Skip to main content
WireAndSun
Calculators
CEC PV Module

REC Group REC420AA 72 XV — CEC Solar Module Specifications

Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC420AA 72 XV is a 420.0 W STC (397.9 W PTC) Mono-c-Si solar module ranking #7,910 of 21,677 CEC listings (top 37.8%; higher than 62.2% of peers). It delivers 20.39% efficiency, 52.5 V Voc at 25 C, and 56.82 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
420.0 W
PTC Wattage
397.9 W
Voc @ 25C
52.5 V
Efficiency
20.39%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC420AA 72 XV Compare Against Peer CEC Listings?

Engineering position of REC Group REC420AA 72 XV (420.0 W STC) vs. CSI Solar Co Ltd CS1Y-410MS across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, REC Group REC420AA 72 XV pairs strong 94.7% PTC-to-STC heat retention (#2,085 of 21,677) with 52.5 V nominal Voc. An 8 kW residential build (8,400 W DC, 7,958 W PTC) saves ~$2,102/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS1Y-410MS offers a 410.0 W alternative.

Where Does REC Group REC420AA 72 XV Fall Across Listed CEC Models?

Plots REC Group REC420AA 72 XV at 420.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC420AA 72 XV (420.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC420AA: 420.0 W

What Dataset Percentiles Define REC Group REC420AA 72 XV?

Benchmarks REC Group REC420AA 72 XV on STC wattage, thermal PTC/STC retention, and 20.39 aperture conversion efficiency against CEC peers.

REC Group REC420AA 72 XV Engineering BenchmarksPercentile comparison of REC Group REC420AA 72 XV wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage420.0 WPTC/STC Retention94.7%Module Efficiency20.39%

What Do the Dataset Ranks Show for REC Group REC420AA 72 XV?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for REC Group REC420AA 72 XV by REC Group.

Rank #7,910 / 21,677

Top 37.8% STC Output

420.0 W STC (+35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,981

20.39% Aperture Efficiency

Power density 203.9 W/m2 (0.48 percentage points above 19.91% CEC median). PTC/STC ratio: 94.7% (rank #2,085).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 56.82 V at -10 C (568.2 V string) and 58.05 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,400 W STC

Occupies 41.2 m2 (443 sq ft) producing 7,958 W PTC; NEC 690.8 OCPD floor is 15.91 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 52.5 * (1 + (-0.235/100) * (-10 - 25)) = 56.82 V | OCPD = 1.56 * 10.2 = 15.91 A

Inputs from CEC Modules.csv for REC Group REC420AA 72 XV: Voc=52.5 V, beta_Voc=-0.235%/C, Isc=10.2 A, STC=420.0 W, Area=2.06 m2.

Result: 10 panels max on 600 V (568.2 V); 20 panels for 8 kW (443 sq ft).

What Are the Published CEC Specifications for REC Group REC420AA 72 XV?

Laboratory test ratings recorded for REC Group REC420AA 72 XV (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC420AA 72 XV.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 420.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 397.9 W (94.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 52.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.2 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 44.5 V / 9.45 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.235 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.39% (2.06 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC420AA 72 XV Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (443 sq ft at 8 kW), and estimated Year-1 electric bill offset for REC Group REC420AA 72 XV.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.3 kW 333 sq ft $1,577 $2,666
8 kW Class 20 8.4 kW 443 sq ft $2,102 $3,555
10 kW Class 24 10.08 kW 532 sq ft $2,523 $4,266

How Many REC Group REC420AA 72 XV Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for REC Group REC420AA 72 XV (beta_Voc -0.235%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=52.5V and beta_Voc=-0.235%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 58.05 V 10 panels 580.5 V 17 panels
-10 C (14 F) 56.82 V 10 panels 568.2 V 17 panels
0 C (32 F) 55.58 V 10 panels 555.8 V 17 panels
25 C (77 F STC) 52.5 V 11 panels 577.5 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC420AA 72 XV?

Closest cross-brand CEC competitors to REC Group REC420AA 72 XV matched near 420.0 W STC and 52.5 V Voc, led by CSI Solar Co Ltd CS1Y-410MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS1Y-410MS
CSI Solar Co Ltd
410.0 W -10.0 W 52.7 V 21.03% 94.1%
DualSun SAS DualSun 420M-144-01
DualSun SAS
420.0 W Tie (0 W) 48.8 V 19.44% 93.8%
Auxin Solar AXNG1M410B
Auxin Solar
410.0 W -10.0 W 49.47 V 20.92% 93.4%
Auxin Solar AXNG1M410W
Auxin Solar
410.0 W -10.0 W 49.47 V 20.92% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC420AA 72 XV?

Evaluate REC Group REC420AA 72 XV (420.0 W STC, 52.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC420AA 72 XV reaches 58.05 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 443 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (443 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of REC Group REC420AA 72 XV carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC420AA 72 XV 8 kW Residential Fit

Needs 20 modules (443 sq ft) with a 20 A string OCPD, offsetting ~$2,102/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS1Y-410MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 397.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC420AA 72 XV by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for REC Group REC420AA 72 XV?

Multiplying REC Group REC420AA 72 XV's 10.2 A short-circuit current by 1.56 equals 15.91 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can REC Group REC420AA 72 XV pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 56.82 V cold Voc at 14 F and handles 10.2 A Isc; string inverters cap REC Group REC420AA 72 XV at 10 panels on 600 V.

Is REC Group REC420AA 72 XV eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC420AA 72 XV rely on utility bill offset (~$2,102/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.