REC Group REC420AA 72 XV Compare Against Peer CEC Listings?
Engineering position of REC Group REC420AA 72 XV (420.0 W STC) vs. CSI Solar Co Ltd CS1Y-410MS across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, REC Group REC420AA 72 XV pairs strong 94.7% PTC-to-STC heat retention (#2,085 of 21,677) with 52.5 V nominal Voc. An 8 kW residential build (8,400 W DC, 7,958 W PTC) saves ~$2,102/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS1Y-410MS offers a 410.0 W alternative.
Where Does REC Group REC420AA 72 XV Fall Across Listed CEC Models?
Plots REC Group REC420AA 72 XV at 420.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define REC Group REC420AA 72 XV?
Benchmarks REC Group REC420AA 72 XV on STC wattage, thermal PTC/STC retention, and 20.39 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for REC Group REC420AA 72 XV?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for REC Group REC420AA 72 XV by REC Group.
Top 37.8% STC Output
420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.39% Aperture Efficiency
Power density 203.9 W/m2 (0.48 percentage points above 19.91% CEC median). PTC/STC ratio: 94.7% (rank #2,085).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 56.82 V at -10 C (568.2 V string) and 58.05 V at -20 C (10 max).
20 Panels = 8,400 W STC
Occupies 41.2 m2 (443 sq ft) producing 7,958 W PTC; NEC 690.8 OCPD floor is 15.91 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 52.5 * (1 + (-0.235/100) * (-10 - 25)) = 56.82 V | OCPD = 1.56 * 10.2 = 15.91 A
Inputs from CEC Modules.csv for REC Group REC420AA 72 XV: Voc=52.5 V, beta_Voc=-0.235%/C, Isc=10.2 A, STC=420.0 W, Area=2.06 m2.
Result: 10 panels max on 600 V (568.2 V); 20 panels for 8 kW (443 sq ft).
What Are the Published CEC Specifications for REC Group REC420AA 72 XV?
Laboratory test ratings recorded for REC Group REC420AA 72 XV (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 420.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 397.9 W (94.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 52.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 44.5 V / 9.45 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.235 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.39% (2.06 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many REC Group REC420AA 72 XV Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (443 sq ft at 8 kW), and estimated Year-1 electric bill offset for REC Group REC420AA 72 XV.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.3 kW | 333 sq ft | $1,577 | $2,666 |
| 8 kW Class | 20 | 8.4 kW | 443 sq ft | $2,102 | $3,555 |
| 10 kW Class | 24 | 10.08 kW | 532 sq ft | $2,523 | $4,266 |
How Many REC Group REC420AA 72 XV Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for REC Group REC420AA 72 XV (beta_Voc -0.235%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 58.05 V | 10 panels | 580.5 V | 17 panels |
| -10 C (14 F) | 56.82 V | 10 panels | 568.2 V | 17 panels |
| 0 C (32 F) | 55.58 V | 10 panels | 555.8 V | 17 panels |
| 25 C (77 F STC) | 52.5 V | 11 panels | 577.5 V | 19 panels |
Which Cross-Brand Solar Modules Compare Closest to REC Group REC420AA 72 XV?
Closest cross-brand CEC competitors to REC Group REC420AA 72 XV matched near 420.0 W STC and 52.5 V Voc, led by CSI Solar Co Ltd CS1Y-410MS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS1Y-410MS CSI Solar Co Ltd |
410.0 W | -10.0 W | 52.7 V | 21.03% | 94.1% |
| DualSun SAS DualSun 420M-144-01 DualSun SAS |
420.0 W | Tie (0 W) | 48.8 V | 19.44% | 93.8% |
| Auxin Solar AXNG1M410B Auxin Solar |
410.0 W | -10.0 W | 49.47 V | 20.92% | 93.4% |
| Auxin Solar AXNG1M410W Auxin Solar |
410.0 W | -10.0 W | 49.47 V | 20.92% | 93.3% |
What Are the Design Limits and Best-Fit Uses for REC Group REC420AA 72 XV?
Evaluate REC Group REC420AA 72 XV (420.0 W STC, 52.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC420AA 72 XV reaches 58.05 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 20 panels for an 8 kW build require 443 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (443 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of REC Group REC420AA 72 XV carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
REC Group REC420AA 72 XV 8 kW Residential Fit
Needs 20 modules (443 sq ft) with a 20 A string OCPD, offsetting ~$2,102/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-410MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 397.9 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for REC Group REC420AA 72 XV by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for REC Group REC420AA 72 XV?
Multiplying REC Group REC420AA 72 XV's 10.2 A short-circuit current by 1.56 equals 15.91 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can REC Group REC420AA 72 XV pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 56.82 V cold Voc at 14 F and handles 10.2 A Isc; string inverters cap REC Group REC420AA 72 XV at 10 panels on 600 V.
Is REC Group REC420AA 72 XV eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC420AA 72 XV rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)