REC Group REC380AA is a 380.0 W STC (361.5 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 22.49% efficiency, 44.3 V Voc at 25 C, and 47.96 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 380.0 W
- PTC Wattage
- 361.5 W
- Voc @ 25C
- 44.3 V
- Efficiency
- 22.49%
How Does REC Group REC380AA Compare Against Peer CEC Listings?
Engineering position of REC Group REC380AA (380.0 W STC) vs. CSI Solar Co Ltd CS3N-385MS {Blk} across 5,889 CEC Mono-c-Si solar modules.
Ranking #11,043 across 21,677 CEC solar panels (below all-CEC median; higher than 47.6% of peers), REC Group REC380AA operates as a compact residential or specialty off-grid module sitting 30.0 W below the 410.0 W Mono-c-Si median. Mid-range 44.3 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F. With strong 95.1% PTC-to-STC heat retention (#713 of 21,677), 22 panels occupy 400 sq ft and offset roughly $2,092/yr at average US rates (or $3,538/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does REC Group REC380AA Fall Across Listed CEC Models?
Plots REC Group REC380AA at 380.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define REC Group REC380AA?
Benchmarks REC Group REC380AA on STC wattage, thermal PTC/STC retention, and 22.49 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for REC Group REC380AA?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for REC Group REC380AA by REC Group.
380.0 W STC · Higher Than 47.6%
380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.49% Aperture Efficiency
Power density 224.9 W/m2 (2.58 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 47.96 V at -10 C (575.5 V string) and 49.0 V at -20 C (12 max).
22 Panels = 8,360 W STC
Occupies 37.2 m2 (400 sq ft) producing 7,953 W PTC; NEC 690.8 OCPD floor is 16.55 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.3 * (1 + (-0.236/100) * (-10 - 25)) = 47.96 V | OCPD = 1.56 * 10.61 = 16.55 A
Inputs from CEC Modules.csv for REC Group REC380AA: Voc=44.3 V, beta_Voc=-0.236%/C, Isc=10.61 A, STC=380.0 W, Area=1.69 m2.
Result: 12 panels max on 600 V (575.5 V); 22 panels for 8 kW (400 sq ft).
What Are the Published CEC Specifications for REC Group REC380AA?
Laboratory test ratings recorded for REC Group REC380AA (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 361.5 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.61 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.1 V / 9.98 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.236 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.49% (1.69 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many REC Group REC380AA Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (400 sq ft at 8 kW), and estimated Year-1 electric bill offset for REC Group REC380AA.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.08 kW | 291 sq ft | $1,522 | $2,573 |
| 8 kW Class | 22 | 8.36 kW | 400 sq ft | $2,092 | $3,538 |
| 10 kW Class | 27 | 10.26 kW | 491 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This REC Group Series?
Sibling wattage bins and frame colors grouped with REC Group REC380AA under REC Group to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| REC Group REC375AA | 375.0 W | 356.6 W | 44.2 V | 37.8 V | 22.19% |
| REC Group REC375AA Black | 375.0 W | 355.6 W | 44.2 V | 37.8 V | 22.19% |
| REC Group REC380AA | 380.0 W | 361.5 W | 44.3 V | 38.1 V | 22.49% |
| REC Group REC380AA Black | 380.0 W | 360.4 W | 44.3 V | 38.1 V | 22.49% |
| REC Group REC385AA | 385.0 W | 366.4 W | 44.4 V | 38.4 V | 22.78% |
How Many REC Group REC380AA Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for REC Group REC380AA (beta_Voc -0.236%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 49.0 V | 12 panels | 588.0 V | 20 panels |
| -10 C (14 F) | 47.96 V | 12 panels | 575.5 V | 20 panels |
| 0 C (32 F) | 46.91 V | 12 panels | 562.9 V | 21 panels |
| 25 C (77 F STC) | 44.3 V | 13 panels | 575.9 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to REC Group REC380AA?
Closest cross-brand CEC competitors to REC Group REC380AA matched near 380.0 W STC and 44.3 V Voc, led by CSI Solar Co Ltd CS3N-385MS {Blk}.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3N-385MS {Blk} CSI Solar Co Ltd |
385.0 W | +5.0 W | 43.9 V | 19.54% | 93.4% |
| CSI Solar Co Ltd CS3N-385MS {Wht} CSI Solar Co Ltd |
385.0 W | +5.0 W | 43.9 V | 19.54% | 93.4% |
| CSI Solar Co Ltd CS6XH-375M CSI Solar Co Ltd |
375.0 W | -5.0 W | 45.6 V | 20.27% | 93.0% |
| EMMVEE Photovoltaic Power Private Limited E385M72-B EMMVEE Photovoltaic Power Private Limited |
385.0 W | +5.0 W | 45.9 V | 19.32% | 91.5% |
What Are the Design Limits and Best-Fit Uses for REC Group REC380AA?
Evaluate REC Group REC380AA (380.0 W STC, 44.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), REC Group REC380AA reaches 49.0 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 400 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (400 sq ft).
- 2026 tax credit baseline: cash residential installs of REC Group REC380AA carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
REC Group REC380AA 8 kW Residential Fit
Needs 22 modules (400 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS3N-385MS {Blk}.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 361.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for REC Group REC380AA by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.
How many REC Group REC380AA panels fit on a 600 V winter solar string?
At -10 C (14 F), REC Group REC380AA cold Voc rises from 44.3 V to 47.96 V (beta_Voc -0.236%/C), capping a 600 V string at 12 panels (575.5 V).
How much roof area does an 8 kW array of REC Group REC380AA need?
An 8 kW DC system uses 22 REC Group REC380AA modules (8,360 W STC / 7,953 W PTC), covering roughly 400 sq ft and saving ~$2,092/yr at 18.54 c/kWh.
How does REC Group REC380AA compare against CSI Solar Co Ltd CS3N-385MS {Blk}?
REC Group REC380AA outputs 380.0 W STC (44.3 V Voc, rank #11,043 of 21,677), while CSI Solar Co Ltd CS3N-385MS {Blk} delivers 385.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)