Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC370NP 72 is a 370.0 W STC (345.5 W PTC) Mono-c-Si solar module ranking #11,697 of 21,677 CEC listings (below all-CEC median; higher than 44.4% of peers). It delivers 19.0% efficiency, 47.7 V Voc at 25 C, and 52.14 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
370.0 W
PTC Wattage
345.5 W
Voc @ 25C
47.7 V
Efficiency
19.0%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC370NP 72 Compare Against Peer CEC Listings?

How REC Group REC Group REC370NP 72 handles rooftop heat (345.5 W PTC), 8 kW sizing, and cold winter string voltage.

REC Group builds the REC Group REC370NP 72 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 190.0 W/m2 (0.91 percentage points below 19.91% CEC median). Compared against CertainTeed CT370M00-04 (370.0 W), this model holds strong 93.4% PTC-to-STC heat retention (#7,716 of 21,677). Mid-range 47.7 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 15.85 A overcurrent floor served by a 20 A breaker.

Where Does REC Group REC370NP 72 Fall Across Listed CEC Models?

Where REC Group REC370NP 72 (370.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC370NP 72 (370.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC370NP: 370.0 W

What Dataset Percentiles Define REC Group REC370NP 72?

Percentile placement of REC Group REC370NP 72 across power density (190.0 W/m2), thermal retention, and nameplate STC wattage.

REC Group REC370NP 72 Engineering BenchmarksPercentile comparison of REC Group REC370NP 72 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage370.0 WPTC/STC Retention93.4%Module Efficiency19.0%

What Do the Dataset Ranks Show for REC Group REC370NP 72?

Four critical engineering numbers homeowners and solar installers check first when reviewing REC Group REC370NP 72 specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #11,697 / 21,677

370.0 W STC · Higher Than 44.4%

370.0 W STC (-15.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #13,454

19.0% Aperture Efficiency

Power density 190.0 W/m2 (0.91 percentage points below 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.14 V at -10 C (573.5 V string) and 53.41 V at -20 C (11 max).

8 kW Reference Array

22 Panels = 8,140 W STC

Occupies 42.8 m2 (461 sq ft) producing 7,601 W PTC; NEC 690.8 OCPD floor is 15.85 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.7 * (1 + (-0.266/100) * (-10 - 25)) = 52.14 V | OCPD = 1.56 * 10.16 = 15.85 A

Inputs from CEC Modules.csv for REC Group REC370NP 72: Voc=47.7 V, beta_Voc=-0.266%/C, Isc=10.16 A, STC=370.0 W, Area=1.947 m2.

Result: 11 panels max on 600 V (573.5 V); 22 panels for 8 kW (461 sq ft).

What Are the Published CEC Specifications for REC Group REC370NP 72?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for REC Group REC370NP 72.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC370NP 72.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 370.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 345.5 W (93.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.16 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.3 V / 9.42 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.0% (1.947 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC370NP 72 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using REC Group REC370NP 72 (370.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.29 kW 356 sq ft $1,574 $2,662
8 kW Class 22 8.14 kW 461 sq ft $2,037 $3,445
10 kW Class 28 10.36 kW 587 sq ft $2,593 $4,385

Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

All closely matched REC Group wattages and cosmetic trims sharing the REC Group REC370NP 72 architecture. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Sibling CEC listings grouped into the REC Group REC370NP 72 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
REC Group REC365NP 72 365.0 W 340.7 W 47.4 V 39.1 V 18.75%
REC Group REC370NP 72 370.0 W 345.5 W 47.7 V 39.3 V 19.0%

How Many REC Group REC370NP 72 Modules Fit in a Cold-Weather String?

Maximum series module counts for REC Group REC370NP 72 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=47.7V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.41 V 11 panels 587.5 V 18 panels
-10 C (14 F) 52.14 V 11 panels 573.5 V 19 panels
0 C (32 F) 50.87 V 11 panels 559.6 V 19 panels
25 C (77 F STC) 47.7 V 12 panels 572.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC370NP 72?

Alternative CEC solar modules from competing brands near REC Group REC370NP 72 (370.0 W), including CertainTeed CT370M00-04. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CertainTeed CT370M00-04
CertainTeed
370.0 W Tie (0 W) 47.9 V 19.66% 93.2%
Bluesun Solar Energy Tech CoLtd BSM370M-72
Bluesun Solar Energy Tech CoLtd
370.0 W Tie (0 W) 48.23 V 19.07% 91.9%
Caterpillar Inc PVC370MP03H
Caterpillar Inc
370.0 W Tie (0 W) 48.6 V 19.11% 94.1%
CertainTeed CT365M10-02
CertainTeed
365.0 W -5.0 W 47.66 V 19.39% 91.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC370NP 72?

Evaluate REC Group REC370NP 72 (370.0 W STC, 47.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC370NP 72 reaches 53.41 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 22 panels for an 8 kW build require 461 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (461 sq ft).
  • 2026 tax credit baseline: cash residential installs of REC Group REC370NP 72 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC370NP 72 8 kW Residential Fit

Needs 22 modules (461 sq ft) with a 20 A string OCPD, offsetting ~$2,037/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CertainTeed CT370M00-04.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 345.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC370NP 72 by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for REC Group REC370NP 72?

Multiplying REC Group REC370NP 72's 10.16 A short-circuit current by 1.56 equals 15.85 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can REC Group REC370NP 72 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.14 V cold Voc at 14 F and handles 10.16 A Isc; string inverters cap REC Group REC370NP 72 at 11 panels on 600 V.

Is REC Group REC370NP 72 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC370NP 72 rely on utility bill offset (~$2,037/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.