Manufacturer: REC Group Registry: CEC Verified Engineering Specification

REC Group REC345AA is a 345.0 W STC (327.5 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 20.54% efficiency, 43.4 V Voc at 25 C, and 47.06 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
345.0 W
PTC Wattage
327.5 W
Voc @ 25C
43.4 V
Efficiency
20.54%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does REC Group REC345AA Compare Against Peer CEC Listings?

How REC Group REC Group REC345AA handles rooftop heat (327.5 W PTC), 8 kW sizing, and cold winter string voltage.

REC Group builds the REC Group REC345AA (Mono-c-Si) as a compact residential or specialty off-grid module delivering 205.4 W/m2 (0.63 percentage points above 19.91% CEC median). Compared against CSI Solar Co Ltd CS6XH-345M (345.0 W), this model holds strong 94.9% PTC-to-STC heat retention (#1,466 of 21,677). Mid-range 43.4 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 15.79 A overcurrent floor served by a 20 A breaker.

Where Does REC Group REC345AA Fall Across Listed CEC Models?

Where REC Group REC345AA (345.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where REC Group REC345AA (345.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCREC Group REC345AA: 345.0 W

What Dataset Percentiles Define REC Group REC345AA?

Percentile placement of REC Group REC345AA across power density (205.4 W/m2), thermal retention, and nameplate STC wattage.

REC Group REC345AA Engineering BenchmarksPercentile comparison of REC Group REC345AA wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage345.0 WPTC/STC Retention94.9%Module Efficiency20.54%

What Do the Dataset Ranks Show for REC Group REC345AA?

Four critical engineering numbers homeowners and solar installers check first when reviewing REC Group REC345AA specifications. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Rank #13,309 / 21,677

345.0 W STC · Higher Than 37.4%

345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,364

20.54% Aperture Efficiency

Power density 205.4 W/m2 (0.63 percentage points above 19.91% CEC median). PTC/STC ratio: 94.9% (rank #1,466).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 47.06 V at -10 C (564.7 V string) and 48.11 V at -20 C (12 max).

8 kW Reference Array

24 Panels = 8,280 W STC

Occupies 40.3 m2 (434 sq ft) producing 7,860 W PTC; NEC 690.8 OCPD floor is 15.79 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.4 * (1 + (-0.241/100) * (-10 - 25)) = 47.06 V | OCPD = 1.56 * 10.12 = 15.79 A

Inputs from CEC Modules.csv for REC Group REC345AA: Voc=43.4 V, beta_Voc=-0.241%/C, Isc=10.12 A, STC=345.0 W, Area=1.68 m2.

Result: 12 panels max on 600 V (564.7 V); 24 panels for 8 kW (434 sq ft).

What Are the Published CEC Specifications for REC Group REC345AA?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for REC Group REC345AA.

Official California Energy Commission (NREL SAM) test parameters for REC Group REC345AA.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 345.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 327.5 W (94.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.12 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.7 V / 9.39 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.241 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.54% (1.68 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many REC Group REC345AA Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using REC Group REC345AA (345.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.21 kW 326 sq ft $1,554 $2,628
8 kW Class 24 8.28 kW 434 sq ft $2,072 $3,504
10 kW Class 29 10.01 kW 524 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This REC Group Series?

All closely matched REC Group wattages and cosmetic trims sharing the REC Group REC345AA architecture. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the REC Group REC345AA wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
REC Group REC340AA 340.0 W 322.7 W 43.1 V 36.4 V 20.24%
REC Group REC340AA Black 340.0 W 321.0 W 43.1 V 36.4 V 20.12%
REC Group REC345AA 345.0 W 327.5 W 43.4 V 36.7 V 20.54%
REC Group REC345AA Black 345.0 W 325.8 W 43.4 V 36.7 V 20.41%

How Many REC Group REC345AA Modules Fit in a Cold-Weather String?

Maximum series module counts for REC Group REC345AA from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=43.4V and beta_Voc=-0.241%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 48.11 V 12 panels 577.3 V 20 panels
-10 C (14 F) 47.06 V 12 panels 564.7 V 21 panels
0 C (32 F) 46.01 V 13 panels 598.1 V 21 panels
25 C (77 F STC) 43.4 V 13 panels 564.2 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to REC Group REC345AA?

Alternative CEC solar modules from competing brands near REC Group REC345AA (345.0 W), including CSI Solar Co Ltd CS6XH-345M.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS6XH-345M
CSI Solar Co Ltd
345.0 W Tie (0 W) 44.4 V 18.65% 92.8%
CSI Solar Co Ltd CS1H-335MS
CSI Solar Co Ltd
335.0 W -10.0 W 43.6 V 20.55% 93.4%
CSI Solar Co Ltd CS6XH-335P
CSI Solar Co Ltd
335.0 W -10.0 W 43.0 V 18.11% 93.0%
Caterpillar Inc PVC345MP03HA
Caterpillar Inc
345.0 W Tie (0 W) 40.2 V 19.49% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for REC Group REC345AA?

Evaluate REC Group REC345AA (345.0 W STC, 43.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), REC Group REC345AA reaches 48.11 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 434 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (434 sq ft).
  • 2026 tax credit baseline: cash residential installs of REC Group REC345AA carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

REC Group REC345AA 8 kW Residential Fit

Needs 24 modules (434 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS6XH-345M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 327.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for REC Group REC345AA by REC Group grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for REC Group REC345AA?

Multiplying REC Group REC345AA's 10.12 A short-circuit current by 1.56 equals 15.79 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can REC Group REC345AA pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 47.06 V cold Voc at 14 F and handles 10.12 A Isc; string inverters cap REC Group REC345AA at 12 panels on 600 V.

Is REC Group REC345AA eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of REC Group REC345AA rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?